Arsenite removal using a pilot system of ultrasound and ultraviolet followed by microfiltration

Batch and continuous-flow pilot tests using ultrasound (US), ultraviolet (UV) and a combination of US and UV were conducted to determine the oxidation rates of arsenite [As(III)]. Compared to the single processes of US or UV, the combined US/UV system was more effective for As(III) oxidation with a...

Full description

Bibliographic Details
Main Authors: Cui, M., Jang, M., Ibrahim, S., Park, B., Cho, E., Khim, J.
Format: Article
Published: Elsevier 2014
Subjects:
_version_ 1796960523101667328
author Cui, M.
Jang, M.
Ibrahim, S.
Park, B.
Cho, E.
Khim, J.
author_facet Cui, M.
Jang, M.
Ibrahim, S.
Park, B.
Cho, E.
Khim, J.
author_sort Cui, M.
collection UM
description Batch and continuous-flow pilot tests using ultrasound (US), ultraviolet (UV) and a combination of US and UV were conducted to determine the oxidation rates of arsenite [As(III)]. Compared to the single processes of US or UV, the combined US/UV system was more effective for As(III) oxidation with a synergy index of more than 1.5. A high rate constant of As(III) removal was obtained as ferrous [Fe(II)] ions existed. Like the pseudo-Fenton reaction, Fe(II) species can participate in the production of additional ·OH by reacting with H2O2 produced by US, before being oxidized to Fe(III). From the results of batch tests, the optimum molar ratio of Fe(II)/As(III) and pH were found to be 83 and 6-9.5, respectively. Similarly, the continuous-flow pilot tests showed that US/UV system could remove As(III) below the regulation [10 μg L(-1) as total As (Astot)] at 91 of molar ratio [Fe(II)/As(III)] and 3-h HRT. The continuous-stirred-tank-reactor (CSTR) modeling showed that the scavenging effect of anionic species (Cl(-) and CO3(2-)) for ·OH might prevail in the single processes, whereas it is insignificant in the combined process. Without using chemicals, microfiltration (MF) was adopted to treat sludge produced in oxidation step. In terms of an engineering aspect, the operational critical flux (CF) and cycle time were also optimized through the continuous-flow tests of MF system. As an energy-utilizing oxidation technique that does not require a catalyst, the combined energy system employing US/UV followed by MF could be a promising alternative for treating As(III) and Fe(II) simultaneously.
first_indexed 2024-03-06T05:45:54Z
format Article
id um.eprints-18636
institution Universiti Malaya
last_indexed 2024-03-06T05:45:54Z
publishDate 2014
publisher Elsevier
record_format dspace
spelling um.eprints-186362018-04-27T03:46:41Z http://eprints.um.edu.my/18636/ Arsenite removal using a pilot system of ultrasound and ultraviolet followed by microfiltration Cui, M. Jang, M. Ibrahim, S. Park, B. Cho, E. Khim, J. TA Engineering (General). Civil engineering (General) Batch and continuous-flow pilot tests using ultrasound (US), ultraviolet (UV) and a combination of US and UV were conducted to determine the oxidation rates of arsenite [As(III)]. Compared to the single processes of US or UV, the combined US/UV system was more effective for As(III) oxidation with a synergy index of more than 1.5. A high rate constant of As(III) removal was obtained as ferrous [Fe(II)] ions existed. Like the pseudo-Fenton reaction, Fe(II) species can participate in the production of additional ·OH by reacting with H2O2 produced by US, before being oxidized to Fe(III). From the results of batch tests, the optimum molar ratio of Fe(II)/As(III) and pH were found to be 83 and 6-9.5, respectively. Similarly, the continuous-flow pilot tests showed that US/UV system could remove As(III) below the regulation [10 μg L(-1) as total As (Astot)] at 91 of molar ratio [Fe(II)/As(III)] and 3-h HRT. The continuous-stirred-tank-reactor (CSTR) modeling showed that the scavenging effect of anionic species (Cl(-) and CO3(2-)) for ·OH might prevail in the single processes, whereas it is insignificant in the combined process. Without using chemicals, microfiltration (MF) was adopted to treat sludge produced in oxidation step. In terms of an engineering aspect, the operational critical flux (CF) and cycle time were also optimized through the continuous-flow tests of MF system. As an energy-utilizing oxidation technique that does not require a catalyst, the combined energy system employing US/UV followed by MF could be a promising alternative for treating As(III) and Fe(II) simultaneously. Elsevier 2014 Article PeerReviewed Cui, M. and Jang, M. and Ibrahim, S. and Park, B. and Cho, E. and Khim, J. (2014) Arsenite removal using a pilot system of ultrasound and ultraviolet followed by microfiltration. Ultrasonics Sonochemistry, 21 (4). pp. 1527-1534. ISSN 1350-4177, DOI https://doi.org/10.1016/j.ultsonch.2014.01.001 <https://doi.org/10.1016/j.ultsonch.2014.01.001>. https://doi.org/10.1016/j.ultsonch.2014.01.001 doi:10.1016/j.ultsonch.2014.01.001
spellingShingle TA Engineering (General). Civil engineering (General)
Cui, M.
Jang, M.
Ibrahim, S.
Park, B.
Cho, E.
Khim, J.
Arsenite removal using a pilot system of ultrasound and ultraviolet followed by microfiltration
title Arsenite removal using a pilot system of ultrasound and ultraviolet followed by microfiltration
title_full Arsenite removal using a pilot system of ultrasound and ultraviolet followed by microfiltration
title_fullStr Arsenite removal using a pilot system of ultrasound and ultraviolet followed by microfiltration
title_full_unstemmed Arsenite removal using a pilot system of ultrasound and ultraviolet followed by microfiltration
title_short Arsenite removal using a pilot system of ultrasound and ultraviolet followed by microfiltration
title_sort arsenite removal using a pilot system of ultrasound and ultraviolet followed by microfiltration
topic TA Engineering (General). Civil engineering (General)
work_keys_str_mv AT cuim arseniteremovalusingapilotsystemofultrasoundandultravioletfollowedbymicrofiltration
AT jangm arseniteremovalusingapilotsystemofultrasoundandultravioletfollowedbymicrofiltration
AT ibrahims arseniteremovalusingapilotsystemofultrasoundandultravioletfollowedbymicrofiltration
AT parkb arseniteremovalusingapilotsystemofultrasoundandultravioletfollowedbymicrofiltration
AT choe arseniteremovalusingapilotsystemofultrasoundandultravioletfollowedbymicrofiltration
AT khimj arseniteremovalusingapilotsystemofultrasoundandultravioletfollowedbymicrofiltration