Highly responsive NaCl detector based on inline microfiber Mach–Zehnder interferometer

This paper details the fabrication and performance evaluation of a sodium chloride (NaCl) detector based on an inline microfiber Mach–Zehnder interferometer (IMMZI) that had been fabricated via a glass fiber processing system (Vytran GPX-3400). Spectral characteristics of IMMZIs possessing a variety...

Full description

Bibliographic Details
Main Authors: Jaddoa, M.F., Jasim, Ali Abdulhadi, Razak, M.Z.A., Harun, Sulaiman Wadi, Ahmad, Harith
Format: Article
Published: Elsevier 2016
Subjects:
_version_ 1796947233005895680
author Jaddoa, M.F.
Jasim, Ali Abdulhadi
Razak, M.Z.A.
Harun, Sulaiman Wadi
Ahmad, Harith
author_facet Jaddoa, M.F.
Jasim, Ali Abdulhadi
Razak, M.Z.A.
Harun, Sulaiman Wadi
Ahmad, Harith
author_sort Jaddoa, M.F.
collection UM
description This paper details the fabrication and performance evaluation of a sodium chloride (NaCl) detector based on an inline microfiber Mach–Zehnder interferometer (IMMZI) that had been fabricated via a glass fiber processing system (Vytran GPX-3400). Spectral characteristics of IMMZIs possessing a variety of waist diameters and situated within assorted concentrations of NaCl solutions are also reported. An optimally high responsitivity to NaCl solutions of about 2913.7 nm per refractive-index unit (RIU) was exhibited by an IMMZI with a total length of 34 mm and a tapered waist diameter of 10 μm, in which the RI ranged from 1.31837 to 1.31928.
first_indexed 2024-03-06T05:43:45Z
format Article
id um.eprints-17866
institution Universiti Malaya
last_indexed 2024-03-06T05:43:45Z
publishDate 2016
publisher Elsevier
record_format dspace
spelling um.eprints-178662019-01-02T03:09:20Z http://eprints.um.edu.my/17866/ Highly responsive NaCl detector based on inline microfiber Mach–Zehnder interferometer Jaddoa, M.F. Jasim, Ali Abdulhadi Razak, M.Z.A. Harun, Sulaiman Wadi Ahmad, Harith QC Physics TK Electrical engineering. Electronics Nuclear engineering This paper details the fabrication and performance evaluation of a sodium chloride (NaCl) detector based on an inline microfiber Mach–Zehnder interferometer (IMMZI) that had been fabricated via a glass fiber processing system (Vytran GPX-3400). Spectral characteristics of IMMZIs possessing a variety of waist diameters and situated within assorted concentrations of NaCl solutions are also reported. An optimally high responsitivity to NaCl solutions of about 2913.7 nm per refractive-index unit (RIU) was exhibited by an IMMZI with a total length of 34 mm and a tapered waist diameter of 10 μm, in which the RI ranged from 1.31837 to 1.31928. Elsevier 2016 Article PeerReviewed Jaddoa, M.F. and Jasim, Ali Abdulhadi and Razak, M.Z.A. and Harun, Sulaiman Wadi and Ahmad, Harith (2016) Highly responsive NaCl detector based on inline microfiber Mach–Zehnder interferometer. Sensors and Actuators A: Physical, 237. pp. 56-61. ISSN 0924-4247, DOI https://doi.org/10.1016/j.sna.2015.11.014 <https://doi.org/10.1016/j.sna.2015.11.014>. http://dx.doi.org/10.1016/j.sna.2015.11.014 doi:10.1016/j.sna.2015.11.014
spellingShingle QC Physics
TK Electrical engineering. Electronics Nuclear engineering
Jaddoa, M.F.
Jasim, Ali Abdulhadi
Razak, M.Z.A.
Harun, Sulaiman Wadi
Ahmad, Harith
Highly responsive NaCl detector based on inline microfiber Mach–Zehnder interferometer
title Highly responsive NaCl detector based on inline microfiber Mach–Zehnder interferometer
title_full Highly responsive NaCl detector based on inline microfiber Mach–Zehnder interferometer
title_fullStr Highly responsive NaCl detector based on inline microfiber Mach–Zehnder interferometer
title_full_unstemmed Highly responsive NaCl detector based on inline microfiber Mach–Zehnder interferometer
title_short Highly responsive NaCl detector based on inline microfiber Mach–Zehnder interferometer
title_sort highly responsive nacl detector based on inline microfiber mach zehnder interferometer
topic QC Physics
TK Electrical engineering. Electronics Nuclear engineering
work_keys_str_mv AT jaddoamf highlyresponsivenacldetectorbasedoninlinemicrofibermachzehnderinterferometer
AT jasimaliabdulhadi highlyresponsivenacldetectorbasedoninlinemicrofibermachzehnderinterferometer
AT razakmza highlyresponsivenacldetectorbasedoninlinemicrofibermachzehnderinterferometer
AT harunsulaimanwadi highlyresponsivenacldetectorbasedoninlinemicrofibermachzehnderinterferometer
AT ahmadharith highlyresponsivenacldetectorbasedoninlinemicrofibermachzehnderinterferometer