Pulse oximetry adoption and oxygen orders at paediatric admission over 7 years in Kenya: a multihospital retrospective cohort study

Objectives To characterise adoption and explore specific clinical and patient factors that might influence pulse oximetry and oxygen use in low-income and middle-income countries (LMICs) over time; to highlight useful considerations for entities working on programmes to improve access to pulse oxime...

Full beskrivning

Bibliografiska uppgifter
Huvudupphovsmän: Tuti, T, Aluvaala, J, Akech, S, Agweyu, A, Irimu, G, English, M
Övriga upphovsmän: Clinical Information Network Author Group
Materialtyp: Journal article
Språk:English
Publicerad: BMJ Publishing Group 2021
_version_ 1826306063826157568
author Tuti, T
Aluvaala, J
Akech, S
Agweyu, A
Irimu, G
English, M
author2 Clinical Information Network Author Group
author_facet Clinical Information Network Author Group
Tuti, T
Aluvaala, J
Akech, S
Agweyu, A
Irimu, G
English, M
author_sort Tuti, T
collection OXFORD
description Objectives To characterise adoption and explore specific clinical and patient factors that might influence pulse oximetry and oxygen use in low-income and middle-income countries (LMICs) over time; to highlight useful considerations for entities working on programmes to improve access to pulse oximetry and oxygen. Design A multihospital retrospective cohort study. Settings All admissions (n=132 737) to paediatric wards of 18 purposely selected public hospitals in Kenya that joined a Clinical Information Network (CIN) between March 2014 and December 2020. Outcomes Pulse oximetry use and oxygen prescription on admission; we performed growth-curve modelling to investigate the association of patient factors with study outcomes over time while adjusting for hospital factors. Results Overall, pulse oximetry was used in 48.8% (64 722/132 737) of all admission cases. Use rose on average with each month of participation in the CIN (OR: 1.11, 95% CI 1.05 to 1.18) but patterns of adoption were highly variable across hospitals suggesting important factors at hospital level influence use of pulse oximetry. Of those with pulse oximetry measurement, 7% (4510/64 722) had hypoxaemia (SpO2 <90%). Across the same period, 8.6% (11 428/132 737) had oxygen prescribed but in 87%, pulse oximetry was either not done or the hypoxaemia threshold (SpO2 <90%) was not met. Lower chest-wall indrawing and other respiratory symptoms were associated with pulse oximetry use at admission and were also associated with oxygen prescription in the absence of pulse oximetry or hypoxaemia. Conclusion The adoption of pulse oximetry recommended in international guidelines for assessing children with severe illness has been slow and erratic, reflecting system and organisational weaknesses. Most oxygen orders at admission seem driven by clinical and situational factors other than the presence of hypoxaemia. Programmes aiming to implement pulse oximetry and oxygen systems will likely need a long-term vision to promote adoption, guideline development and adherence and continuously examine impact.
first_indexed 2024-03-07T06:42:15Z
format Journal article
id oxford-uuid:f9b274f2-970b-46f6-a39c-ef44e3404365
institution University of Oxford
language English
last_indexed 2024-03-07T06:42:15Z
publishDate 2021
publisher BMJ Publishing Group
record_format dspace
spelling oxford-uuid:f9b274f2-970b-46f6-a39c-ef44e34043652022-03-27T12:59:51ZPulse oximetry adoption and oxygen orders at paediatric admission over 7 years in Kenya: a multihospital retrospective cohort studyJournal articlehttp://purl.org/coar/resource_type/c_dcae04bcuuid:f9b274f2-970b-46f6-a39c-ef44e3404365EnglishSymplectic ElementsBMJ Publishing Group2021Tuti, TAluvaala, JAkech, SAgweyu, AIrimu, GEnglish, MClinical Information Network Author GroupObjectives To characterise adoption and explore specific clinical and patient factors that might influence pulse oximetry and oxygen use in low-income and middle-income countries (LMICs) over time; to highlight useful considerations for entities working on programmes to improve access to pulse oximetry and oxygen. Design A multihospital retrospective cohort study. Settings All admissions (n=132 737) to paediatric wards of 18 purposely selected public hospitals in Kenya that joined a Clinical Information Network (CIN) between March 2014 and December 2020. Outcomes Pulse oximetry use and oxygen prescription on admission; we performed growth-curve modelling to investigate the association of patient factors with study outcomes over time while adjusting for hospital factors. Results Overall, pulse oximetry was used in 48.8% (64 722/132 737) of all admission cases. Use rose on average with each month of participation in the CIN (OR: 1.11, 95% CI 1.05 to 1.18) but patterns of adoption were highly variable across hospitals suggesting important factors at hospital level influence use of pulse oximetry. Of those with pulse oximetry measurement, 7% (4510/64 722) had hypoxaemia (SpO2 <90%). Across the same period, 8.6% (11 428/132 737) had oxygen prescribed but in 87%, pulse oximetry was either not done or the hypoxaemia threshold (SpO2 <90%) was not met. Lower chest-wall indrawing and other respiratory symptoms were associated with pulse oximetry use at admission and were also associated with oxygen prescription in the absence of pulse oximetry or hypoxaemia. Conclusion The adoption of pulse oximetry recommended in international guidelines for assessing children with severe illness has been slow and erratic, reflecting system and organisational weaknesses. Most oxygen orders at admission seem driven by clinical and situational factors other than the presence of hypoxaemia. Programmes aiming to implement pulse oximetry and oxygen systems will likely need a long-term vision to promote adoption, guideline development and adherence and continuously examine impact.
spellingShingle Tuti, T
Aluvaala, J
Akech, S
Agweyu, A
Irimu, G
English, M
Pulse oximetry adoption and oxygen orders at paediatric admission over 7 years in Kenya: a multihospital retrospective cohort study
title Pulse oximetry adoption and oxygen orders at paediatric admission over 7 years in Kenya: a multihospital retrospective cohort study
title_full Pulse oximetry adoption and oxygen orders at paediatric admission over 7 years in Kenya: a multihospital retrospective cohort study
title_fullStr Pulse oximetry adoption and oxygen orders at paediatric admission over 7 years in Kenya: a multihospital retrospective cohort study
title_full_unstemmed Pulse oximetry adoption and oxygen orders at paediatric admission over 7 years in Kenya: a multihospital retrospective cohort study
title_short Pulse oximetry adoption and oxygen orders at paediatric admission over 7 years in Kenya: a multihospital retrospective cohort study
title_sort pulse oximetry adoption and oxygen orders at paediatric admission over 7 years in kenya a multihospital retrospective cohort study
work_keys_str_mv AT tutit pulseoximetryadoptionandoxygenordersatpaediatricadmissionover7yearsinkenyaamultihospitalretrospectivecohortstudy
AT aluvaalaj pulseoximetryadoptionandoxygenordersatpaediatricadmissionover7yearsinkenyaamultihospitalretrospectivecohortstudy
AT akechs pulseoximetryadoptionandoxygenordersatpaediatricadmissionover7yearsinkenyaamultihospitalretrospectivecohortstudy
AT agweyua pulseoximetryadoptionandoxygenordersatpaediatricadmissionover7yearsinkenyaamultihospitalretrospectivecohortstudy
AT irimug pulseoximetryadoptionandoxygenordersatpaediatricadmissionover7yearsinkenyaamultihospitalretrospectivecohortstudy
AT englishm pulseoximetryadoptionandoxygenordersatpaediatricadmissionover7yearsinkenyaamultihospitalretrospectivecohortstudy