An innovative survey poles configuration: an alternative 3-D volume calibrating system

The purpose of this study is to develop an alternative method for calibrating a threedimensional volume. The new calibration frame uses a set of four poles, consisting of 20 control points. An experiment was conducted to compare the result obtained using two methods of calibration, the Peak calibrat...

Full description

Bibliographic Details
Main Authors: Rambely, A.S., Abu Osman, Noor Azuan, Wan Abas, Wan Abu Bakar, Usman, J., Yusof, M.S.
Format: Article
Language:English
Published: 2003
Subjects:
Online Access:http://eprints.um.edu.my/4442/1/An_innovative_survey_poles_configuration_An_alternative_3-D_volume_calibrating_system.pdf
_version_ 1825718942979588096
author Rambely, A.S.
Abu Osman, Noor Azuan
Wan Abas, Wan Abu Bakar
Usman, J.
Yusof, M.S.
author_facet Rambely, A.S.
Abu Osman, Noor Azuan
Wan Abas, Wan Abu Bakar
Usman, J.
Yusof, M.S.
author_sort Rambely, A.S.
collection UM
description The purpose of this study is to develop an alternative method for calibrating a threedimensional volume. The new calibration frame uses a set of four poles, consisting of 20 control points. An experiment was conducted to compare the result obtained using two methods of calibration, the Peak calibration frame (the control) and the ISN-UM survey poles system (the new reference frame). It was found that the results obtained from the ISN-UM calibration frame are comparable to those obtained using the Peak calibration frame, despite the differences in the locations and the numbers of control points, as well as the physical characteristics of both structures.
first_indexed 2024-03-06T05:12:00Z
format Article
id um.eprints-4442
institution Universiti Malaya
language English
last_indexed 2024-03-06T05:12:00Z
publishDate 2003
record_format dspace
spelling um.eprints-44422019-02-07T08:32:31Z http://eprints.um.edu.my/4442/ An innovative survey poles configuration: an alternative 3-D volume calibrating system Rambely, A.S. Abu Osman, Noor Azuan Wan Abas, Wan Abu Bakar Usman, J. Yusof, M.S. TA Engineering (General). Civil engineering (General) The purpose of this study is to develop an alternative method for calibrating a threedimensional volume. The new calibration frame uses a set of four poles, consisting of 20 control points. An experiment was conducted to compare the result obtained using two methods of calibration, the Peak calibration frame (the control) and the ISN-UM survey poles system (the new reference frame). It was found that the results obtained from the ISN-UM calibration frame are comparable to those obtained using the Peak calibration frame, despite the differences in the locations and the numbers of control points, as well as the physical characteristics of both structures. 2003 Article PeerReviewed application/pdf en http://eprints.um.edu.my/4442/1/An_innovative_survey_poles_configuration_An_alternative_3-D_volume_calibrating_system.pdf Rambely, A.S. and Abu Osman, Noor Azuan and Wan Abas, Wan Abu Bakar and Usman, J. and Yusof, M.S. (2003) An innovative survey poles configuration: an alternative 3-D volume calibrating system. Jurnal Teknologi. http://www.google.com.my/url?sa=t&rct=j&q=&esrc=s&source=web&cd=1&cad=rja&ved=0CCQQFjAA&url=http%3A%2F%2Fwww.jurnalteknologi.utm.my%2Findex.php%2Fjurnalteknologi%2Farticle%2Fdownload%2F482%2F472&ei=7B6TULuIO4aTiAf2nIGICA&usg=AFQjCNG_CT9t-EIaKqRrbKjfNO5sCC
spellingShingle TA Engineering (General). Civil engineering (General)
Rambely, A.S.
Abu Osman, Noor Azuan
Wan Abas, Wan Abu Bakar
Usman, J.
Yusof, M.S.
An innovative survey poles configuration: an alternative 3-D volume calibrating system
title An innovative survey poles configuration: an alternative 3-D volume calibrating system
title_full An innovative survey poles configuration: an alternative 3-D volume calibrating system
title_fullStr An innovative survey poles configuration: an alternative 3-D volume calibrating system
title_full_unstemmed An innovative survey poles configuration: an alternative 3-D volume calibrating system
title_short An innovative survey poles configuration: an alternative 3-D volume calibrating system
title_sort innovative survey poles configuration an alternative 3 d volume calibrating system
topic TA Engineering (General). Civil engineering (General)
url http://eprints.um.edu.my/4442/1/An_innovative_survey_poles_configuration_An_alternative_3-D_volume_calibrating_system.pdf
work_keys_str_mv AT rambelyas aninnovativesurveypolesconfigurationanalternative3dvolumecalibratingsystem
AT abuosmannoorazuan aninnovativesurveypolesconfigurationanalternative3dvolumecalibratingsystem
AT wanabaswanabubakar aninnovativesurveypolesconfigurationanalternative3dvolumecalibratingsystem
AT usmanj aninnovativesurveypolesconfigurationanalternative3dvolumecalibratingsystem
AT yusofms aninnovativesurveypolesconfigurationanalternative3dvolumecalibratingsystem
AT rambelyas innovativesurveypolesconfigurationanalternative3dvolumecalibratingsystem
AT abuosmannoorazuan innovativesurveypolesconfigurationanalternative3dvolumecalibratingsystem
AT wanabaswanabubakar innovativesurveypolesconfigurationanalternative3dvolumecalibratingsystem
AT usmanj innovativesurveypolesconfigurationanalternative3dvolumecalibratingsystem
AT yusofms innovativesurveypolesconfigurationanalternative3dvolumecalibratingsystem