The safety and strength of a novel medial, partial non-threaded pedicle screw: a cadaveric and biomechanical investigation
STUDY DESIGN:: Cadaveric and biomechanical study. OBJECTIVE:: Assess the safety and pullout strength of medial, partial non-threaded thoracic pedicle screws compared to conventional screws. SUMMARY OF BACKGROUND DATA:: The perforation rate of pedicle screws has been reported as high as 41. Nerve inj...
Main Authors: | , , , , |
---|---|
Format: | Article |
Published: |
Lippincott, Williams & Wilkins
2013
|
Subjects: |
_version_ | 1825719962024542208 |
---|---|
author | Kwan, M.K. Chan, C.Y. Saw, L.B. Shanmugam, R. Lenke, L.G. |
author_facet | Kwan, M.K. Chan, C.Y. Saw, L.B. Shanmugam, R. Lenke, L.G. |
author_sort | Kwan, M.K. |
collection | UM |
description | STUDY DESIGN:: Cadaveric and biomechanical study. OBJECTIVE:: Assess the safety and pullout strength of medial, partial non-threaded thoracic pedicle screws compared to conventional screws. SUMMARY OF BACKGROUND DATA:: The perforation rate of pedicle screws has been reported as high as 41. Nerve injury and irritation can result from compression of malpositioned screw on neural structures. METHODS:: Ten fresh cadavers were studied. 5.0 mm and 6.0 mm screws were inserted from T1-T6 and T7-T12 respectively. Pedicle perforations and fractures were recorded upon screw insertion and final positioning (non-threaded portion facing medially) following a wide laminectomy. Pullout strength of novel and conventional screws were then tested using an Instron machine in an artificial bone substitute. RESULTS:: 240 thoracic pedicle screws were inserted. 88.8 (213 screws) were fully contained during screw insertion. There were 5.0 (12 screws) Grade 1 medial perforations and 6.2 (15 screws) Grade 1 lateral perforations during screw insertion. Upon final positioning, 93.8 (225 screws) were fully contained. All Grade 1 medial perforations, which occurred during insertion, were converted to Grade 0. No dural or nerve root injuries occurred. Pedicle split fractures were noted in 6.7 (16 screws). The use of medial, partial non-threaded screws reduced the overall perforation rate from 11.2 to 6.2. The mean pullout load for the 5 mm fully threaded screw vs. medial, partial non-threaded was 1419.3 N±106.1 (1275.8-1538.8 N) and 1336.6 N±44.2 (1293.0-1405.1 N) respectively, whereas 6 mm pullout load averaged 2126.0 N±134.8 (1986.3-2338.3 N) and 2036.5 N±210.0 (1818.4-2355.9 N). The difference was not statistically significant. CONCLUSION:: The use of medial, partial non-threaded pedicle screws reduced the medial perforation rate from 5.0 to 0; however, pullout strength was not significantly reduced. The use of this novel screw can potentially reduce the incidence of nerve injury or irritation following medial pedicle perforations. |
first_indexed | 2024-03-06T05:27:44Z |
format | Article |
id | um.eprints-11087 |
institution | Universiti Malaya |
last_indexed | 2024-03-06T05:27:44Z |
publishDate | 2013 |
publisher | Lippincott, Williams & Wilkins |
record_format | dspace |
spelling | um.eprints-110872014-10-13T01:06:12Z http://eprints.um.edu.my/11087/ The safety and strength of a novel medial, partial non-threaded pedicle screw: a cadaveric and biomechanical investigation Kwan, M.K. Chan, C.Y. Saw, L.B. Shanmugam, R. Lenke, L.G. R Medicine STUDY DESIGN:: Cadaveric and biomechanical study. OBJECTIVE:: Assess the safety and pullout strength of medial, partial non-threaded thoracic pedicle screws compared to conventional screws. SUMMARY OF BACKGROUND DATA:: The perforation rate of pedicle screws has been reported as high as 41. Nerve injury and irritation can result from compression of malpositioned screw on neural structures. METHODS:: Ten fresh cadavers were studied. 