Calculating in-vivo short-term precision error of dual-energy x-ray absorptiometry in human and animal: a technical report

Bone mineral density (BMD) measurement by dual-energy X-ray absorptiometry (DXA) is important in diagnosing osteoporosis. Precision error of DXA is a useful measure to determine a true change in BMD value. This study aimed to investigate the short-term coefficient of variance of Hologic Discovery QD...

Full description

Bibliographic Details
Main Authors: Subramaniam S, Mohamad NV, Chan, CY, Ima Nirwana Soelaiman, Chin, Kok Yong
Format: Article
Language:English
Published: Pusat Perubatan Universiti Kebangsaan Malaysia 2020
Online Access:http://journalarticle.ukm.my/15108/1/6_ms0316_pdf_60643.pdf
_version_ 1796932190924177408
author Subramaniam S,
Mohamad NV,
Chan, CY
Ima Nirwana Soelaiman,
Chin, Kok Yong
author_facet Subramaniam S,
Mohamad NV,
Chan, CY
Ima Nirwana Soelaiman,
Chin, Kok Yong
author_sort Subramaniam S,
collection UKM
description Bone mineral density (BMD) measurement by dual-energy X-ray absorptiometry (DXA) is important in diagnosing osteoporosis. Precision error of DXA is a useful measure to determine a true change in BMD value. This study aimed to investigate the short-term coefficient of variance of Hologic Discovery QDR Wi DXA machine. The lumbar spine and hip BMD of fifteen healthy volunteers (mean age: 30.67 + 10.41 years) and the whole body BMD of fifteen female Sprague-Dawley rats (aged three months old) were scanned using Hologic Discovery QDR Wi DXA machine. Each volunteer and rat underwent triplicate scans to assess the reproducibility of BMD values. The interval between the scans ranged within 1 to 12 weeks for human subjects. For animal samples, the scans were repeated on the same day after repositioning. The precision error was expressed as a percentage coefficient of variance (%CV). The %CV obtained for lumbar spine and hip BMD for human were 1.8% and 1.2%, respectively. The %CV for whole body BMD of rats was 1.4%. The short-term CV demonstrated for both human and animal in the present study were comparable. The precision error of DXA must be monitored to ensure optimal performance of the device.
first_indexed 2024-03-06T04:29:11Z
format Article
id ukm.eprints-15108
institution Universiti Kebangsaan Malaysia
language English
last_indexed 2024-03-06T04:29:11Z
publishDate 2020
publisher Pusat Perubatan Universiti Kebangsaan Malaysia
record_format dspace
spelling ukm.eprints-151082020-08-26T01:14:12Z http://journalarticle.ukm.my/15108/ Calculating in-vivo short-term precision error of dual-energy x-ray absorptiometry in human and animal: a technical report Subramaniam S, Mohamad NV, Chan, CY Ima Nirwana Soelaiman, Chin, Kok Yong Bone mineral density (BMD) measurement by dual-energy X-ray absorptiometry (DXA) is important in diagnosing osteoporosis. Precision error of DXA is a useful measure to determine a true change in BMD value. This study aimed to investigate the short-term coefficient of variance of Hologic Discovery QDR Wi DXA machine. The lumbar spine and hip BMD of fifteen healthy volunteers (mean age: 30.67 + 10.41 years) and the whole body BMD of fifteen female Sprague-Dawley rats (aged three months old) were scanned using Hologic Discovery QDR Wi DXA machine. Each volunteer and rat underwent triplicate scans to assess the reproducibility of BMD values. The interval between the scans ranged within 1 to 12 weeks for human subjects. For animal samples, the scans were repeated on the same day after repositioning. The precision error was expressed as a percentage coefficient of variance (%CV). The %CV obtained for lumbar spine and hip BMD for human were 1.8% and 1.2%, respectively. The %CV for whole body BMD of rats was 1.4%. The short-term CV demonstrated for both human and animal in the present study were comparable. The precision error of DXA must be monitored to ensure optimal performance of the device. Pusat Perubatan Universiti Kebangsaan Malaysia 2020 Article PeerReviewed application/pdf en http://journalarticle.ukm.my/15108/1/6_ms0316_pdf_60643.pdf Subramaniam S, and Mohamad NV, and Chan, CY and Ima Nirwana Soelaiman, and Chin, Kok Yong (2020) Calculating in-vivo short-term precision error of dual-energy x-ray absorptiometry in human and animal: a technical report. Medicine & Health, 15 (1). pp. 70-77. ISSN 2289-5728 http://www.medicineandhealthukm.com/toc/15/1
spellingShingle Subramaniam S,
Mohamad NV,
Chan, CY
Ima Nirwana Soelaiman,
Chin, Kok Yong
Calculating in-vivo short-term precision error of dual-energy x-ray absorptiometry in human and animal: a technical report
title Calculating in-vivo short-term precision error of dual-energy x-ray absorptiometry in human and animal: a technical report
title_full Calculating in-vivo short-term precision error of dual-energy x-ray absorptiometry in human and animal: a technical report
title_fullStr Calculating in-vivo short-term precision error of dual-energy x-ray absorptiometry in human and animal: a technical report
title_full_unstemmed Calculating in-vivo short-term precision error of dual-energy x-ray absorptiometry in human and animal: a technical report
title_short Calculating in-vivo short-term precision error of dual-energy x-ray absorptiometry in human and animal: a technical report
title_sort calculating in vivo short term precision error of dual energy x ray absorptiometry in human and animal a technical report
url http://journalarticle.ukm.my/15108/1/6_ms0316_pdf_60643.pdf
work_keys_str_mv AT subramaniams calculatinginvivoshorttermprecisionerrorofdualenergyxrayabsorptiometryinhumanandanimalatechnicalreport
AT mohamadnv calculatinginvivoshorttermprecisionerrorofdualenergyxrayabsorptiometryinhumanandanimalatechnicalreport
AT chancy calculatinginvivoshorttermprecisionerrorofdualenergyxrayabsorptiometryinhumanandanimalatechnicalreport
AT imanirwanasoelaiman calculatinginvivoshorttermprecisionerrorofdualenergyxrayabsorptiometryinhumanandanimalatechnicalreport
AT chinkokyong calculatinginvivoshorttermprecisionerrorofdualenergyxrayabsorptiometryinhumanandanimalatechnicalreport