Effects of low-intensity laser therapy on the stability of orthodontic mini-implants: a randomised controlled clinical trial

Objective: To investigate the effect of low-intensity laser therapy on mini-implant stability using resonance frequency analysis during canine retraction with fixed appliances. Design: A split-mouth randomised clinical trial. Setting: Subjects were recruited and treated in the outpatient clinic, Dep...

Full description

Bibliographic Details
Main Authors: Abohabib, Ahmed Mohamed, Fayed, Mona Mohamed Salaheldin, Labib, Amr H.
Format: Article
Published: Taylor & Francis 2018
Subjects:
_version_ 1796961685712404480
author Abohabib, Ahmed Mohamed
Fayed, Mona Mohamed Salaheldin
Labib, Amr H.
author_facet Abohabib, Ahmed Mohamed
Fayed, Mona Mohamed Salaheldin
Labib, Amr H.
author_sort Abohabib, Ahmed Mohamed
collection UM
description Objective: To investigate the effect of low-intensity laser therapy on mini-implant stability using resonance frequency analysis during canine retraction with fixed appliances. Design: A split-mouth randomised clinical trial. Setting: Subjects were recruited and treated in the outpatient clinic, Department of Orthodontics, Faculty of Dentistry, Cairo University. Participants: Fifteen subjects with mean age 20.9 (±3.4) years who required extraction of maxillary first premolar teeth and mini-implant-supported canine retraction. Methods: Thirty orthodontic mini-implants were inserted bilaterally in the maxillary arches of recruited subjects following alignment and levelling. Mini-implants were immediately loaded with a force of 150 g using nickel titanium coil springs with split-mouth randomisation to a low-intensity laser-treated side and control side. The experimental sides were exposed to low-intensity laser therapy from a diode laser with a wavelength of 940 nm at (0, 7, 14, 21 days) after mini-implant placement. Mini-implant stability was measured using resonance frequency analysis at (0, 1, 2, 3, 4, 6, 8, 10 weeks) after implant placement. Results: A total sample of 28 mini-implants were investigated with 14 in each group. Clinically, both mini-implant groups had the same overall success rate of 78.5%. There were no significant differences in resonance frequency scores between low-intensity laser and control sides from baseline to week 2. However, from week 3 to 10, the low-intensity laser sides showed significantly increased mean resonance frequency values compared to control (P > 0.05). Conclusions: Despite evidence of some significant differences in resonance frequency between mini-implants exposed to low-intensity laser light over a 10 weeks period there were no differences in mini-implant stability. Low-intensity laser light cannot be recommended as a clinically useful adjunct to promoting mini-implant stability during canine retraction.
first_indexed 2024-03-06T05:57:49Z
format Article
id um.eprints-22725
institution Universiti Malaya
last_indexed 2024-03-06T05:57:49Z
publishDate 2018
publisher Taylor & Francis
record_format dspace
spelling um.eprints-227252019-10-14T02:41:06Z http://eprints.um.edu.my/22725/ Effects of low-intensity laser therapy on the stability of orthodontic mini-implants: a randomised controlled clinical trial Abohabib, Ahmed Mohamed Fayed, Mona Mohamed Salaheldin Labib, Amr H. RK Dentistry Objective: To investigate the effect of low-intensity laser therapy on mini-implant stability using resonance frequency analysis during canine retraction with fixed appliances. Design: A split-mouth randomised clinical trial. Setting: Subjects were recruited and treated in the outpatient clinic, Department of Orthodontics, Faculty of Dentistry, Cairo University. Participants: Fifteen subjects with mean age 20.9 (±3.4) years who required extraction of maxillary first premolar teeth and mini-implant-supported canine retraction. Methods: Thirty orthodontic mini-implants were inserted bilaterally in the maxillary arches of recruited subjects following alignment and levelling. Mini-implants were immediately loaded with a force of 150 g using nickel titanium coil springs with split-mouth randomisation to a low-intensity laser-treated side and control side. The experimental sides were exposed to low-intensity laser therapy from a diode laser with a wavelength of 940 nm at (0, 7, 14, 21 days) after mini-implant placement. Mini-implant stability was measured using resonance frequency analysis at (0, 1, 2, 3, 4, 6, 8, 10 weeks) after implant placement. Results: A total sample of 28 mini-implants were investigated with 14 in each group. Clinically, both mini-implant groups had the same overall success rate of 78.5%. There were no significant differences in resonance frequency scores between low-intensity laser and control sides from baseline to week 2. However, from week 3 to 10, the low-intensity laser sides showed significantly increased mean resonance frequency values compared to control (P > 0.05). Conclusions: Despite evidence of some significant differences in resonance frequency between mini-implants exposed to low-intensity laser light over a 10 weeks period there were no differences in mini-implant stability. Low-intensity laser light cannot be recommended as a clinically useful adjunct to promoting mini-implant stability during canine retraction. Taylor & Francis 2018 Article PeerReviewed Abohabib, Ahmed Mohamed and Fayed, Mona Mohamed Salaheldin and Labib, Amr H. (2018) Effects of low-intensity laser therapy on the stability of orthodontic mini-implants: a randomised controlled clinical trial. Journal of Orthodontics, 45 (3). pp. 149-156. ISSN 1465-3125, DOI https://doi.org/10.1080/14653125.2018.1481710 <https://doi.org/10.1080/14653125.2018.1481710>. https://doi.org/10.1080/14653125.2018.1481710 doi:10.1080/14653125.2018.1481710
spellingShingle RK Dentistry
Abohabib, Ahmed Mohamed
Fayed, Mona Mohamed Salaheldin
Labib, Amr H.
Effects of low-intensity laser therapy on the stability of orthodontic mini-implants: a randomised controlled clinical trial
title Effects of low-intensity laser therapy on the stability of orthodontic mini-implants: a randomised controlled clinical trial
title_full Effects of low-intensity laser therapy on the stability of orthodontic mini-implants: a randomised controlled clinical trial
title_fullStr Effects of low-intensity laser therapy on the stability of orthodontic mini-implants: a randomised controlled clinical trial
title_full_unstemmed Effects of low-intensity laser therapy on the stability of orthodontic mini-implants: a randomised controlled clinical trial
title_short Effects of low-intensity laser therapy on the stability of orthodontic mini-implants: a randomised controlled clinical trial
title_sort effects of low intensity laser therapy on the stability of orthodontic mini implants a randomised controlled clinical trial
topic RK Dentistry
work_keys_str_mv AT abohabibahmedmohamed effectsoflowintensitylasertherapyonthestabilityoforthodonticminiimplantsarandomisedcontrolledclinicaltrial
AT fayedmonamohamedsalaheldin effectsoflowintensitylasertherapyonthestabilityoforthodonticminiimplantsarandomisedcontrolledclinicaltrial
AT labibamrh effectsoflowintensitylasertherapyonthestabilityoforthodonticminiimplantsarandomisedcontrolledclinicaltrial