Optimal placement of unified power flow controller by dynamic implementation of system-variable-based voltage-stability indices to enhance voltage stability

A new approach of unified power flow controller (UPFC) optimal placement in the power system network based on dynamic analysis of voltage stability is presented in this paper. Voltage stability indices (VSIs), called line stability index LQP, voltage collapse point indicators (VCPIs), and line stabi...

Full description

Bibliographic Details
Main Authors: Ahmad, S., Albatsh, F.M., Mekhilef, Saad, Mokhlis, Hazlie
Format: Article
Published: ASTM International 2016
Subjects:
_version_ 1796960433368727552
author Ahmad, S.
Albatsh, F.M.
Mekhilef, Saad
Mokhlis, Hazlie
author_facet Ahmad, S.
Albatsh, F.M.
Mekhilef, Saad
Mokhlis, Hazlie
author_sort Ahmad, S.
collection UM
description A new approach of unified power flow controller (UPFC) optimal placement in the power system network based on dynamic analysis of voltage stability is presented in this paper. Voltage stability indices (VSIs), called line stability index LQP, voltage collapse point indicators (VCPIs), and line stability factor Lmn have been employed to explore the most suitable location for UPFC. The locations of UPFC are identified by dynamically varying loads across all the PQ buses by different percentages to satisfy the real power system conditions. The simulations are conducted in a power system computer-aided design (PSCAD) environment where IEEE-39 bus system has been chosen as case study. The effectiveness of the proposed method has been ensured from the simulation results because UPFC's placement in the obtained locations resulted in an improved voltage stability condition. Furthermore, to verify the suitability of the explored locations, a comparative study has been conducted after placing UPFC in the present locations and other locations obtained using optimization techniques like particle swarm optimization (PSO), differential evolution (DE), genetic algorithm (GA), and bacteria foraging algorithm (BFA). In all the cases, UPFC's placement in the identified locations using the proposed approach has resulted in better voltage stability condition improvement compared to heuristics approaches.
first_indexed 2024-03-06T05:44:31Z
format Article
id um.eprints-18132
institution Universiti Malaya
last_indexed 2024-03-06T05:44:31Z
publishDate 2016
publisher ASTM International
record_format dspace
spelling um.eprints-181322019-10-10T02:37:19Z http://eprints.um.edu.my/18132/ Optimal placement of unified power flow controller by dynamic implementation of system-variable-based voltage-stability indices to enhance voltage stability Ahmad, S. Albatsh, F.M. Mekhilef, Saad Mokhlis, Hazlie TK Electrical engineering. Electronics Nuclear engineering A new approach of unified power flow controller (UPFC) optimal placement in the power system network based on dynamic analysis of voltage stability is presented in this paper. Voltage stability indices (VSIs), called line stability index LQP, voltage collapse point indicators (VCPIs), and line stability factor Lmn have been employed to explore the most suitable location for UPFC. The locations of UPFC are identified by dynamically varying loads across all the PQ buses by different percentages to satisfy the real power system conditions. The simulations are conducted in a power system computer-aided design (PSCAD) environment where IEEE-39 bus system has been chosen as case study. The effectiveness of the proposed method has been ensured from the simulation results because UPFC's placement in the obtained locations resulted in an improved voltage stability condition. Furthermore, to verify the suitability of the explored locations, a comparative study has been conducted after placing UPFC in the present locations and other locations obtained using optimization techniques like particle swarm optimization (PSO), differential evolution (DE), genetic algorithm (GA), and bacteria foraging algorithm (BFA). In all the cases, UPFC's placement in the identified locations using the proposed approach has resulted in better voltage stability condition improvement compared to heuristics approaches. ASTM International 2016 Article PeerReviewed Ahmad, S. and Albatsh, F.M. and Mekhilef, Saad and Mokhlis, Hazlie (2016) Optimal placement of unified power flow controller by dynamic implementation of system-variable-based voltage-stability indices to enhance voltage stability. Journal of Testing and Evaluation, 44 (1). pp. 290-309. ISSN 0090-3973, DOI https://doi.org/10.1520/JTE20140512 <https://doi.org/10.1520/JTE20140512>. http://dx.doi.org/10.1520/JTE20140512 DOI:10.1520/JTE20140512
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
Ahmad, S.
Albatsh, F.M.
Mekhilef, Saad
Mokhlis, Hazlie
Optimal placement of unified power flow controller by dynamic implementation of system-variable-based voltage-stability indices to enhance voltage stability
title Optimal placement of unified power flow controller by dynamic implementation of system-variable-based voltage-stability indices to enhance voltage stability
title_full Optimal placement of unified power flow controller by dynamic implementation of system-variable-based voltage-stability indices to enhance voltage stability
title_fullStr Optimal placement of unified power flow controller by dynamic implementation of system-variable-based voltage-stability indices to enhance voltage stability
title_full_unstemmed Optimal placement of unified power flow controller by dynamic implementation of system-variable-based voltage-stability indices to enhance voltage stability
title_short Optimal placement of unified power flow controller by dynamic implementation of system-variable-based voltage-stability indices to enhance voltage stability
title_sort optimal placement of unified power flow controller by dynamic implementation of system variable based voltage stability indices to enhance voltage stability
topic TK Electrical engineering. Electronics Nuclear engineering
work_keys_str_mv AT ahmads optimalplacementofunifiedpowerflowcontrollerbydynamicimplementationofsystemvariablebasedvoltagestabilityindicestoenhancevoltagestability
AT albatshfm optimalplacementofunifiedpowerflowcontrollerbydynamicimplementationofsystemvariablebasedvoltagestabilityindicestoenhancevoltagestability
AT mekhilefsaad optimalplacementofunifiedpowerflowcontrollerbydynamicimplementationofsystemvariablebasedvoltagestabilityindicestoenhancevoltagestability
AT mokhlishazlie optimalplacementofunifiedpowerflowcontrollerbydynamicimplementationofsystemvariablebasedvoltagestabilityindicestoenhancevoltagestability