Initial testing of a pixelated silicon detector prototype in proton therapy

As technology continues to develop, external beam radiation therapy is being employed, with increased conformity, to treat smaller targets. As this occurs, the dosimetry methods and tools employed to quantify these fields for treatment also have to evolve to provide increased spatial resolution. The...

Full description

Bibliographic Details
Main Authors: Wroe, Andrew J., McAuley, Grant, Teran, Anthony V., Wong, Jeannie Hsiu Ding, Petasecca, Marco, Lerch, Michael, Slater, James M., Rozenfeld, Anatoly B.
Format: Article
Published: Wiley Open Access 2017
Subjects:
_version_ 1825721937134878720
author Wroe, Andrew J.
McAuley, Grant
Teran, Anthony V.
Wong, Jeannie Hsiu Ding
Petasecca, Marco
Lerch, Michael
Slater, James M.
Rozenfeld, Anatoly B.
author_facet Wroe, Andrew J.
McAuley, Grant
Teran, Anthony V.
Wong, Jeannie Hsiu Ding
Petasecca, Marco
Lerch, Michael
Slater, James M.
Rozenfeld, Anatoly B.
author_sort Wroe, Andrew J.
collection UM
description As technology continues to develop, external beam radiation therapy is being employed, with increased conformity, to treat smaller targets. As this occurs, the dosimetry methods and tools employed to quantify these fields for treatment also have to evolve to provide increased spatial resolution. The team at the University of Wollongong has developed a pixelated silicon detector prototype known as the dose magnifying glass (DMG) for real-time small-field metrology. This device has been tested in photon fields and IMRT. The purpose of this work was to conduct the initial performance tests with proton radiation, using beam energies and modulations typically associated with proton radiosurgery. Depth dose and lateral beam profiles were measured and compared with those collected using a PTW parallel-plate ionization chamber, a PTW proton-specific dosimetry diode, EBT3 Gafchromic film, and Monte Carlo simulations. Measurements of the depth dose profile yielded good agreement when compared with Monte Carlo, diode and ionization chamber. Bragg peak location was measured accurately by the DMG by scanning along the depth dose profile, and the relative response of the DMG at the center of modulation was within 2.5% of that for the PTW dosimetry diode for all energy and modulation combinations tested. Real-time beam profile measurements of a 5 mm 127 MeV proton beam also yielded FWHM and FW90 within ±1 channel (0.1 mm) of the Monte Carlo and EBT3 film data across all depths tested. The DMG tested here proved to be a useful device at measuring depth dose profiles in proton therapy with a stable response across the entire proton spread-out Bragg peak. In addition, the linear array of small sensitive volumes allowed for accurate point and high spatial resolution one-dimensional profile measurements of small radiation fields in real time to be completed with minimal impact from partial volume averaging.
first_indexed 2024-03-06T05:57:58Z
format Article
id um.eprints-22776
institution Universiti Malaya
last_indexed 2024-03-06T05:57:58Z
publishDate 2017
publisher Wiley Open Access
record_format dspace
spelling um.eprints-227762019-10-21T03:58:37Z http://eprints.um.edu.my/22776/ Initial testing of a pixelated silicon detector prototype in proton therapy Wroe, Andrew J. McAuley, Grant Teran, Anthony V. Wong, Jeannie Hsiu Ding Petasecca, Marco Lerch, Michael Slater, James M. Rozenfeld, Anatoly B. R Medicine As technology continues to develop, external beam radiation therapy is being employed, with increased conformity, to treat smaller targets. As this occurs, the dosimetry methods and tools employed to quantify these fields for treatment also have to evolve to provide increased spatial resolution. The team at the University of Wollongong has developed a pixelated silicon detector prototype known as the dose magnifying glass (DMG) for real-time small-field metrology. This device has been tested in photon fields and IMRT. The purpose of this work was to conduct the initial performance tests with proton radiation, using beam energies and modulations typically associated with proton radiosurgery. Depth dose and lateral beam profiles were measured and compared with those collected using a PTW parallel-plate ionization chamber, a PTW proton-specific dosimetry diode, EBT3 Gafchromic film, and Monte Carlo simulations. Measurements of the depth dose profile yielded good agreement when compared with Monte Carlo, diode and ionization chamber. Bragg peak location was measured accurately by the DMG by scanning along the depth dose profile, and the relative response of the DMG at the center of modulation was within 2.5% of that for the PTW dosimetry diode for all energy and modulation combinations tested. Real-time beam profile measurements of a 5 mm 127 MeV proton beam also yielded FWHM and FW90 within ±1 channel (0.1 mm) of the Monte Carlo and EBT3 film data across all depths tested. The DMG tested here proved to be a useful device at measuring depth dose profiles in proton therapy with a stable response across the entire proton spread-out Bragg peak. In addition, the linear array of small sensitive volumes allowed for accurate point and high spatial resolution one-dimensional profile measurements of small radiation fields in real time to be completed with minimal impact from partial volume averaging. Wiley Open Access 2017 Article PeerReviewed Wroe, Andrew J. and McAuley, Grant and Teran, Anthony V. and Wong, Jeannie Hsiu Ding and Petasecca, Marco and Lerch, Michael and Slater, James M. and Rozenfeld, Anatoly B. (2017) Initial testing of a pixelated silicon detector prototype in proton therapy. Journal of Applied Clinical Medical Physics, 18 (5). pp. 315-324. ISSN 1526-9914, DOI https://doi.org/10.1002/acm2.12120 <https://doi.org/10.1002/acm2.12120>. https://doi.org/10.1002/acm2.12120 doi:10.1002/acm2.12120
spellingShingle R Medicine
Wroe, Andrew J.
McAuley, Grant
Teran, Anthony V.
Wong, Jeannie Hsiu Ding
Petasecca, Marco
Lerch, Michael
Slater, James M.
Rozenfeld, Anatoly B.
Initial testing of a pixelated silicon detector prototype in proton therapy
title Initial testing of a pixelated silicon detector prototype in proton therapy
title_full Initial testing of a pixelated silicon detector prototype in proton therapy
title_fullStr Initial testing of a pixelated silicon detector prototype in proton therapy
title_full_unstemmed Initial testing of a pixelated silicon detector prototype in proton therapy
title_short Initial testing of a pixelated silicon detector prototype in proton therapy
title_sort initial testing of a pixelated silicon detector prototype in proton therapy
topic R Medicine
work_keys_str_mv AT wroeandrewj initialtestingofapixelatedsilicondetectorprototypeinprotontherapy
AT mcauleygrant initialtestingofapixelatedsilicondetectorprototypeinprotontherapy
AT terananthonyv initialtestingofapixelatedsilicondetectorprototypeinprotontherapy
AT wongjeanniehsiuding initialtestingofapixelatedsilicondetectorprototypeinprotontherapy
AT petaseccamarco initialtestingofapixelatedsilicondetectorprototypeinprotontherapy
AT lerchmichael initialtestingofapixelatedsilicondetectorprototypeinprotontherapy
AT slaterjamesm initialtestingofapixelatedsilicondetectorprototypeinprotontherapy
AT rozenfeldanatolyb initialtestingofapixelatedsilicondetectorprototypeinprotontherapy