Detection of o-nitrophenol in water samples by using high performance liquid chromatography (hplc) / Iffah Syazana Rusli

Phenolic compound such as o-nitrophenol can be presented in the environment. Yet, in the water which will be consumed by the living organism. Due to its toxicity, it will give an effect towards the consumer. Thus, in this research, onitrophenol in water samples was detected by using HPLC-UV detector...

Full description

Bibliographic Details
Main Author: Rusli, Iffah Syazana
Format: Student Project
Language:English
Published: Faculty of Applied Sciences 2017
Subjects:
Online Access:https://ir.uitm.edu.my/id/eprint/27138/1/PPb_IFFAH%20SYAZANA%20RUSLI%20AS%20N%2017_5.pdf
_version_ 1825736590386790400
author Rusli, Iffah Syazana
author_facet Rusli, Iffah Syazana
author_sort Rusli, Iffah Syazana
collection UITM
description Phenolic compound such as o-nitrophenol can be presented in the environment. Yet, in the water which will be consumed by the living organism. Due to its toxicity, it will give an effect towards the consumer. Thus, in this research, onitrophenol in water samples was detected by using HPLC-UV detector. There were few parameters were optimized which are effect of flow rate, column temperature, composition of mobile phase and wavelength by using 30 ppm of standard stock solution of o-nitrophenol. This analysis used C1s column as its stationary phase with isocratic elution of methanol:l % acetic acid (70:30) as the mobile phase. From the results obtained, the optimum flow rate, column temperature, composition of mobile phase and wavelength were 0.75 mL/min, 26°C, methanol:l % acetic acid (70:30) and 274 nm respectively. Solid phase extraction (SPE) method was used as an extraction method of water samples. At the end of this analysis, the analytical method was validated according to various parameter such as calibration curve, limit of detection (LOD), limit of quantification (LOQ), relative standard deviation (RSD¾) and accuracy. For calibration curve ranging 5 ppm to 70 ppm, a good linear correlation coefficient was observed with R2 = 0.997. Next, for calculated LOD and LOQ were 0.031 ppm and 0.102 ppm respectively. Lastly, RSD¾ for sample A was 0.853% and sample B was 0%. Thus, it can be conclude that o-nitrophenol presence in the environment due to the decomposition of wood and leaves.
first_indexed 2024-03-06T02:05:04Z
format Student Project
id uitm.eprints-7138
institution Universiti Teknologi MARA
language English
last_indexed 2024-03-06T02:05:04Z
publishDate 2017
publisher Faculty of Applied Sciences
record_format dspace
spelling uitm.eprints-71382020-02-11T03:39:24Z https://ir.uitm.edu.my/id/eprint/27138/ Detection of o-nitrophenol in water samples by using high performance liquid chromatography (hplc) / Iffah Syazana Rusli Rusli, Iffah Syazana QD Chemistry Epoxy compounds Extraction (Chemistry) Phenolic compound such as o-nitrophenol can be presented in the environment. Yet, in the water which will be consumed by the living organism. Due to its toxicity, it will give an effect towards the consumer. Thus, in this research, onitrophenol in water samples was detected by using HPLC-UV detector. There were few parameters were optimized which are effect of flow rate, column temperature, composition of mobile phase and wavelength by using 30 ppm of standard stock solution of o-nitrophenol. This analysis used C1s column as its stationary phase with isocratic elution of methanol:l % acetic acid (70:30) as the mobile phase. From the results obtained, the optimum flow rate, column temperature, composition of mobile phase and wavelength were 0.75 mL/min, 26°C, methanol:l % acetic acid (70:30) and 274 nm respectively. Solid phase extraction (SPE) method was used as an extraction method of water samples. At the end of this analysis, the analytical method was validated according to various parameter such as calibration curve, limit of detection (LOD), limit of quantification (LOQ), relative standard deviation (RSD¾) and accuracy. For calibration curve ranging 5 ppm to 70 ppm, a good linear correlation coefficient was observed with R2 = 0.997. Next, for calculated LOD and LOQ were 0.031 ppm and 0.102 ppm respectively. Lastly, RSD¾ for sample A was 0.853% and sample B was 0%. Thus, it can be conclude that o-nitrophenol presence in the environment due to the decomposition of wood and leaves. Faculty of Applied Sciences 2017 Student Project NonPeerReviewed text en https://ir.uitm.edu.my/id/eprint/27138/1/PPb_IFFAH%20SYAZANA%20RUSLI%20AS%20N%2017_5.pdf Detection of o-nitrophenol in water samples by using high performance liquid chromatography (hplc) / Iffah Syazana Rusli. (2017) [Student Project] (Unpublished)
spellingShingle QD Chemistry
Epoxy compounds
Extraction (Chemistry)
Rusli, Iffah Syazana
Detection of o-nitrophenol in water samples by using high performance liquid chromatography (hplc) / Iffah Syazana Rusli
title Detection of o-nitrophenol in water samples by using high performance liquid chromatography (hplc) / Iffah Syazana Rusli
title_full Detection of o-nitrophenol in water samples by using high performance liquid chromatography (hplc) / Iffah Syazana Rusli
title_fullStr Detection of o-nitrophenol in water samples by using high performance liquid chromatography (hplc) / Iffah Syazana Rusli
title_full_unstemmed Detection of o-nitrophenol in water samples by using high performance liquid chromatography (hplc) / Iffah Syazana Rusli
title_short Detection of o-nitrophenol in water samples by using high performance liquid chromatography (hplc) / Iffah Syazana Rusli
title_sort detection of o nitrophenol in water samples by using high performance liquid chromatography hplc iffah syazana rusli
topic QD Chemistry
Epoxy compounds
Extraction (Chemistry)
url https://ir.uitm.edu.my/id/eprint/27138/1/PPb_IFFAH%20SYAZANA%20RUSLI%20AS%20N%2017_5.pdf
work_keys_str_mv AT rusliiffahsyazana detectionofonitrophenolinwatersamplesbyusinghighperformanceliquidchromatographyhplciffahsyazanarusli