Analysis of porous materials for transpiration cooled heat flux sensor development

The Non-Integer System Identification (NISI) method is an useful tool for the determination of surface heat flux from in-depth temperature data even in transpiration cooled environments. Recently it was demonstrated that in these transpiration cooled environments the surface heat flux can be determi...