Determination of phenol in wastewater sample by using high performance liquid chromatography (HPLC) / Nurul Kudsiah Hj Katemon

The presence of phenol in water is risky to living organism as the toxicity effect causes the long-term exposure. In this research, the analysis was accomplished on a Cl8 column with UV-Vis detector (HPLC-UV) for determination of phenol in wastewater water while the solid phase extraction (SPE) is u...

Full description

Bibliographic Details
Main Author: Katemon, Nurul Kudsiah
Format: Student Project
Language:English
Published: Faculty of Applied Sciences 2017
Subjects:
Online Access:https://ir.uitm.edu.my/id/eprint/26877/1/PPb_NURUL%20KUDSIAH%20HJ%20KATEMON%20AS%20N%2017_5.pdf
_version_ 1825736536415535104
author Katemon, Nurul Kudsiah
author_facet Katemon, Nurul Kudsiah
author_sort Katemon, Nurul Kudsiah
collection UITM
description The presence of phenol in water is risky to living organism as the toxicity effect causes the long-term exposure. In this research, the analysis was accomplished on a Cl8 column with UV-Vis detector (HPLC-UV) for determination of phenol in wastewater water while the solid phase extraction (SPE) is used as sample preparation technique. Five mL of load sample was used as the optimized variable in SPE while 0.75 mL/min was used as flow-rate on eluent in HPLC. The analytical method was validated according to the following parameter, which are precision, linear range, limit of detection (LOD), and limit of quantitation (LOQ). A good linear correlation coefficient with R2 = 0.9991 was observed over the range of 3.05 to 30.0 μg/mL. The limit of detection was calculated to be 0.41 μg/mL, while the limit of quantitation value of the validated method was measured to be 1.37 μg/mL. Good recoveries were obtained in the range between 90 to 120%. In conclusion, the proposed method was found to be appropriate and accurate for the determination of phenol in wastewater by using HPLC.
first_indexed 2024-03-06T02:04:18Z
format Student Project
id uitm.eprints-6877
institution Universiti Teknologi MARA
language English
last_indexed 2024-03-06T02:04:18Z
publishDate 2017
publisher Faculty of Applied Sciences
record_format dspace
spelling uitm.eprints-68772019-12-16T07:31:02Z https://ir.uitm.edu.my/id/eprint/26877/ Determination of phenol in wastewater sample by using high performance liquid chromatography (HPLC) / Nurul Kudsiah Hj Katemon Katemon, Nurul Kudsiah QD Chemistry Extraction (Chemistry) The presence of phenol in water is risky to living organism as the toxicity effect causes the long-term exposure. In this research, the analysis was accomplished on a Cl8 column with UV-Vis detector (HPLC-UV) for determination of phenol in wastewater water while the solid phase extraction (SPE) is used as sample preparation technique. Five mL of load sample was used as the optimized variable in SPE while 0.75 mL/min was used as flow-rate on eluent in HPLC. The analytical method was validated according to the following parameter, which are precision, linear range, limit of detection (LOD), and limit of quantitation (LOQ). A good linear correlation coefficient with R2 = 0.9991 was observed over the range of 3.05 to 30.0 μg/mL. The limit of detection was calculated to be 0.41 μg/mL, while the limit of quantitation value of the validated method was measured to be 1.37 μg/mL. Good recoveries were obtained in the range between 90 to 120%. In conclusion, the proposed method was found to be appropriate and accurate for the determination of phenol in wastewater by using HPLC. Faculty of Applied Sciences 2017 Student Project NonPeerReviewed text en https://ir.uitm.edu.my/id/eprint/26877/1/PPb_NURUL%20KUDSIAH%20HJ%20KATEMON%20AS%20N%2017_5.pdf Determination of phenol in wastewater sample by using high performance liquid chromatography (HPLC) / Nurul Kudsiah Hj Katemon. (2017) [Student Project] <http://terminalib.uitm.edu.my/26877.pdf> (Unpublished)
spellingShingle QD Chemistry
Extraction (Chemistry)
Katemon, Nurul Kudsiah
Determination of phenol in wastewater sample by using high performance liquid chromatography (HPLC) / Nurul Kudsiah Hj Katemon
title Determination of phenol in wastewater sample by using high performance liquid chromatography (HPLC) / Nurul Kudsiah Hj Katemon
title_full Determination of phenol in wastewater sample by using high performance liquid chromatography (HPLC) / Nurul Kudsiah Hj Katemon
title_fullStr Determination of phenol in wastewater sample by using high performance liquid chromatography (HPLC) / Nurul Kudsiah Hj Katemon
title_full_unstemmed Determination of phenol in wastewater sample by using high performance liquid chromatography (HPLC) / Nurul Kudsiah Hj Katemon
title_short Determination of phenol in wastewater sample by using high performance liquid chromatography (HPLC) / Nurul Kudsiah Hj Katemon
title_sort determination of phenol in wastewater sample by using high performance liquid chromatography hplc nurul kudsiah hj katemon
topic QD Chemistry
Extraction (Chemistry)
url https://ir.uitm.edu.my/id/eprint/26877/1/PPb_NURUL%20KUDSIAH%20HJ%20KATEMON%20AS%20N%2017_5.pdf
work_keys_str_mv AT katemonnurulkudsiah determinationofphenolinwastewatersamplebyusinghighperformanceliquidchromatographyhplcnurulkudsiahhjkatemon