Compartment-based reconstruction of 3D acquisition-weighted 31P cardiac magnetic resonance spectroscopic imaging at 7 T: a reproducibility study

Even at 7 T, cardiac 31P magnetic resonance spectroscopic imaging (MRSI) is fundamentally limited by low signal-to-noise ratio (SNR), leading to long scan times and poor temporal and spatial resolutions. Compartment-based reconstruction algorithms such as magnetic resonance spectroscopy with linear...

সম্পূর্ণ বিবরণ

গ্রন্থ-পঞ্জীর বিবরন
প্রধান লেখক: Tyler, A, Ellis, J, Lau, JYC, Miller, JJ, Bottomley, PA, Rodgers, CT, Tyler, DJ, Valkovič, L
বিন্যাস: Journal article
ভাষা:English
প্রকাশিত: Wiley 2023
_version_ 1826311274396385280
author Tyler, A
Ellis, J
Lau, JYC
Miller, JJ
Bottomley, PA
Rodgers, CT
Tyler, DJ
Valkovič, L
author_facet Tyler, A
Ellis, J
Lau, JYC
Miller, JJ
Bottomley, PA
Rodgers, CT
Tyler, DJ
Valkovič, L
author_sort Tyler, A
collection OXFORD
description Even at 7 T, cardiac 31P magnetic resonance spectroscopic imaging (MRSI) is fundamentally limited by low signal-to-noise ratio (SNR), leading to long scan times and poor temporal and spatial resolutions. Compartment-based reconstruction algorithms such as magnetic resonance spectroscopy with linear algebraic modeling (SLAM) and spectral localization by imaging (SLIM) may improve SNR or reduce scan time without changes to acquisition. Here, we compare the repeatability and SNR performance of these compartment-based methods, applied to three different acquisition schemes at 7 T. Twelve healthy volunteers were scanned twice. Each scan session consisted of a 6.5-min 3D acquisition-weighted (AW) cardiac 31P phase encode-based MRSI acquisition and two 6.5-min truncated k-space acquisitions with increased averaging (4 × 4 × 4 central k-space phase encodes and fractional SLAM [fSLAM] optimized k-space phase encodes). Spectra were reconstructed using (i) AW Fourier reconstruction; (ii) AW SLAM; (iii) AW SLIM; (iv) 4 × 4 × 4 SLAM; (v) 4 × 4 × 4 SLIM; and (vi) fSLAM acquisition–reconstruction combinations. The phosphocreatine-to-adenosine triphosphate (PCr/ATP) ratio, the PCr SNR, and spatial response functions were computed, in addition to coefficients of reproducibility and variability. Using the compartment-based reconstruction algorithms with the AW 31P acquisition resulted in a significant increase in SNR compared with previously published Fourier-based MRSI reconstruction methods while maintaining the measured PCr/ATP ratio and improving interscan reproducibility. The alternative acquisition strategies with truncated k-space performed no better than the common AW approach. Compartment-based spectroscopy approaches provide an attractive reconstruction method for cardiac 31P spectroscopy at 7 T, improving reproducibility and SNR without the need for a dedicated k-space sampling strategy.
first_indexed 2024-03-07T08:05:55Z
format Journal article
id oxford-uuid:f5a1f411-844b-4fdc-ab8f-41a2a72bedb6
institution University of Oxford
language English
last_indexed 2024-03-07T08:05:55Z
publishDate 2023
publisher Wiley
record_format dspace
spelling oxford-uuid:f5a1f411-844b-4fdc-ab8f-41a2a72bedb62023-10-26T11:20:39ZCompartment-based reconstruction of 3D acquisition-weighted 31P cardiac magnetic resonance spectroscopic imaging at 7 T: a reproducibility studyJournal articlehttp://purl.org/coar/resource_type/c_dcae04bcuuid:f5a1f411-844b-4fdc-ab8f-41a2a72bedb6EnglishSymplectic ElementsWiley2023Tyler, AEllis, JLau, JYCMiller, JJBottomley, PARodgers, CTTyler, DJValkovič, LEven at 7 T, cardiac 31P magnetic resonance spectroscopic imaging (MRSI) is fundamentally limited by low signal-to-noise ratio (SNR), leading to long scan times and poor temporal and spatial resolutions. Compartment-based reconstruction algorithms such as magnetic resonance spectroscopy with linear algebraic modeling (SLAM) and spectral localization