Survei pengimejan elektrik dan georadar dalam kajian tanah runtuh Taman Hill View,Ampang Selangor

Electrical resistivity and Ground Penetrating Radar (GPR) surveys were carried out at Taman Hill View, Ampang, Selangor landslide area. This landslide site was a part of three similar landslides which occurred at Bukit Antarabangsa, Hulu Klang, Selangor. The landslide had occurred along the road to...

Full description

Bibliographic Details
Main Authors: Umar Hamzah, Nurul Fairuz Diyana Bahrudin, Mohd Azmi Ismail, Amry Amin Abbas
Format: Article
Published: Universiti Kebangsaan Malaysia 2009
_version_ 1796914147399565312
author Umar Hamzah,
Nurul Fairuz Diyana Bahrudin,
Mohd Azmi Ismail,
Amry Amin Abbas,
author_facet Umar Hamzah,
Nurul Fairuz Diyana Bahrudin,
Mohd Azmi Ismail,
Amry Amin Abbas,
author_sort Umar Hamzah,
collection UKM
description Electrical resistivity and Ground Penetrating Radar (GPR) surveys were carried out at Taman Hill View, Ampang, Selangor landslide area. This landslide site was a part of three similar landslides which occurred at Bukit Antarabangsa, Hulu Klang, Selangor. The landslide had occurred along the road to Bukit Antarabangsa and Athenaeum Tower. The objectives of these studies were to characterise the sliding material and to determine the depth of bedrock below the sliding surface using the electrical resistivity imaging technique as well as to recognise the fractured or weak zone using the GPR technique. The spacing between electrodes used in the survey was 2 to 2.5 m and the survey lines were chosen close to the borehole locations. With a total of 41 electrodes and spacing between each electrode of 2 to 2.5 m, the maximum current electrode spacing in this survey would be between 80-100 m resulting in the deepest subsurface depth investigated approximately at 20 to 25 m. A 100 MHz electromagnetic wave was used in the Ground Penetration Radar survey. The resistivity imaging result showed the weathered granite profile with resistivity value ranging from 2 to 7000 Ωm. The patterns also show that this area had a lot of fractured or weak zones up to a depth of 4 to 5 m based on the occurrence of low resistivities zones in between the high resistivities. These highly fractured and faulted zones also appeared in the GPR sections as shown by the presence of shifted reflectors and layer discontinuity.
first_indexed 2024-03-06T03:38:16Z
format Article
id ukm.eprints-30
institution Universiti Kebangsaan Malaysia
last_indexed 2024-03-06T03:38:16Z
publishDate 2009
publisher Universiti Kebangsaan Malaysia
record_format dspace
spelling ukm.eprints-302011-11-25T07:13:16Z http://journalarticle.ukm.my/30/ Survei pengimejan elektrik dan georadar dalam kajian tanah runtuh Taman Hill View,Ampang Selangor Umar Hamzah, Nurul Fairuz Diyana Bahrudin, Mohd Azmi Ismail, Amry Amin Abbas, Electrical resistivity and Ground Penetrating Radar (GPR) surveys were carried out at Taman Hill View, Ampang, Selangor landslide area. This landslide site was a part of three similar landslides which occurred at Bukit Antarabangsa, Hulu Klang, Selangor. The landslide had occurred along the road to Bukit Antarabangsa and Athenaeum Tower. The objectives of these studies were to characterise the sliding material and to determine the depth of bedrock below the sliding surface using the electrical resistivity imaging technique as well as to recognise the fractured or weak zone using the GPR technique. The spacing between electrodes used in the survey was 2 to 2.5 m and the survey lines were chosen close to the borehole locations. With a total of 41 electrodes and spacing between each electrode of 2 to 2.5 m, the maximum current electrode spacing in this survey would be between 80-100 m resulting in the deepest subsurface depth investigated approximately at 20 to 25 m. A 100 MHz electromagnetic wave was used in the Ground Penetration Radar survey. The resistivity imaging result showed the weathered granite profile with resistivity value ranging from 2 to 7000 Ωm. The patterns also show that this area had a lot of fractured or weak zones up to a depth of 4 to 5 m based on the occurrence of low resistivities zones in between the high resistivities. These highly fractured and faulted zones also appeared in the GPR sections as shown by the presence of shifted reflectors and layer discontinuity. Universiti Kebangsaan Malaysia 2009-10 Article PeerReviewed Umar Hamzah, and Nurul Fairuz Diyana Bahrudin, and Mohd Azmi Ismail, and Amry Amin Abbas, (2009) Survei pengimejan elektrik dan georadar dalam kajian tanah runtuh Taman Hill View,Ampang Selangor. Sains Malaysiana, 38 (5). pp. 645-653. ISSN 0126-6039 http://www.ukm.my/~jsm/contents.html
spellingShingle Umar Hamzah,
Nurul Fairuz Diyana Bahrudin,
Mohd Azmi Ismail,
Amry Amin Abbas,
Survei pengimejan elektrik dan georadar dalam kajian tanah runtuh Taman Hill View,Ampang Selangor
title Survei pengimejan elektrik dan georadar dalam kajian tanah runtuh Taman Hill View,Ampang Selangor
title_full Survei pengimejan elektrik dan georadar dalam kajian tanah runtuh Taman Hill View,Ampang Selangor
title_fullStr Survei pengimejan elektrik dan georadar dalam kajian tanah runtuh Taman Hill View,Ampang Selangor
title_full_unstemmed Survei pengimejan elektrik dan georadar dalam kajian tanah runtuh Taman Hill View,Ampang Selangor
title_short Survei pengimejan elektrik dan georadar dalam kajian tanah runtuh Taman Hill View,Ampang Selangor
title_sort survei pengimejan elektrik dan georadar dalam kajian tanah runtuh taman hill view ampang selangor
work_keys_str_mv AT umarhamzah surveipengimejanelektrikdangeoradardalamkajiantanahruntuhtamanhillviewampangselangor
AT nurulfairuzdiyanabahrudin surveipengimejanelektrikdangeoradardalamkajiantanahruntuhtamanhillviewampangselangor
AT mohdazmiismail surveipengimejanelektrikdangeoradardalamkajiantanahruntuhtamanhillviewampangselangor
AT amryaminabbas surveipengimejanelektrikdangeoradardalamkajiantanahruntuhtamanhillviewampangselangor