Estimation of endotracheal tube cuff pressure among anaesthesia providers does experience matter?

The endotracheal tube (ETT) cuff pressure is usually estimated and assumed to be within the appropriate range. However, the estimation of cuff pressure may be influenced by the various estimation techniques used by anaesthesia providers and their different experience level. The main aim of this stud...

Full description

Bibliographic Details
Main Authors: Raha AR, Haslinda S, Nadia MN, Nurlia Y
Format: Article
Language:English
Published: Department of Surgery, UKM Medical Centre 2011
Online Access:http://journalarticle.ukm.my/2982/1/53-56.pdf
_version_ 1796927717013192704
author Raha AR,
Haslinda S,
Nadia MN,
Nurlia Y,
author_facet Raha AR,
Haslinda S,
Nadia MN,
Nurlia Y,
author_sort Raha AR,
collection UKM
description The endotracheal tube (ETT) cuff pressure is usually estimated and assumed to be within the appropriate range. However, the estimation of cuff pressure may be influenced by the various estimation techniques used by anaesthesia providers and their different experience level. The main aim of this study was to observe the correlation between the experience of the anaesthesia providers and their ability to estimate endotracheal cuff pressure in a correct manner. One hundred anaesthesia providers were classified into three different groups based on their months of anaesthetic experience: Group I (< 36 months), Group II (36 to 59 months) and Group III (≥ 60 months). Following intubation, the ETT cuff was inflated by the anaesthetic nurse and ETT placement verified by the anaesthesia provider. Using the pilot balloon palpation technique (PBPT), the cuff pressure was estimated to be within the appropriate pressure range, over or under-inflated. The necessary adjustments were made if needed after measurement with a VBM™ Manometer Pressure Gauge. More number of months of anaesthesia experience was not associated with a greater ability to correctly estimate the ETT cuff pressure. However, this correlation was poor (r = - 0.177). The pilot balloon palpation technique was found to be only moderately sensitive (76.5%) but poorly specific (42.9%) for correct estimation of the ETT cuff pressure, whereby PPV and NPV were 58.2% and 63.6%, respectively. The technique was 50% (95% CI 24.04 - 75.95) sensitive while correctly estimating the under-inflated cuff and 60% (95%CI 13.25-37.81) sensitive to correctly estimating the over-inflated cuff. The results depict that the experience of anaesthesia providers did not correlate with the ability to correctly estimate the ETT cuff pressure
first_indexed 2024-03-06T03:48:19Z
format Article
id ukm.eprints-2982
institution Universiti Kebangsaan Malaysia
language English
last_indexed 2024-03-06T03:48:19Z
publishDate 2011
publisher Department of Surgery, UKM Medical Centre
record_format dspace
spelling ukm.eprints-29822016-12-14T06:33:14Z http://journalarticle.ukm.my/2982/ Estimation of endotracheal tube cuff pressure among anaesthesia providers does experience matter? Raha AR, Haslinda S, Nadia MN, Nurlia Y, The endotracheal tube (ETT) cuff pressure is usually estimated and assumed to be within the appropriate range. However, the estimation of cuff pressure may be influenced by the various estimation techniques used by anaesthesia providers and their different experience level. The main aim of this study was to observe the correlation between the experience of the anaesthesia providers and their ability to estimate endotracheal cuff pressure in a correct manner. One hundred anaesthesia providers were classified into three different groups based on their months of anaesthetic experience: Group I (< 36 months), Group II (36 to 59 months) and Group III (≥ 60 months). Following intubation, the ETT cuff was inflated by the anaesthetic nurse and ETT placement verified by the anaesthesia provider. Using the pilot balloon palpation technique (PBPT), the cuff pressure was estimated to be within the appropriate pressure range, over or under-inflated. The necessary adjustments were made if needed after measurement with a VBM™ Manometer Pressure Gauge. More number of months of anaesthesia experience was not associated with a greater ability to correctly estimate the ETT cuff pressure. However, this correlation was poor (r = - 0.177). The pilot balloon palpation technique was found to be only moderately sensitive (76.5%) but poorly specific (42.9%) for correct estimation of the ETT cuff pressure, whereby PPV and NPV were 58.2% and 63.6%, respectively. The technique was 50% (95% CI 24.04 - 75.95) sensitive while correctly estimating the under-inflated cuff and 60% (95%CI 13.25-37.81) sensitive to correctly estimating the over-inflated cuff. The results depict that the experience of anaesthesia providers did not correlate with the ability to correctly estimate the ETT cuff pressure Department of Surgery, UKM Medical Centre 2011-10 Article PeerReviewed application/pdf en http://journalarticle.ukm.my/2982/1/53-56.pdf Raha AR, and Haslinda S, and Nadia MN, and Nurlia Y, (2011) Estimation of endotracheal tube cuff pressure among anaesthesia providers does experience matter? Journal of Surgical Academia, 1 (2). pp. 53-56. ISSN 2231-7481 http://jsurgacad.com/
spellingShingle Raha AR,
Haslinda S,
Nadia MN,
Nurlia Y,
Estimation of endotracheal tube cuff pressure among anaesthesia providers does experience matter?
title Estimation of endotracheal tube cuff pressure among anaesthesia providers does experience matter?
title_full Estimation of endotracheal tube cuff pressure among anaesthesia providers does experience matter?
title_fullStr Estimation of endotracheal tube cuff pressure among anaesthesia providers does experience matter?
title_full_unstemmed Estimation of endotracheal tube cuff pressure among anaesthesia providers does experience matter?
title_short Estimation of endotracheal tube cuff pressure among anaesthesia providers does experience matter?
title_sort estimation of endotracheal tube cuff pressure among anaesthesia providers does experience matter
url http://journalarticle.ukm.my/2982/1/53-56.pdf
work_keys_str_mv AT rahaar estimationofendotrachealtubecuffpressureamonganaesthesiaprovidersdoesexperiencematter
AT haslindas estimationofendotrachealtubecuffpressureamonganaesthesiaprovidersdoesexperiencematter
AT nadiamn estimationofendotrachealtubecuffpressureamonganaesthesiaprovidersdoesexperiencematter
AT nurliay estimationofendotrachealtubecuffpressureamonganaesthesiaprovidersdoesexperiencematter