Magnetic targeting of microbubbles against physiologically relevant flow conditions

The localization of microbubbles to a treatment site has been shown to be essential to their effectiveness in therapeutic applications such as targeted drug delivery and gene therapy. A variety of different strategies for achieving localization has been investigated, including biochemical targeting,...

Full description

Bibliographic Details
Main Authors: Owen, J, Rademeyer, P, Chung, D, Cheng, Q, Holroyd, D, Coussios, C, Friend, P, Pankhurst, QA, Stride, E
Format: Journal article
Language:English
Published: Royal Society 2015
_version_ 1797105427057475584
author Owen, J
Rademeyer, P
Chung, D
Cheng, Q
Holroyd, D
Coussios, C
Friend, P
Pankhurst, QA
Stride, E
author_facet Owen, J
Rademeyer, P
Chung, D
Cheng, Q
Holroyd, D
Coussios, C
Friend, P
Pankhurst, QA
Stride, E
author_sort Owen, J
collection OXFORD
description The localization of microbubbles to a treatment site has been shown to be essential to their effectiveness in therapeutic applications such as targeted drug delivery and gene therapy. A variety of different strategies for achieving localization has been investigated, including biochemical targeting, acoustic radiation force, and the incorporation of superparamagnetic nanoparticles into microbubbles to enable their manipulation using an externally applied magnetic field. The third of these strategies has the advantage of concentrating microbubbles in a target region without exposing them to ultrasound, and can be used in conjunction with biochemical targeting to achieve greater specificity. Magnetic microbubbles have been shown to be effective for therapeutic delivery in vitro and in vivo. Whether this technique can be successfully applied in humans however remains an open question. The aim of this study was to determine the range of flow conditions under which targeting could be achieved. In vitro results indicate that magnetic microbubbles can be retained using clinically acceptable magnetic fields, for both the high shear rates (approx. 10(4) s(-1)) found in human arterioles and capillaries, and the high flow rates (approx. 3.5 ml s(-1)) of human arteries. The potential for human in vivo microbubble retention was further demonstrated using a perfused porcine liver model.
first_indexed 2024-03-07T06:47:24Z
format Journal article
id oxford-uuid:fb54173f-12c5-4a7d-be0f-7e936ae43c37
institution University of Oxford
language English
last_indexed 2024-03-07T06:47:24Z
publishDate 2015
publisher Royal Society
record_format dspace
spelling oxford-uuid:fb54173f-12c5-4a7d-be0f-7e936ae43c372022-03-27T13:12:53ZMagnetic targeting of microbubbles against physiologically relevant flow conditionsJournal articlehttp://purl.org/coar/resource_type/c_dcae04bcuuid:fb54173f-12c5-4a7d-be0f-7e936ae43c37EnglishSymplectic Elements at OxfordRoyal Society2015Owen, JRademeyer, PChung, DCheng, QHolroyd, DCoussios, CFriend, PPankhurst, QAStride, EThe localization of microbubbles to a treatment site has been shown to be essential to their effectiveness in therapeutic applications such as targeted drug delivery and gene therapy. A variety of different strategies for achieving localization has been investigated, including biochemical targeting, acoustic radiation force, and the incorporation of superparamagnetic nanoparticles into microbubbles to enable their manipulation using an externally applied magnetic field. The third of these strategies has the advantage of concentrating microbubbles in a target region without exposing them to ultrasound, and can be used in conjunction with biochemical targeting to achieve greater specificity. Magnetic microbubbles have been shown to be effective for therapeutic delivery in vitro and in vivo. Whether this technique can be successfully applied in humans however remains an open question. The aim of this study was to determine the range of flow conditions under which targeting could be achieved. In vitro results indicate that magnetic microbubbles can be retained using clinically acceptable magnetic fields, for both the high shear rates (approx. 10(4) s(-1)) found in human arterioles and capillaries, and the high flow rates (approx. 3.5 ml s(-1)) of human arteries. The potential for human in vivo microbubble retention was further demonstrated using a perfused porcine liver model.
spellingShingle Owen, J
Rademeyer, P
Chung, D
Cheng, Q
Holroyd, D
Coussios, C
Friend, P
Pankhurst, QA
Stride, E
Magnetic targeting of microbubbles against physiologically relevant flow conditions
title Magnetic targeting of microbubbles against physiologically relevant flow conditions
title_full Magnetic targeting of microbubbles against physiologically relevant flow conditions
title_fullStr Magnetic targeting of microbubbles against physiologically relevant flow conditions
title_full_unstemmed Magnetic targeting of microbubbles against physiologically relevant flow conditions
title_short Magnetic targeting of microbubbles against physiologically relevant flow conditions
title_sort magnetic targeting of microbubbles against physiologically relevant flow conditions
work_keys_str_mv AT owenj magnetictargetingofmicrobubblesagainstphysiologicallyrelevantflowconditions
AT rademeyerp magnetictargetingofmicrobubblesagainstphysiologicallyrelevantflowconditions
AT chungd magnetictargetingofmicrobubblesagainstphysiologicallyrelevantflowconditions
AT chengq magnetictargetingofmicrobubblesagainstphysiologicallyrelevantflowconditions
AT holroydd magnetictargetingofmicrobubblesagainstphysiologicallyrelevantflowconditions
AT coussiosc magnetictargetingofmicrobubblesagainstphysiologicallyrelevantflowconditions
AT friendp magnetictargetingofmicrobubblesagainstphysiologicallyrelevantflowconditions
AT pankhurstqa magnetictargetingofmicrobubblesagainstphysiologicallyrelevantflowconditions
AT stridee magnetictargetingofmicrobubblesagainstphysiologicallyrelevantflowconditions