Appropriate geometrical ratio modeling of atrium for energy efficiency in office buildings

Atrium refers to an open interior space that can be potentially related to an exterior environment. Indeed, atrium is considered as a filter and obstacle blocking undesirable exterior environmental phenomena such as rain, snow and wind. A well designed atrium can contribute to have a significant...

Full description

Bibliographic Details
Main Authors: Nasrollahi, N., Abdolahzadeh, S., Litkohi, S.
Format: Article
Language:English
Published: Penerbit UKM 2015
Online Access:http://journalarticle.ukm.my/9126/1/165-521-1-PB.pdf
_version_ 1796930920381415424
author Nasrollahi, N.
Abdolahzadeh, S.
Litkohi, S.
author_facet Nasrollahi, N.
Abdolahzadeh, S.
Litkohi, S.
author_sort Nasrollahi, N.
collection UKM
description Atrium refers to an open interior space that can be potentially related to an exterior environment. Indeed, atrium is considered as a filter and obstacle blocking undesirable exterior environmental phenomena such as rain, snow and wind. A well designed atrium can contribute to have a significant effect on both; the building's energy performance and indoor environmental conditions. In this paper, the aim is to study the effect of atrium ratio on energy efficiency and comfort of the occupants in an office building in the city of Tehran. In this work, the length to width ratio of the office buildings is identified and the average height of these buildings and validated appropriateness are examined by field studies. The simulation modellings of Design Builder Software is used to model various aspects of the building such as building materials, architecture construction, heating, cooling and lighting systems. One way ANOVA and Duncan’s multiple range tests are used to determine the differences of daylight and compare their averages in different models. It is shown that by decreasing the ratio of atrium to total building area from 1:2 to 1:10, the annual energy consumption reduces i.e., the highest and lowest annual consumed energy belong to the ratio of 1:2 and 1:10, respectively. Whereas from 1:2 to 1:10 ratio, regular downtrend has been occurred to received daylighting factors by the models. According to ANOVA performed on the intensity of daylight’s received height, significant differences were detected in different models with different atrium area ratios.Overall, the results show that ratio of atrium to total building area of 1:4 is the most efficient selection in terms of energy performance, daylighting and thermal comfort.
first_indexed 2024-03-06T04:10:25Z
format Article
id ukm.eprints-9126
institution Universiti Kebangsaan Malaysia
language English
last_indexed 2024-03-06T04:10:25Z
publishDate 2015
publisher Penerbit UKM
record_format dspace
spelling ukm.eprints-91262016-12-14T06:49:03Z http://journalarticle.ukm.my/9126/ Appropriate geometrical ratio modeling of atrium for energy efficiency in office buildings Nasrollahi, N. Abdolahzadeh, S. Litkohi, S. Atrium refers to an open interior space that can be potentially related to an exterior environment. Indeed, atrium is considered as a filter and obstacle blocking undesirable exterior environmental phenomena such as rain, snow and wind. A well designed atrium can contribute to have a significant effect on both; the building's energy performance and indoor environmental conditions. In this paper, the aim is to study the effect of atrium ratio on energy efficiency and comfort of the occupants in an office building in the city of Tehran. In this work, the length to width ratio of the office buildings is identified and the average height of these buildings and validated appropriateness are examined by field studies. The simulation modellings of Design Builder Software is used to model various aspects of the building such as building materials, architecture construction, heating, cooling and lighting systems. One way ANOVA and Duncan’s multiple range tests are used to determine the differences of daylight and compare their averages in different models. It is shown that by decreasing the ratio of atrium to total building area from 1:2 to 1:10, the annual energy consumption reduces i.e., the highest and lowest annual consumed energy belong to the ratio of 1:2 and 1:10, respectively. Whereas from 1:2 to 1:10 ratio, regular downtrend has been occurred to received daylighting factors by the models. According to ANOVA performed on the intensity of daylight’s received height, significant differences were detected in different models with different atrium area ratios.Overall, the results show that ratio of atrium to total building area of 1:4 is the most efficient selection in terms of energy performance, daylighting and thermal comfort. Penerbit UKM 2015 Article PeerReviewed application/pdf en http://journalarticle.ukm.my/9126/1/165-521-1-PB.pdf Nasrollahi, N. and Abdolahzadeh, S. and Litkohi, S. (2015) Appropriate geometrical ratio modeling of atrium for energy efficiency in office buildings. Journal of Building Performance, 6 (1). pp. 95-104. ISSN 2180-2106 http://spaj.ukm.my/jsb/index.php/jbp/issue/view/29
spellingShingle Nasrollahi, N.
Abdolahzadeh, S.
Litkohi, S.
Appropriate geometrical ratio modeling of atrium for energy efficiency in office buildings
title Appropriate geometrical ratio modeling of atrium for energy efficiency in office buildings
title_full Appropriate geometrical ratio modeling of atrium for energy efficiency in office buildings
title_fullStr Appropriate geometrical ratio modeling of atrium for energy efficiency in office buildings
title_full_unstemmed Appropriate geometrical ratio modeling of atrium for energy efficiency in office buildings
title_short Appropriate geometrical ratio modeling of atrium for energy efficiency in office buildings
title_sort appropriate geometrical ratio modeling of atrium for energy efficiency in office buildings
url http://journalarticle.ukm.my/9126/1/165-521-1-PB.pdf
work_keys_str_mv AT nasrollahin appropriategeometricalratiomodelingofatriumforenergyefficiencyinofficebuildings
AT abdolahzadehs appropriategeometricalratiomodelingofatriumforenergyefficiencyinofficebuildings
AT litkohis appropriategeometricalratiomodelingofatriumforenergyefficiencyinofficebuildings