5.0 mm and 6.0 mm screws were inserted from T1-T6 and T7-T12 respectively. Pedicle perforations and fractures were recorded upon screw insertion and final positioning (non-threaded portion facing medially) following a wide laminectomy. Pullout strength of novel and conventional screws were then tested using an Instron machine in an artificial bone substitute. RESULTS:: 240 thoracic pedicle screws were inserted. 88.8 (213 screws) were fully contained during screw insertion. There were 5.0 (12 screws) Grade 1 medial perforations and 6.2 (15 screws) Grade 1 lateral perforations during screw insertion. Upon final positioning, 93.8 (225 screws) were fully contained. All Grade 1 medial perforations, which occurred during insertion, were converted to Grade 0. No dural or nerve root injuries occurred. Pedicle split fractures were noted in 6.7 (16 screws). The use of medial, partial non-threaded screws reduced the overall perforation rate from 11.2 to 6.2. The mean pullout load for the 5 mm fully threaded screw vs. medial, partial non-threaded was 1419.3 N±106.1 (1275.8-1538.8 N) and 1336.6 N±44.2 (1293.0-1405.1 N) respectively, whereas 6 mm pullout load averaged 2126.0 N±134.8 (1986.3-2338.3 N) and 2036.5 N±210.0 (1818.4-2355.9 N). The difference was not statistically significant. CONCLUSION:: The use of medial, partial non-threaded pedicle screws reduced the medial perforation rate from 5.0 to 0; however, pullout strength was not significantly reduced. The use of this novel screw can potentially reduce the incidence of nerve injury or irritation following medial pedicle perforations. Lippincott, Williams & Wilkins 2013 Article PeerReviewed Kwan, M.K. and Chan, C.Y. and Saw, L.B. and Shanmugam, R. and Lenke, L.G. (2013) The safety and strength of a novel medial, partial non-threaded pedicle screw: a cadaveric and biomechanical investigation. Journal of Spinal Disorders & Techniques. ISSN 1536-0652, |
spellingShingle | R Medicine Kwan, M.K. Chan, C.Y. Saw, L.B. Shanmugam, R. Lenke, L.G. The safety and strength of a novel medial, partial non-threaded pedicle screw: a cadaveric and biomechanical investigation |
title | The safety and strength of a novel medial, partial non-threaded pedicle screw: a cadaveric and biomechanical investigation |
title_full | The safety and strength of a novel medial, partial non-threaded pedicle screw: a cadaveric and biomechanical investigation |
title_fullStr | The safety and strength of a novel medial, partial non-threaded pedicle screw: a cadaveric and biomechanical investigation |
title_full_unstemmed | The safety and strength of a novel medial, partial non-threaded pedicle screw: a cadaveric and biomechanical investigation |
title_short | The safety and strength of a novel medial, partial non-threaded pedicle screw: a cadaveric and biomechanical investigation |
title_sort | safety and strength of a novel medial partial non threaded pedicle screw a cadaveric and biomechanical investigation |
topic | R Medicine |
work_keys_str_mv | AT kwanmk thesafetyandstrengthofanovelmedialpartialnonthreadedpediclescrewacadavericandbiomechanicalinvestigation AT chancy thesafetyandstrengthofanovelmedialpartialnonthreadedpediclescrewacadavericandbiomechanicalinvestigation AT sawlb thesafetyandstrengthofanovelmedialpartialnonthreadedpediclescrewacadavericandbiomechanicalinvestigation AT shanmugamr thesafetyandstrengthofanovelmedialpartialnonthreadedpediclescrewacadavericandbiomechanicalinvestigation AT lenkelg thesafetyandstrengthofanovelmedialpartialnonthreadedpediclescrewacadavericandbiomechanicalinvestigation AT kwanmk safetyandstrengthofanovelmedialpartialnonthreadedpediclescrewacadavericandbiomechanicalinvestigation AT chancy safetyandstrengthofanovelmedialpartialnonthreadedpediclescrewacadavericandbiomechanicalinvestigation AT sawlb safetyandstrengthofanovelmedialpartialnonthreadedpediclescrewacadavericandbiomechanicalinvestigation AT shanmugamr safetyandstrengthofanovelmedialpartialnonthreadedpediclescrewacadavericandbiomechanicalinvestigation AT lenkelg safetyandstrengthofanovelmedialpartialnonthreadedpediclescrewacadavericandbiomechanicalinvestigation |