Electromagnetic background tests for the ILC interaction-point feedback system
We present results obtained with the T-488 experiment at SLAC Endstation A (ESA). A material model of the ILC extraction-fine design was assembled and installed in ESA. The module includes materials representing the mask, beamline calorimeter, and first extraction quadrupole, encompassing a striplin...
Main Authors: | , , , , , , , , , , , , , , |
---|---|
Format: | Conference item |
Published: |
2007
|
_version_ | 1826306687963758592 |
---|---|
author | Burrows, P Christian, G Clarke, C Constance, B Khah, H Hartin, T Perry, C Swinson, C Kalinin, A Arnold, R Molloy, S Smith, S White, G Woods, M IEEE |
author_facet | Burrows, P Christian, G Clarke, C Constance, B Khah, H Hartin, T Perry, C Swinson, C Kalinin, A Arnold, R Molloy, S Smith, S White, G Woods, M IEEE |
author_sort | Burrows, P |
collection | OXFORD |
description | We present results obtained with the T-488 experiment at SLAC Endstation A (ESA). A material model of the ILC extraction-fine design was assembled and installed in ESA. The module includes materials representing the mask, beamline calorimeter, and first extraction quadrupole, encompassing a stripline interaction-point feedback system beam position monitor (BPM). The SLAC high-energy electron beam was used to irradiate the module in order to mimic the electromagnetic (EM) backgrounds expected in the ILC interaction region. The impact upon the performance of the feedback BPM was measured, and compared with detailed simulations of its expected response. |
first_indexed | 2024-03-07T06:51:45Z |
format | Conference item |
id | oxford-uuid:fccb766c-c8d2-481b-8282-cc742cbc267d |
institution | University of Oxford |
last_indexed | 2024-03-07T06:51:45Z |
publishDate | 2007 |
record_format | dspace |
spelling | oxford-uuid:fccb766c-c8d2-481b-8282-cc742cbc267d2022-03-27T13:23:40ZElectromagnetic background tests for the ILC interaction-point feedback systemConference itemhttp://purl.org/coar/resource_type/c_5794uuid:fccb766c-c8d2-481b-8282-cc742cbc267dSymplectic Elements at Oxford2007Burrows, PChristian, GClarke, CConstance, BKhah, HHartin, TPerry, CSwinson, CKalinin, AArnold, RMolloy, SSmith, SWhite, GWoods, MIEEEWe present results obtained with the T-488 experiment at SLAC Endstation A (ESA). A material model of the ILC extraction-fine design was assembled and installed in ESA. The module includes materials representing the mask, beamline calorimeter, and first extraction quadrupole, encompassing a stripline interaction-point feedback system beam position monitor (BPM). The SLAC high-energy electron beam was used to irradiate the module in order to mimic the electromagnetic (EM) backgrounds expected in the ILC interaction region. The impact upon the performance of the feedback BPM was measured, and compared with detailed simulations of its expected response. |
spellingShingle | Burrows, P Christian, G Clarke, C Constance, B Khah, H Hartin, T Perry, C Swinson, C Kalinin, A Arnold, R Molloy, S Smith, S White, G Woods, M IEEE Electromagnetic background tests for the ILC interaction-point feedback system |
title | Electromagnetic background tests for the ILC interaction-point feedback system |
title_full | Electromagnetic background tests for the ILC interaction-point feedback system |
title_fullStr | Electromagnetic background tests for the ILC interaction-point feedback system |
title_full_unstemmed | Electromagnetic background tests for the ILC interaction-point feedback system |
title_short | Electromagnetic background tests for the ILC interaction-point feedback system |
title_sort | electromagnetic background tests for the ilc interaction point feedback system |
work_keys_str_mv | AT burrowsp electromagneticbackgroundtestsfortheilcinteractionpointfeedbacksystem AT christiang electromagneticbackgroundtestsfortheilcinteractionpointfeedbacksystem AT clarkec electromagneticbackgroundtestsfortheilcinteractionpointfeedbacksystem AT constanceb electromagneticbackgroundtestsfortheilcinteractionpointfeedbacksystem AT khahh electromagneticbackgroundtestsfortheilcinteractionpointfeedbacksystem AT hartint electromagneticbackgroundtestsfortheilcinteractionpointfeedbacksystem AT perryc electromagneticbackgroundtestsfortheilcinteractionpointfeedbacksystem AT swinsonc electromagneticbackgroundtestsfortheilcinteractionpointfeedbacksystem AT kalinina electromagneticbackgroundtestsfortheilcinteractionpointfeedbacksystem AT arnoldr electromagneticbackgroundtestsfortheilcinteractionpointfeedbacksystem AT molloys electromagneticbackgroundtestsfortheilcinteractionpointfeedbacksystem AT smiths electromagneticbackgroundtestsfortheilcinteractionpointfeedbacksystem AT whiteg electromagneticbackgroundtestsfortheilcinteractionpointfeedbacksystem AT woodsm electromagneticbackgroundtestsfortheilcinteractionpointfeedbacksystem AT ieee electromagneticbackgroundtestsfortheilcinteractionpointfeedbacksystem |