Parametric studies of direct methanol fuel cell under different modes of operation

Direct methanol fuel cell (DMFC) performance tests were carried out in different modes of operation, namely, passive, active (air as oxidant) and active (oxygen as oxidant). Few parameters including methanol concentration (2 M, 4 M, 6 M, and 8 M) and methanol flow rate (1-4 mL min-1) were consider...

Full description

Bibliographic Details
Main Authors: Farah Atiqah Abdullah, Siti Kartom Kamarudin, Azran Mohd Zainoodin, Mohd Shahbudin Masdar
Format: Article
Language:English
Published: Penerbit Universiti Kebangsaan Malaysia 2020
Online Access:http://journalarticle.ukm.my/14854/1/19.pdf
_version_ 1796932151215652864
author Farah Atiqah Abdullah,
Siti Kartom Kamarudin,
Azran Mohd Zainoodin,
Mohd Shahbudin Masdar,
author_facet Farah Atiqah Abdullah,
Siti Kartom Kamarudin,
Azran Mohd Zainoodin,
Mohd Shahbudin Masdar,
author_sort Farah Atiqah Abdullah,
collection UKM
description Direct methanol fuel cell (DMFC) performance tests were carried out in different modes of operation, namely, passive, active (air as oxidant) and active (oxygen as oxidant). Few parameters including methanol concentration (2 M, 4 M, 6 M, and 8 M) and methanol flow rate (1-4 mL min-1) were considered to investigate their effects on the DMFC performance. Fuel consumption was indicated by refractive index tests. Results showed that the performance of DMFC increased with the increase of methanol concentration and flow rate, until they reach certain values, i.e., 4-6 M and 2 mL min-1. Furthermore, for all parameters, the active mode with oxygen yielded the highest power density, followed by the active mode with air and passive DMFC system. The active mode with oxygen yielded the power density which peaks at 10.41 mW cm-2 during 6 M of methanol concentration and 2 mL min-1 rate of flowing methanol, followed by active mode with air at the cathode with 8.39 mW cm-2 and passive mode with 5.39 mW cm-2 respectively. It also records a better fuel consumption efficiency among all modes. These results indicate that investigating the level of fuel concentration and flow rate can lead to enhancement of mass transport and diffusion thus generating better performance of DMFC system.
first_indexed 2024-03-06T04:28:35Z
format Article
id ukm.eprints-14854
institution Universiti Kebangsaan Malaysia
language English
last_indexed 2024-03-06T04:28:35Z
publishDate 2020
publisher Penerbit Universiti Kebangsaan Malaysia
record_format dspace
spelling ukm.eprints-148542020-07-10T08:51:13Z http://journalarticle.ukm.my/14854/ Parametric studies of direct methanol fuel cell under different modes of operation Farah Atiqah Abdullah, Siti Kartom Kamarudin, Azran Mohd Zainoodin, Mohd Shahbudin Masdar, Direct methanol fuel cell (DMFC) performance tests were carried out in different modes of operation, namely, passive, active (air as oxidant) and active (oxygen as oxidant). Few parameters including methanol concentration (2 M, 4 M, 6 M, and 8 M) and methanol flow rate (1-4 mL min-1) were considered to investigate their effects on the DMFC performance. Fuel consumption was indicated by refractive index tests. Results showed that the performance of DMFC increased with the increase of methanol concentration and flow rate, until they reach certain values, i.e., 4-6 M and 2 mL min-1. Furthermore, for all parameters, the active mode with oxygen yielded the highest power density, followed by the active mode with air and passive DMFC system. The active mode with oxygen yielded the power density which peaks at 10.41 mW cm-2 during 6 M of methanol concentration and 2 mL min-1 rate of flowing methanol, followed by active mode with air at the cathode with 8.39 mW cm-2 and passive mode with 5.39 mW cm-2 respectively. It also records a better fuel consumption efficiency among all modes. These results indicate that investigating the level of fuel concentration and flow rate can lead to enhancement of mass transport and diffusion thus generating better performance of DMFC system. Penerbit Universiti Kebangsaan Malaysia 2020-02 Article PeerReviewed application/pdf en http://journalarticle.ukm.my/14854/1/19.pdf Farah Atiqah Abdullah, and Siti Kartom Kamarudin, and Azran Mohd Zainoodin, and Mohd Shahbudin Masdar, (2020) Parametric studies of direct methanol fuel cell under different modes of operation. Jurnal Kejuruteraan, 32 (1). pp. 159-164. ISSN 0128-0198 http://www.ukm.my/jkukm/volume-321-2020/
spellingShingle Farah Atiqah Abdullah,
Siti Kartom Kamarudin,
Azran Mohd Zainoodin,
Mohd Shahbudin Masdar,
Parametric studies of direct methanol fuel cell under different modes of operation
title Parametric studies of direct methanol fuel cell under different modes of operation
title_full Parametric studies of direct methanol fuel cell under different modes of operation
title_fullStr Parametric studies of direct methanol fuel cell under different modes of operation
title_full_unstemmed Parametric studies of direct methanol fuel cell under different modes of operation
title_short Parametric studies of direct methanol fuel cell under different modes of operation
title_sort parametric studies of direct methanol fuel cell under different modes of operation
url http://journalarticle.ukm.my/14854/1/19.pdf
work_keys_str_mv AT farahatiqahabdullah parametricstudiesofdirectmethanolfuelcellunderdifferentmodesofoperation
AT sitikartomkamarudin parametricstudiesofdirectmethanolfuelcellunderdifferentmodesofoperation
AT azranmohdzainoodin parametricstudiesofdirectmethanolfuelcellunderdifferentmodesofoperation
AT mohdshahbudinmasdar parametricstudiesofdirectmethanolfuelcellunderdifferentmodesofoperation