The Study on Thermal Environment and Airflow Pattern in an UFAD System Under a Cooling Mode

In the present research, an investigation of the UFAD system for thermal comfort has been conducted in a high-rise building located in the tropics. The indoor air conditions including temperature, relative humidity, air velocity, and mean radiant temperature have been obtained by conducting the fiel...

Full description

Bibliographic Details
Main Authors: Yau, Yat Huang, Chuah, Keng H., Siew, M.T.
Format: Article
Published: Springer 2020
Subjects:
_version_ 1796962058654187520
author Yau, Yat Huang
Chuah, Keng H.
Siew, M.T.
author_facet Yau, Yat Huang
Chuah, Keng H.
Siew, M.T.
author_sort Yau, Yat Huang
collection UM
description In the present research, an investigation of the UFAD system for thermal comfort has been conducted in a high-rise building located in the tropics. The indoor air conditions including temperature, relative humidity, air velocity, and mean radiant temperature have been obtained by conducting the fieldwork while the clothing insulation value and the metabolic rate of the occupants have been obtained by observing the occupants, where these data were used to obtain the predicted mean vote (PMV) and the predicted percentage dissatisfied (PPD) of the examined areas. In addition, the effects of the airflow pattern in the indoor thermal comfort have been investigated, where two different types of diffusers have been compared in order to find out which diffuser can provide a better thermal comfort to the occupants. The FloEFD simulation software is used to simulate the airflow pattern of these diffusers and to analyze the indoor air conditions of the UFAD system and also to examine the local mean age value. Based on the results obtained, the average PMV is approximately − 1.5 for each examined area, where a proper design of heating, ventilation, and air-conditioning system in a hot and humid country, the PMV result should be approximately equal to − 1. As for the PPD, the range of the PPD obtained falls in between 27.4 and 67.5%, in which it indicates that about more than half of the occupants have dissatisfied with the indoor conditions in the examined building. © 2019, King Fahd University of Petroleum & Minerals.
first_indexed 2024-03-06T06:03:23Z
format Article
id um.eprints-24659
institution Universiti Malaya
last_indexed 2024-03-06T06:03:23Z
publishDate 2020
publisher Springer
record_format dspace
spelling um.eprints-246592020-06-05T00:37:26Z http://eprints.um.edu.my/24659/ The Study on Thermal Environment and Airflow Pattern in an UFAD System Under a Cooling Mode Yau, Yat Huang Chuah, Keng H. Siew, M.T. TJ Mechanical engineering and machinery In the present research, an investigation of the UFAD system for thermal comfort has been conducted in a high-rise building located in the tropics. The indoor air conditions including temperature, relative humidity, air velocity, and mean radiant temperature have been obtained by conducting the fieldwork while the clothing insulation value and the metabolic rate of the occupants have been obtained by observing the occupants, where these data were used to obtain the predicted mean vote (PMV) and the predicted percentage dissatisfied (PPD) of the examined areas. In addition, the effects of the airflow pattern in the indoor thermal comfort have been investigated, where two different types of diffusers have been compared in order to find out which diffuser can provide a better thermal comfort to the occupants. The FloEFD simulation software is used to simulate the airflow pattern of these diffusers and to analyze the indoor air conditions of the UFAD system and also to examine the local mean age value. Based on the results obtained, the average PMV is approximately − 1.5 for each examined area, where a proper design of heating, ventilation, and air-conditioning system in a hot and humid country, the PMV result should be approximately equal to − 1. As for the PPD, the range of the PPD obtained falls in between 27.4 and 67.5%, in which it indicates that about more than half of the occupants have dissatisfied with the indoor conditions in the examined building. © 2019, King Fahd University of Petroleum & Minerals. Springer 2020 Article PeerReviewed Yau, Yat Huang and Chuah, Keng H. and Siew, M.T. (2020) The Study on Thermal Environment and Airflow Pattern in an UFAD System Under a Cooling Mode. Arabian Journal for Science and Engineering, 45 (2). pp. 891-908. ISSN 2193-567X, DOI https://doi.org/10.1007/s13369-019-04184-z <https://doi.org/10.1007/s13369-019-04184-z>. https://doi.org/10.1007/s13369-019-04184-z doi:10.1007/s13369-019-04184-z
spellingShingle TJ Mechanical engineering and machinery
Yau, Yat Huang
Chuah, Keng H.
Siew, M.T.
The Study on Thermal Environment and Airflow Pattern in an UFAD System Under a Cooling Mode
title The Study on Thermal Environment and Airflow Pattern in an UFAD System Under a Cooling Mode
title_full The Study on Thermal Environment and Airflow Pattern in an UFAD System Under a Cooling Mode
title_fullStr The Study on Thermal Environment and Airflow Pattern in an UFAD System Under a Cooling Mode
title_full_unstemmed The Study on Thermal Environment and Airflow Pattern in an UFAD System Under a Cooling Mode
title_short The Study on Thermal Environment and Airflow Pattern in an UFAD System Under a Cooling Mode
title_sort study on thermal environment and airflow pattern in an ufad system under a cooling mode
topic TJ Mechanical engineering and machinery
work_keys_str_mv AT yauyathuang thestudyonthermalenvironmentandairflowpatterninanufadsystemunderacoolingmode
AT chuahkengh thestudyonthermalenvironmentandairflowpatterninanufadsystemunderacoolingmode
AT siewmt thestudyonthermalenvironmentandairflowpatterninanufadsystemunderacoolingmode
AT yauyathuang studyonthermalenvironmentandairflowpatterninanufadsystemunderacoolingmode
AT chuahkengh studyonthermalenvironmentandairflowpatterninanufadsystemunderacoolingmode
AT siewmt studyonthermalenvironmentandairflowpatterninanufadsystemunderacoolingmode