Controlling the blood flow in the stenosed porous artery with magnetic field

The unsteady blood flow in the stenosed porous artery subjected to a magnetic field was studied analytically. Oscillating pressure gradient and periodic body acceleration were imposed on the flow field. The effects of the magnetic field and the permeability of the stenosed artery on the blood veloci...

Full description

Bibliographic Details
Main Authors: D.F. Jamil, R. Roslan, M. Abdulhameed, I. Hashim
Format: Article
Language:English
Published: Penerbit Universiti Kebangsaan Malaysia 2018
Online Access:http://journalarticle.ukm.my/12529/1/35%20D.F.%20Jamil.pdf
_version_ 1796931696604479488
author D.F. Jamil,
R. Roslan,
M. Abdulhameed,
I. Hashim,
author_facet D.F. Jamil,
R. Roslan,
M. Abdulhameed,
I. Hashim,
author_sort D.F. Jamil,
collection UKM
description The unsteady blood flow in the stenosed porous artery subjected to a magnetic field was studied analytically. Oscillating pressure gradient and periodic body acceleration were imposed on the flow field. The effects of the magnetic field and the permeability of the stenosed artery on the blood velocity were studied. The results showed that the magnetic field affected the flow field significantly which can be beneficial for some practical problems.
first_indexed 2024-03-06T04:21:51Z
format Article
id ukm.eprints-12529
institution Universiti Kebangsaan Malaysia
language English
last_indexed 2024-03-06T04:21:51Z
publishDate 2018
publisher Penerbit Universiti Kebangsaan Malaysia
record_format dspace
spelling ukm.eprints-125292019-01-28T21:47:55Z http://journalarticle.ukm.my/12529/ Controlling the blood flow in the stenosed porous artery with magnetic field D.F. Jamil, R. Roslan, M. Abdulhameed, I. Hashim, The unsteady blood flow in the stenosed porous artery subjected to a magnetic field was studied analytically. Oscillating pressure gradient and periodic body acceleration were imposed on the flow field. The effects of the magnetic field and the permeability of the stenosed artery on the blood velocity were studied. The results showed that the magnetic field affected the flow field significantly which can be beneficial for some practical problems. Penerbit Universiti Kebangsaan Malaysia 2018-10 Article PeerReviewed application/pdf en http://journalarticle.ukm.my/12529/1/35%20D.F.%20Jamil.pdf D.F. Jamil, and R. Roslan, and M. Abdulhameed, and I. Hashim, (2018) Controlling the blood flow in the stenosed porous artery with magnetic field. Sains Malaysiana, 47 (10). pp. 2581-2587. ISSN 0126-6039 http://www.ukm.my/jsm/malay_journals/jilid47bil10_2018/KandunganJilid47Bil10_2018.htm
spellingShingle D.F. Jamil,
R. Roslan,
M. Abdulhameed,
I. Hashim,
Controlling the blood flow in the stenosed porous artery with magnetic field
title Controlling the blood flow in the stenosed porous artery with magnetic field
title_full Controlling the blood flow in the stenosed porous artery with magnetic field
title_fullStr Controlling the blood flow in the stenosed porous artery with magnetic field
title_full_unstemmed Controlling the blood flow in the stenosed porous artery with magnetic field
title_short Controlling the blood flow in the stenosed porous artery with magnetic field
title_sort controlling the blood flow in the stenosed porous artery with magnetic field
url http://journalarticle.ukm.my/12529/1/35%20D.F.%20Jamil.pdf
work_keys_str_mv AT dfjamil controllingthebloodflowinthestenosedporousarterywithmagneticfield
AT rroslan controllingthebloodflowinthestenosedporousarterywithmagneticfield
AT mabdulhameed controllingthebloodflowinthestenosedporousarterywithmagneticfield
AT ihashim controllingthebloodflowinthestenosedporousarterywithmagneticfield