On the mechanical behaviour of PEEK and HA cranial implants under impact loading

The human head can be subjected to numerous impact loadings such as those produced by a fall or during sport activities. These accidents can result in skull fracture and in some complex cases, part of the skull may need to be replaced by a biomedical implant. Even when the skull is not damaged, such...

詳細記述

書誌詳細
主要な著者: Garcia-Gonzalez, D, Jayaratnam, J, Sotiropoulos, S, Yoon, S, Cook, J, Siviour, C, Arias, A, Jerusalem, A
フォーマット: Journal article
出版事項: Elsevier 2017
_version_ 1826306468040671232
author Garcia-Gonzalez, D
Jayaratnam, J
Sotiropoulos, S
Yoon, S
Cook, J
Siviour, C
Arias, A
Jerusalem, A
author_facet Garcia-Gonzalez, D
Jayaratnam, J
Sotiropoulos, S
Yoon, S
Cook, J
Siviour, C
Arias, A
Jerusalem, A
author_sort Garcia-Gonzalez, D
collection OXFORD
description The human head can be subjected to numerous impact loadings such as those produced by a fall or during sport activities. These accidents can result in skull fracture and in some complex cases, part of the skull may need to be replaced by a biomedical implant. Even when the skull is not damaged, such accidents can result in brain swelling treated by decompressive craniectomy. Usually, after recovery, the part of the skull that has been removed is replaced by a prosthesis. In such situations, a numerical tool able to analyse the choice of prosthesis material depending on the patient's specific activity has the potential to be extremely useful for clinicians. The work proposed here focuses on the development and use of a numerical model for the analysis of cranial implants under impact conditions. In particular, two main biomaterials commonly employed for this kind of prosthesis are polyether-ether-ketone (PEEK) and macroporous hydroxyapatite (HA). In order to study the suitability of these implants, a finite element head model comprising scalp, skull, cerebral falx, cerebrospinal fluid and brain tissues, with a cranial implant replacing part of the skull has been developed from magnetic resonance imaging data. The human tissues and these two biocompatible materials have been independently studied and constitutive models for both are provided here. A numerical model of the human head under impact loading is then implemented and validated, and a numerical comparison of the mechanical impact response of PEEK and HA implants is presented. This comparison was carried out in terms of the effectiveness of both implants in ensuring structural integrity and preventing traumatic brain injury. The results obtained in this work highlight the need to take into account environmental mechanical considerations to select the optimal implant depending on the specific patient: whereas HA implants present attractive biointegration properties, PEEK implant can potentially be a much more appropriate choice in a demanding mechanical life style. Finally, a novel methodology is proposed to assess the need for further clinical evaluation in case of impact for both implants over a large range of impact conditions.
first_indexed 2024-03-07T06:48:24Z
format Journal article
id oxford-uuid:fba54983-a4bd-4f5e-b1a8-3794f2334fcb
institution University of Oxford
last_indexed 2024-03-07T06:48:24Z
publishDate 2017
publisher Elsevier
record_format dspace
spelling oxford-uuid:fba54983-a4bd-4f5e-b1a8-3794f2334fcb2022-03-27T13:15:21ZOn the mechanical behaviour of PEEK and HA cranial implants under impact loadingJournal articlehttp://purl.org/coar/resource_type/c_dcae04bcuuid:fba54983-a4bd-4f5e-b1a8-3794f2334fcbSymplectic Elements at OxfordElsevier2017Garcia-Gonzalez, DJayaratnam, JSotiropoulos, SYoon, SCook, JSiviour, CArias, AJerusalem, AThe human head can be subjected to numerous impact loadings such as those produced by a fall or during sport activities. These accidents can result in skull fracture and in some complex cases, part of the skull may need to be replaced by a biomedical implant. Even when the skull is not damaged, such accidents can result in brain swelling treated by decompressive craniectomy. Usually, after recovery, the part of the skull that has been removed is replaced by a prosthesis. In such situations, a numerical tool able to analyse the choice of prosthesis material depending on the patient's specific activity has the potential to be extremely useful for clinicians. The work proposed here focuses on the development and use of a numerical model for the analysis of cranial implants under impact conditions. In particular, two main biomaterials commonly employed for this kind of prosthesis are polyether-ether-ketone (PEEK) and macroporous hydroxyapatite (HA). In order to study the suitability of these implants, a finite element head model comprising scalp, skull, cerebral falx, cerebrospinal fluid and brain tissues, with a cranial implant replacing part of the skull has been developed from magnetic resonance imaging data. The human tissues and these two biocompatible materials have been independently studied and constitutive models for both are provided here. A numerical model of the human head under impact loading is then implemented and validated, and a numerical comparison of the mechanical impact response of PEEK and HA implants is presented. This comparison was carried out in terms of the effectiveness of both implants in ensuring structural integrity and preventing traumatic brain injury. The results obtained in this work highlight the need to take into account environmental mechanical considerations to select the optimal implant depending on the specific patient: whereas HA implants present attractive biointegration properties, PEEK implant can potentially be a much more appropriate choice in a demanding mechanical life style. Finally, a novel methodology is proposed to assess the need for further clinical evaluation in case of impact for both implants over a large range of impact conditions.
spellingShingle Garcia-Gonzalez, D
Jayaratnam, J
Sotiropoulos, S
Yoon, S
Cook, J
Siviour, C
Arias, A
Jerusalem, A
On the mechanical behaviour of PEEK and HA cranial implants under impact loading
title On the mechanical behaviour of PEEK and HA cranial implants under impact loading
title_full On the mechanical behaviour of PEEK and HA cranial implants under impact loading
title_fullStr On the mechanical behaviour of PEEK and HA cranial implants under impact loading
title_full_unstemmed On the mechanical behaviour of PEEK and HA cranial implants under impact loading
title_short On the mechanical behaviour of PEEK and HA cranial implants under impact loading
title_sort on the mechanical behaviour of peek and ha cranial implants under impact loading
work_keys_str_mv AT garciagonzalezd onthemechanicalbehaviourofpeekandhacranialimplantsunderimpactloading
AT jayaratnamj onthemechanicalbehaviourofpeekandhacranialimplantsunderimpactloading
AT sotiropouloss onthemechanicalbehaviourofpeekandhacranialimplantsunderimpactloading
AT yoons onthemechanicalbehaviourofpeekandhacranialimplantsunderimpactloading
AT cookj onthemechanicalbehaviourofpeekandhacranialimplantsunderimpactloading
AT siviourc onthemechanicalbehaviourofpeekandhacranialimplantsunderimpactloading
AT ariasa onthemechanicalbehaviourofpeekandhacranialimplantsunderimpactloading
AT jerusalema onthemechanicalbehaviourofpeekandhacranialimplantsunderimpactloading