Standardized structural magnetic resonance imaging in multicentre studies using quantitative T1 and T2 imaging at 1.5 T.

The ability to acquire MRI data with consistent tissue contrast at multiple time points, and/or across different imaging centres has become increasingly important as the number of large longitudinal and multicentre studies has grown. Here, the use of quantitative magnetic resonance relaxation times...

Πλήρης περιγραφή

Λεπτομέρειες βιβλιογραφικής εγγραφής
Κύριοι συγγραφείς: Deoni, S, Williams, S, Jezzard, P, Suckling, J, Murphy, D, Jones, D
Μορφή: Journal article
Γλώσσα:English
Έκδοση: 2008
_version_ 1826304421383897088
author Deoni, S
Williams, S
Jezzard, P
Suckling, J
Murphy, D
Jones, D
author_facet Deoni, S
Williams, S
Jezzard, P
Suckling, J
Murphy, D
Jones, D
author_sort Deoni, S
collection OXFORD
description The ability to acquire MRI data with consistent tissue contrast at multiple time points, and/or across different imaging centres has become increasingly important as the number of large longitudinal and multicentre studies has grown. Here, the use of quantitative magnetic resonance relaxation times measurement, or, voxel-wise determination of the intrinsic longitudinal and transverse relaxation times, T1 and T2 respectively, for standardizing the structural imaging component of such studies is reported. To demonstrate the ability to standardize across multiple time-points and imaging centres, T1 and T2 maps of seven healthy volunteers were acquired using the rapid DESPOT1 and DESPOT2 (driven equilibrium single pulse observation of T1 and T2) mapping techniques at three centres across the United Kingdom (each centre utilizing scanners from competing manufacturers and/or with varying gradient performance). An average coefficient of variation of the estimates of T1 and T2 was found to be approximately 6.5% and 8%, respectively, across the three centres and comparable to that achieved between repeated imaging sessions performed at the same centre. With a total combined imaging time of less than 12 min for whole-brain approximately 1.2 mm isotropic voxel T1 and T2 maps, quantitative voxel-wise T1 and T2 mapping represents an attractive and easy-to-implement approach for signal intensity standardization and normalization. Further, as T1 and T2 are related to tissue microstructure and biochemistry, quantitative images provide additional diagnostic information that can be compared between patient and control populations, for example through voxel-based analysis techniques.
first_indexed 2024-03-07T06:17:33Z
format Journal article
id oxford-uuid:f19b84cf-b06c-4a99-8e5c-4b7d94a0cc7a
institution University of Oxford
language English
last_indexed 2024-03-07T06:17:33Z
publishDate 2008
record_format dspace
spelling oxford-uuid:f19b84cf-b06c-4a99-8e5c-4b7d94a0cc7a2022-03-27T11:57:20ZStandardized structural magnetic resonance imaging in multicentre studies using quantitative T1 and T2 imaging at 1.5 T.Journal articlehttp://purl.org/coar/resource_type/c_dcae04bcuuid:f19b84cf-b06c-4a99-8e5c-4b7d94a0cc7aEnglishSymplectic Elements at Oxford2008Deoni, SWilliams, SJezzard, PSuckling, JMurphy, DJones, DThe ability to acquire MRI data with consistent tissue contrast at multiple time points, and/or across different imaging centres has become increasingly important as the number of large longitudinal and multicentre studies has grown. Here, the use of quantitative magnetic resonance relaxation times measurement, or, voxel-wise determination of the intrinsic longitudinal and transverse relaxation times, T1 and T2 respectively, for standardizing the structural imaging component of such studies is reported. To demonstrate the ability to standardize across multiple time-points and imaging centres, T1 and T2 maps of seven healthy volunteers were acquired using the rapid DESPOT1 and DESPOT2 (driven equilibrium single pulse observation of T1 and T2) mapping techniques at three centres across the United Kingdom (each centre utilizing scanners from competing manufacturers and/or with varying gradient performance). An average coefficient of variation of the estimates of T1 and T2 was found to be approximately 6.5% and 8%, respectively, across the three centres and comparable to that achieved between repeated imaging sessions performed at the same centre. With a total combined imaging time of less than 12 min for whole-brain approximately 1.2 mm isotropic voxel T1 and T2 maps, quantitative voxel-wise T1 and T2 mapping represents an attractive and easy-to-implement approach for signal intensity standardization and normalization. Further, as T1 and T2 are related to tissue microstructure and biochemistry, quantitative images provide additional diagnostic information that can be compared between patient and control populations, for example through voxel-based analysis techniques.
spellingShingle Deoni, S
Williams, S
Jezzard, P
Suckling, J
Murphy, D
Jones, D
Standardized structural magnetic resonance imaging in multicentre studies using quantitative T1 and T2 imaging at 1.5 T.
title Standardized structural magnetic resonance imaging in multicentre studies using quantitative T1 and T2 imaging at 1.5 T.
title_full Standardized structural magnetic resonance imaging in multicentre studies using quantitative T1 and T2 imaging at 1.5 T.
title_fullStr Standardized structural magnetic resonance imaging in multicentre studies using quantitative T1 and T2 imaging at 1.5 T.
title_full_unstemmed Standardized structural magnetic resonance imaging in multicentre studies using quantitative T1 and T2 imaging at 1.5 T.
title_short Standardized structural magnetic resonance imaging in multicentre studies using quantitative T1 and T2 imaging at 1.5 T.
title_sort standardized structural magnetic resonance imaging in multicentre studies using quantitative t1 and t2 imaging at 1 5 t
work_keys_str_mv AT deonis standardizedstructuralmagneticresonanceimaginginmulticentrestudiesusingquantitativet1andt2imagingat15t
AT williamss standardizedstructuralmagneticresonanceimaginginmulticentrestudiesusingquantitativet1andt2imagingat15t
AT jezzardp standardizedstructuralmagneticresonanceimaginginmulticentrestudiesusingquantitativet1andt2imagingat15t
AT sucklingj standardizedstructuralmagneticresonanceimaginginmulticentrestudiesusingquantitativet1andt2imagingat15t
AT murphyd standardizedstructuralmagneticresonanceimaginginmulticentrestudiesusingquantitativet1andt2imagingat15t
AT jonesd standardizedstructuralmagneticresonanceimaginginmulticentrestudiesusingquantitativet1andt2imagingat15t