Practical performance analysis of an industrial-scale ultrafiltration membrane water treatment plant

Common design and operational issues to evaluate the performance of an ultrafiltration (UF) membrane water treatment plant are highlighted with a case study on an industrial-scale drinking water treatment plant located in Malaysia. This treatment plant has been in operation since February 2013 using...

Full description

Bibliographic Details
Main Authors: Chew, C.M., Aroua, M.K., Hussain, Mohd Azlan, Wan Ismail, W.M.Z.
Format: Article
Language:English
Published: Elsevier 2015
Subjects:
Online Access:http://eprints.um.edu.my/13886/1/Practical_performance_analysis_of_an_industrial-scale_ultrafiltration.pdf
_version_ 1825720432854040576
author Chew, C.M.
Aroua, M.K.
Hussain, Mohd Azlan
Wan Ismail, W.M.Z.
author_facet Chew, C.M.
Aroua, M.K.
Hussain, Mohd Azlan
Wan Ismail, W.M.Z.
author_sort Chew, C.M.
collection UM
description Common design and operational issues to evaluate the performance of an ultrafiltration (UF) membrane water treatment plant are highlighted with a case study on an industrial-scale drinking water treatment plant located in Malaysia. This treatment plant has been in operation since February 2013 using dead-end polyethersulfone UF membrane filtration system to produce up to 14 million litres a day of drinking water to a small township. Literature solutions are compared with the practised solutions and elucidated with the case study. Gaps between literature solutions which are mainly based on lab-scale research and industry practices are identified. Reducing this gap will have vast implication to improve the design and operation of industrial-scale UF treatment system. (C) 2014 Taiwan Institute of Chemical Engineers. Published by Elsevier B.V. All rights reserved.
first_indexed 2024-03-06T05:35:04Z
format Article
id um.eprints-13886
institution Universiti Malaya
language English
last_indexed 2024-03-06T05:35:04Z
publishDate 2015
publisher Elsevier
record_format dspace
spelling um.eprints-138862019-03-19T03:35:42Z http://eprints.um.edu.my/13886/ Practical performance analysis of an industrial-scale ultrafiltration membrane water treatment plant Chew, C.M. Aroua, M.K. Hussain, Mohd Azlan Wan Ismail, W.M.Z. T Technology (General) TP Chemical technology Common design and operational issues to evaluate the performance of an ultrafiltration (UF) membrane water treatment plant are highlighted with a case study on an industrial-scale drinking water treatment plant located in Malaysia. This treatment plant has been in operation since February 2013 using dead-end polyethersulfone UF membrane filtration system to produce up to 14 million litres a day of drinking water to a small township. Literature solutions are compared with the practised solutions and elucidated with the case study. Gaps between literature solutions which are mainly based on lab-scale research and industry practices are identified. Reducing this gap will have vast implication to improve the design and operation of industrial-scale UF treatment system. (C) 2014 Taiwan Institute of Chemical Engineers. Published by Elsevier B.V. All rights reserved. Elsevier 2015-01 Article PeerReviewed application/pdf en http://eprints.um.edu.my/13886/1/Practical_performance_analysis_of_an_industrial-scale_ultrafiltration.pdf Chew, C.M. and Aroua, M.K. and Hussain, Mohd Azlan and Wan Ismail, W.M.Z. (2015) Practical performance analysis of an industrial-scale ultrafiltration membrane water treatment plant. Journal of the Taiwan Institute of Chemical Engineers, 46. pp. 132-139. ISSN 1876-1070, DOI https://doi.org/10.1016/j.jtice.2014.09.013 <https://doi.org/10.1016/j.jtice.2014.09.013>. https://doi.org/10.1016/j.jtice.2014.09.013 doi:10.1016/j.jtice.2014.09.013
spellingShingle T Technology (General)
TP Chemical technology
Chew, C.M.
Aroua, M.K.
Hussain, Mohd Azlan
Wan Ismail, W.M.Z.
Practical performance analysis of an industrial-scale ultrafiltration membrane water treatment plant
title Practical performance analysis of an industrial-scale ultrafiltration membrane water treatment plant
title_full Practical performance analysis of an industrial-scale ultrafiltration membrane water treatment plant
title_fullStr Practical performance analysis of an industrial-scale ultrafiltration membrane water treatment plant
title_full_unstemmed Practical performance analysis of an industrial-scale ultrafiltration membrane water treatment plant
title_short Practical performance analysis of an industrial-scale ultrafiltration membrane water treatment plant
title_sort practical performance analysis of an industrial scale ultrafiltration membrane water treatment plant
topic T Technology (General)
TP Chemical technology
url http://eprints.um.edu.my/13886/1/Practical_performance_analysis_of_an_industrial-scale_ultrafiltration.pdf
work_keys_str_mv AT chewcm practicalperformanceanalysisofanindustrialscaleultrafiltrationmembranewatertreatmentplant
AT arouamk practicalperformanceanalysisofanindustrialscaleultrafiltrationmembranewatertreatmentplant
AT hussainmohdazlan practicalperformanceanalysisofanindustrialscaleultrafiltrationmembranewatertreatmentplant
AT wanismailwmz practicalperformanceanalysisofanindustrialscaleultrafiltrationmembranewatertreatmentplant