Monte Carlo simulations and analysis of transmitted gamma ray spectra through various tissue phantoms

Studies of radiation interactions with tissue equivalent material find importance in efforts that seek to avoid unjustifiable dose to patients, also in ensuring quality control of for instance nuclear medicine imaging equipment. Use of the Monte Carlo (MC) simulation tool in such characterization pr...

Full description

Bibliographic Details
Main Authors: Moradi, Farhad, Khandaker, Mayeen Uddin, Alrefae, Tareq, Ramazanian, H., Bradley, David Andrew
Format: Article
Published: Elsevier 2019
Subjects:
_version_ 1825722159859761152
author Moradi, Farhad
Khandaker, Mayeen Uddin
Alrefae, Tareq
Ramazanian, H.
Bradley, David Andrew
author_facet Moradi, Farhad
Khandaker, Mayeen Uddin
Alrefae, Tareq
Ramazanian, H.
Bradley, David Andrew
author_sort Moradi, Farhad
collection UM
description Studies of radiation interactions with tissue equivalent material find importance in efforts that seek to avoid unjustifiable dose to patients, also in ensuring quality control of for instance nuclear medicine imaging equipment. Use of the Monte Carlo (MC) simulation tool in such characterization processes allows for the avoidance of costly experiments involving transmitted X- and γ-ray spectrometry. Present work investigates MC simulations of γ-ray transmission through tissue equivalent solid phantoms. Use has been made of a range of radionuclide gamma ray sources, 99m Tc, 131 I, 137 Cs, 60 Co (offering photons in the energy range from a few keV up to low MeV), popularly applied in medicine and in some cases for gauging in industry, obtaining the transmission spectra following their interaction with various phantom materials and thicknesses. In validation of the model, the simulated values of mass attenuation coefficients (μ/ρ) for different phantom materials and thicknesses were found to be in good agreement with reference values (NIST, 2004) to within 1.1% for all material compositions. For all of the primary photon energies and medium thicknesses of interest herein, results show that multiple scattering peaks are generally located at energies lower than 100 keV, although for the larger phantom thicknesses it is more difficult to distinguish single, double and multiple scattering in the gamma spectra. Transmitted photon spectra investigated for water, soft tissue, breast, brain and lung tissue slab phantoms are demonstrated to be practically independent of the phantom material, while a significant difference is observed for the spectra transmitted through bone that was proved to be due to the density effect and not material composition. © 2019 Elsevier Ltd
first_indexed 2024-03-06T06:01:24Z
format Article
id um.eprints-23965
institution Universiti Malaya
last_indexed 2024-03-06T06:01:24Z
publishDate 2019
publisher Elsevier
record_format dspace
spelling um.eprints-239652020-03-04T04:23:38Z http://eprints.um.edu.my/23965/ Monte Carlo simulations and analysis of transmitted gamma ray spectra through various tissue phantoms Moradi, Farhad Khandaker, Mayeen Uddin Alrefae, Tareq Ramazanian, H. Bradley, David Andrew QC Physics Studies of radiation interactions with tissue equivalent material find importance in efforts that seek to avoid unjustifiable dose to patients, also in ensuring quality control of for instance nuclear medicine imaging equipment. Use of the Monte Carlo (MC) simulation tool in such characterization processes allows for the avoidance of costly experiments involving transmitted X- and γ-ray spectrometry. Present work investigates MC simulations of γ-ray transmission through tissue equivalent solid phantoms. Use has been made of a range of radionuclide gamma ray sources, 99m Tc, 131 I, 137 Cs, 60 Co (offering photons in the energy range from a few keV up to low MeV), popularly applied in medicine and in some cases for gauging in industry, obtaining the transmission spectra following their interaction with various phantom materials and thicknesses. In validation of the model, the simulated values of mass attenuation coefficients (μ/ρ) for different phantom materials and thicknesses were found to be in good agreement with reference values (NIST, 2004) to within 1.1% for all material compositions. For all of the primary photon energies and medium thicknesses of interest herein, results show that multiple scattering peaks are generally located at energies lower than 100 keV, although for the larger phantom thicknesses it is more difficult to distinguish single, double and multiple scattering in the gamma spectra. Transmitted photon spectra investigated for water, soft tissue, breast, brain and lung tissue slab phantoms are demonstrated to be practically independent of the phantom material, while a significant difference is observed for the spectra transmitted through bone that was proved to be due to the density effect and not material composition. © 2019 Elsevier Ltd Elsevier 2019 Article PeerReviewed Moradi, Farhad and Khandaker, Mayeen Uddin and Alrefae, Tareq and Ramazanian, H. and Bradley, David Andrew (2019) Monte Carlo simulations and analysis of transmitted gamma ray spectra through various tissue phantoms. Applied Radiation and Isotopes, 146. pp. 120-126. ISSN 0969-8043, DOI https://doi.org/10.1016/j.apradiso.2019.01.031 <https://doi.org/10.1016/j.apradiso.2019.01.031>. https://doi.org/10.1016/j.apradiso.2019.01.031 doi:10.1016/j.apradiso.2019.01.031
spellingShingle QC Physics
Moradi, Farhad
Khandaker, Mayeen Uddin
Alrefae, Tareq
Ramazanian, H.
Bradley, David Andrew
Monte Carlo simulations and analysis of transmitted gamma ray spectra through various tissue phantoms
title Monte Carlo simulations and analysis of transmitted gamma ray spectra through various tissue phantoms
title_full Monte Carlo simulations and analysis of transmitted gamma ray spectra through various tissue phantoms
title_fullStr Monte Carlo simulations and analysis of transmitted gamma ray spectra through various tissue phantoms
title_full_unstemmed Monte Carlo simulations and analysis of transmitted gamma ray spectra through various tissue phantoms
title_short Monte Carlo simulations and analysis of transmitted gamma ray spectra through various tissue phantoms
title_sort monte carlo simulations and analysis of transmitted gamma ray spectra through various tissue phantoms
topic QC Physics
work_keys_str_mv AT moradifarhad montecarlosimulationsandanalysisoftransmittedgammarayspectrathroughvarioustissuephantoms
AT khandakermayeenuddin montecarlosimulationsandanalysisoftransmittedgammarayspectrathroughvarioustissuephantoms
AT alrefaetareq montecarlosimulationsandanalysisoftransmittedgammarayspectrathroughvarioustissuephantoms
AT ramazanianh montecarlosimulationsandanalysisoftransmittedgammarayspectrathroughvarioustissuephantoms
AT bradleydavidandrew montecarlosimulationsandanalysisoftransmittedgammarayspectrathroughvarioustissuephantoms