Monte Carlo investigation on neutron dosimetry parameters of 252Cf Isotron brachytherapy source
In the present study, all dosimetry parameters around the 252Cf Isotron source for neutron brachytherapy were calculated. The 252Cf neutron energy spectrum was modeled using the Maxwellian spectrum. The calculations were performed using MCNPX.2.6.0 code based on the TG-43U1 protocol in the water med...
Main Authors: | Ahmadi, Ome Leila, Anbaran, Hossein Tavakoli |
---|---|
Format: | Article |
Language: | English |
Published: |
Penerbit Universiti Kebangsaan Malaysia
2020
|
Online Access: | http://journalarticle.ukm.my/15200/1/ARTIKEL%2024.pdf |
Similar Items
-
Calculation of Dose Distribution in Neutron Brachytherapy Using 252-Cf Source Through the Monte Carlo Simulation and Comparison with Experimental Data
by: Gh Izadi Vasafi, et al.
Published: (2018-05-01) -
The development and evaluation of 252Cf neutron irradiation facilities for two biomedical applications using discrete ordinates, Monte Carlo, and experimental methods.
by: Pettigrew, Roderic Ivan.
Published: (2021) -
Barite concrete-based cement composites for 252Cf spontaneous neutron and 60Co/192Ir shielding based on Monte Carlo computation
by: Cebastien Joel Guembou Shouop, et al.
Published: (2022-01-01) -
Brachytherapy Dosimetry Parameter Measurement for Cobalt-60 Source using Monte Carlo Simulations Geant4, and Comparing the Results with Standard BEBIG Source
by: Alireza Khazani, et al.
Published: (2020-03-01) -
High dose rate 192Ir brachytherapy source model Monte Carlo dosimetry: mHDR-v2 and mHDR-v2r.
by: Shuhei Tsuji, et al.
Published: (2024-01-01)