by imaging (SLIM) may improve SNR or reduce scan time without changes to acquisition. Here, we compare the repeatability and SNR performance of these compartment-based methods, applied to three different acquisition schemes at 7 T. Twelve healthy volunteers were scanned twice. Each scan session consisted of a 6.5-min 3D acquisition-weighted (AW) cardiac 31P phase encode-based MRSI acquisition and two 6.5-min truncated k-space acquisitions with increased averaging (4 × 4 × 4 central k-space phase encodes and fractional SLAM [fSLAM] optimized k-space phase encodes). Spectra were reconstructed using (i) AW Fourier reconstruction; (ii) AW SLAM; (iii) AW SLIM; (iv) 4 × 4 × 4 SLAM; (v) 4 × 4 × 4 SLIM; and (vi) fSLAM acquisition–reconstruction combinations. The phosphocreatine-to-adenosine triphosphate (PCr/ATP) ratio, the PCr SNR, and spatial response functions were computed, in addition to coefficients of reproducibility and variability. Using the compartment-based reconstruction algorithms with the AW 31P acquisition resulted in a significant increase in SNR compared with previously published Fourier-based MRSI reconstruction methods while maintaining the measured PCr/ATP ratio and improving interscan reproducibility. The alternative acquisition strategies with truncated k-space performed no better than the common AW approach. Compartment-based spectroscopy approaches provide an attractive reconstruction method for cardiac 31P spectroscopy at 7 T, improving reproducibility and SNR without the need for a dedicated k-space sampling strategy.
spellingShingle Tyler, A
Ellis, J
Lau, JYC
Miller, JJ
Bottomley, PA
Rodgers, CT
Tyler, DJ
Valkovič, L
Compartment-based reconstruction of 3D acquisition-weighted 31P cardiac magnetic resonance spectroscopic imaging at 7 T: a reproducibility study
title Compartment-based reconstruction of 3D acquisition-weighted 31P cardiac magnetic resonance spectroscopic imaging at 7 T: a reproducibility study
title_full Compartment-based reconstruction of 3D acquisition-weighted 31P cardiac magnetic resonance spectroscopic imaging at 7 T: a reproducibility study
title_fullStr Compartment-based reconstruction of 3D acquisition-weighted 31P cardiac magnetic resonance spectroscopic imaging at 7 T: a reproducibility study
title_full_unstemmed Compartment-based reconstruction of 3D acquisition-weighted 31P cardiac magnetic resonance spectroscopic imaging at 7 T: a reproducibility study
title_short Compartment-based reconstruction of 3D acquisition-weighted 31P cardiac magnetic resonance spectroscopic imaging at 7 T: a reproducibility study
title_sort compartment based reconstruction of 3d acquisition weighted 31p cardiac magnetic resonance spectroscopic imaging at 7 t a reproducibility study
work_keys_str_mv AT tylera compartmentbasedreconstructionof3dacquisitionweighted31pcardiacmagneticresonancespectroscopicimagingat7tareproducibilitystudy
AT ellisj compartmentbasedreconstructionof3dacquisitionweighted31pcardiacmagneticresonancespectroscopicimagingat7tareproducibilitystudy
AT laujyc compartmentbasedreconstructionof3dacquisitionweighted31pcardiacmagneticresonancespectroscopicimagingat7tareproducibilitystudy
AT millerjj compartmentbasedreconstructionof3dacquisitionweighted31pcardiacmagneticresonancespectroscopicimagingat7tareproducibilitystudy
AT bottomleypa compartmentbasedreconstructionof3dacquisitionweighted31pcardiacmagneticresonancespectroscopicimagingat7tareproducibilitystudy
AT rodgersct compartmentbasedreconstructionof3dacquisitionweighted31pcardiacmagneticresonancespectroscopicimagingat7tareproducibilitystudy
AT tylerdj compartmentbasedreconstructionof3dacquisitionweighted31pcardiacmagneticresonancespectroscopicimagingat7tareproducibilitystudy
AT valkovicl compartmentbasedreconstructionof3dacquisitionweighted31pcardiacmagneticresonancespectroscopicimagingat7tareproducibilitystudy