High sensitivity surface plasmon resonance (SPR) refractive index sensor in 1.5 μm
A surface plasmon resonance (SPR) based sensor is proposed and demonstrated for operation in the 1500 nm region. The sensor operates by the immersion of microfibers with a 25-μm diameter waist in chemical solutions that have varying external effective refractive indices. The sensor is fabricated usi...