Blood cell tracing in a microchannel by using dielectrophoresis force

The conventional techniques of platelet separation are by using a centrifugation and acoustic. However, by using these techniques, the platelets become active due to the relatively high-speed centrifugal force and large amount of a sample usage. Therefore, to overcome this problem, an electric separ...

Full description

Bibliographic Details
Main Authors: Nur Tantiyani Ali Othman, Farah Syafiqah Abul Kalam
Format: Article
Language:English
Published: Penerbit Universiti Kebangsaan Malaysia 2021
Online Access:http://journalarticle.ukm.my/16474/1/06.pdf
_version_ 1796932472419647488
author Nur Tantiyani Ali Othman,
Farah Syafiqah Abul Kalam,
author_facet Nur Tantiyani Ali Othman,
Farah Syafiqah Abul Kalam,
author_sort Nur Tantiyani Ali Othman,
collection UKM
description The conventional techniques of platelet separation are by using a centrifugation and acoustic. However, by using these techniques, the platelets become active due to the relatively high-speed centrifugal force and large amount of a sample usage. Therefore, to overcome this problem, an electric separation technique is preferred as it relies more on the dielectric properties of particles, that allow for highly selective and sensitive analysis. One of them is dielectrophoresis (DEP), which is the force resulting from an interaction between bipolar particles in a non-uniform electric field that can be used to separate neutral particles. The DEP force allows the separation of platelets from red blood cells due to dielectric properties of the particles and medium as it requires small quantities of samples, lower reagents usage, and low-cost equipment. In this study, H-type microchannel with two inlets and outlets was developed by using COMSOL© software to observe the cell distribution at blood concentrations; CA=0.01, 0.015, 0.02, 0.025 and 0.03 mol/m3, with feed velocities at the inlet B; vB=600, 700, 800, 900 and 1000 μm/s and at voltages charged; V=-30V to 30V that applied at the five electrodes. The simulation results show the optimization of blood cell concentration and velocity were achieved at the outlets at CA=0.01 mol/m3 and vB=800 μm/s, respectively. Moreover, the optimum voltage for platelet cell separation was at V=10V as it shows the highest DEP force; FDEP=-3.19×1013 N/m as compared to the other tested voltages.
first_indexed 2024-03-06T04:32:58Z
format Article
id ukm.eprints-16474
institution Universiti Kebangsaan Malaysia
language English
last_indexed 2024-03-06T04:32:58Z
publishDate 2021
publisher Penerbit Universiti Kebangsaan Malaysia
record_format dspace
spelling ukm.eprints-164742021-04-26T06:47:05Z http://journalarticle.ukm.my/16474/ Blood cell tracing in a microchannel by using dielectrophoresis force Nur Tantiyani Ali Othman, Farah Syafiqah Abul Kalam, The conventional techniques of platelet separation are by using a centrifugation and acoustic. However, by using these techniques, the platelets become active due to the relatively high-speed centrifugal force and large amount of a sample usage. Therefore, to overcome this problem, an electric separation technique is preferred as it relies more on the dielectric properties of particles, that allow for highly selective and sensitive analysis. One of them is dielectrophoresis (DEP), which is the force resulting from an interaction between bipolar particles in a non-uniform electric field that can be used to separate neutral particles. The DEP force allows the separation of platelets from red blood cells due to dielectric properties of the particles and medium as it requires small quantities of samples, lower reagents usage, and low-cost equipment. In this study, H-type microchannel with two inlets and outlets was developed by using COMSOL© software to observe the cell distribution at blood concentrations; CA=0.01, 0.015, 0.02, 0.025 and 0.03 mol/m3, with feed velocities at the inlet B; vB=600, 700, 800, 900 and 1000 μm/s and at voltages charged; V=-30V to 30V that applied at the five electrodes. The simulation results show the optimization of blood cell concentration and velocity were achieved at the outlets at CA=0.01 mol/m3 and vB=800 μm/s, respectively. Moreover, the optimum voltage for platelet cell separation was at V=10V as it shows the highest DEP force; FDEP=-3.19×1013 N/m as compared to the other tested voltages. Penerbit Universiti Kebangsaan Malaysia 2021 Article PeerReviewed application/pdf en http://journalarticle.ukm.my/16474/1/06.pdf Nur Tantiyani Ali Othman, and Farah Syafiqah Abul Kalam, (2021) Blood cell tracing in a microchannel by using dielectrophoresis force. Jurnal Kejuruteraan, 33 (1). pp. 55-61. ISSN 0128-0198 https://www.ukm.my/jkukm/volume-331-2021/
spellingShingle Nur Tantiyani Ali Othman,
Farah Syafiqah Abul Kalam,
Blood cell tracing in a microchannel by using dielectrophoresis force
title Blood cell tracing in a microchannel by using dielectrophoresis force
title_full Blood cell tracing in a microchannel by using dielectrophoresis force
title_fullStr Blood cell tracing in a microchannel by using dielectrophoresis force
title_full_unstemmed Blood cell tracing in a microchannel by using dielectrophoresis force
title_short Blood cell tracing in a microchannel by using dielectrophoresis force
title_sort blood cell tracing in a microchannel by using dielectrophoresis force
url http://journalarticle.ukm.my/16474/1/06.pdf
work_keys_str_mv AT nurtantiyanialiothman bloodcelltracinginamicrochannelbyusingdielectrophoresisforce
AT farahsyafiqahabulkalam bloodcelltracinginamicrochannelbyusingdielectrophoresisforce