Effects of operating parameters on the performance of washing-electrokinetic two stage process as soil remediation method for lead removal

The application of washing-electrokinetic two stage process on remediation of lead (Pb) contaminated soil was investigated. The process consisted of an initial soil washing, followed by an electrokinetic process. The use of electrokinetic process in soil washing could provide additional driving forc...

Full description

Bibliographic Details
Main Authors: Ng, Yee Sern, Sen Gupta, B., Hashim, Mohd Ali
Format: Article
Published: Elsevier 2015
Subjects:
_version_ 1796947006433787904
author Ng, Yee Sern
Sen Gupta, B.
Hashim, Mohd Ali
author_facet Ng, Yee Sern
Sen Gupta, B.
Hashim, Mohd Ali
author_sort Ng, Yee Sern
collection UM
description The application of washing-electrokinetic two stage process on remediation of lead (Pb) contaminated soil was investigated. The process consisted of an initial soil washing, followed by an electrokinetic process. The use of electrokinetic process in soil washing could provide additional driving force for transporting the desorbed Pb away from the soil even in the absence of pore flow. Thus, high usage of wash solution may be mitigated. In this study, the effect of operating conditions such as electric potential difference, wash solution concentration and initial Pb concentration on the feasibility of washing-electrokinetic two stage process on Pb removal was investigated using response surface methodology based on Box-Behnken design. The wash solution used was citric acid and three main aspects were examined, namely: (i) removal efficiency, (ii) effluent generated, and (iii) power consumption. The results revealed that the increase in electric potential difference and wash solution concentration generally enhanced Pb removal efficiency and the interactions of these parameters were significantly positive. However, undesirable high effluent generation and power consumption were also caused by these increments. Optimisation study revealed that 84.14% removal efficiency with zero effluent generation and a power consumption of 2.27 kW h/kg Pb removed could be achieved at 7.58 V and 0.057 M citric acid concentration. In comparison with normal soil washing, washing-electrokinetic two stage process showed an enhancement in removal efficiency by approximate to 16% via electromigration under optimum conditions using similar solution: soil ratio of <0.8 mL:1 g soil. The study reveals that incorporation of electrokinetic process in soil washing is feasible as it not only enhances Pb removal efficiency at minimum wash solution usage with respect to normal soil washing, but also provides in situ Pb recovery in cathode chamber via electrodeposition. (C) 2015 Elsevier B.V. All rights reserved.
first_indexed 2024-03-06T05:40:21Z
format Article
id um.eprints-16133
institution Universiti Malaya
last_indexed 2024-03-06T05:40:21Z
publishDate 2015
publisher Elsevier
record_format dspace
spelling um.eprints-161332018-10-19T08:40:12Z http://eprints.um.edu.my/16133/ Effects of operating parameters on the performance of washing-electrokinetic two stage process as soil remediation method for lead removal Ng, Yee Sern Sen Gupta, B. Hashim, Mohd Ali T Technology (General) TA Engineering (General). Civil engineering (General) The application of washing-electrokinetic two stage process on remediation of lead (Pb) contaminated soil was investigated. The process consisted of an initial soil washing, followed by an electrokinetic process. The use of electrokinetic process in soil washing could provide additional driving force for transporting the desorbed Pb away from the soil even in the absence of pore flow. Thus, high usage of wash solution may be mitigated. In this study, the effect of operating conditions such as electric potential difference, wash solution concentration and initial Pb concentration on the feasibility of washing-electrokinetic two stage process on Pb removal was investigated using response surface methodology based on Box-Behnken design. The wash solution used was citric acid and three main aspects were examined, namely: (i) removal efficiency, (ii) effluent generated, and (iii) power consumption. The results revealed that the increase in electric potential difference and wash solution concentration generally enhanced Pb removal efficiency and the interactions of these parameters were significantly positive. However, undesirable high effluent generation and power consumption were also caused by these increments. Optimisation study revealed that 84.14% removal efficiency with zero effluent generation and a power consumption of 2.27 kW h/kg Pb removed could be achieved at 7.58 V and 0.057 M citric acid concentration. In comparison with normal soil washing, washing-electrokinetic two stage process showed an enhancement in removal efficiency by approximate to 16% via electromigration under optimum conditions using similar solution: soil ratio of <0.8 mL:1 g soil. The study reveals that incorporation of electrokinetic process in soil washing is feasible as it not only enhances Pb removal efficiency at minimum wash solution usage with respect to normal soil washing, but also provides in situ Pb recovery in cathode chamber via electrodeposition. (C) 2015 Elsevier B.V. All rights reserved. Elsevier 2015 Article PeerReviewed Ng, Yee Sern and Sen Gupta, B. and Hashim, Mohd Ali (2015) Effects of operating parameters on the performance of washing-electrokinetic two stage process as soil remediation method for lead removal. Separation and Purification Technology, 156 (2). pp. 403-413. ISSN 1383-5866, DOI https://doi.org/10.1016/j.seppur.2015.10.029 <https://doi.org/10.1016/j.seppur.2015.10.029>. https://doi.org/10.1016/j.seppur.2015.10.029 doi:10.1016/j.seppur.2015.10.029
spellingShingle T Technology (General)
TA Engineering (General). Civil engineering (General)
Ng, Yee Sern
Sen Gupta, B.
Hashim, Mohd Ali
Effects of operating parameters on the performance of washing-electrokinetic two stage process as soil remediation method for lead removal
title Effects of operating parameters on the performance of washing-electrokinetic two stage process as soil remediation method for lead removal
title_full Effects of operating parameters on the performance of washing-electrokinetic two stage process as soil remediation method for lead removal
title_fullStr Effects of operating parameters on the performance of washing-electrokinetic two stage process as soil remediation method for lead removal
title_full_unstemmed Effects of operating parameters on the performance of washing-electrokinetic two stage process as soil remediation method for lead removal
title_short Effects of operating parameters on the performance of washing-electrokinetic two stage process as soil remediation method for lead removal
title_sort effects of operating parameters on the performance of washing electrokinetic two stage process as soil remediation method for lead removal
topic T Technology (General)
TA Engineering (General). Civil engineering (General)
work_keys_str_mv AT ngyeesern effectsofoperatingparametersontheperformanceofwashingelectrokinetictwostageprocessassoilremediationmethodforleadremoval
AT senguptab effectsofoperatingparametersontheperformanceofwashingelectrokinetictwostageprocessassoilremediationmethodforleadremoval
AT hashimmohdali effectsofoperatingparametersontheperformanceofwashingelectrokinetictwostageprocessassoilremediationmethodforleadremoval