Simultaneous spectrophotometric determination of copper, nickel, and zinc using 1-(2-thiazolylazo)-2-naphthol in the presence of triton x-100 using chemometric methods
Multivariate models were developed for the simultaneous spectrophotometric determination of copper (II), nickel (II) and zinc (II) in water with 1-(2-thiazolylazo)-2-naphthol as chromogenic reagent in the presence of Triton X-100. To overcome the drawback of spectral interferences, principal compone...
Main Authors: | , , , , |
---|---|
Format: | Article |
Published: |
2009
|
Subjects: |
_version_ | 1825719184211836928 |
---|---|
author | Low, K.H. Mohd, M.A. Misran, M. Md Abas, M.R. Zain, Sharifuddin Md |
author_facet | Low, K.H. Mohd, M.A. Misran, M. Md Abas, M.R. Zain, Sharifuddin Md |
author_sort | Low, K.H. |
collection | UM |
description | Multivariate models were developed for the simultaneous spectrophotometric determination of copper (II), nickel (II) and zinc (II) in water with 1-(2-thiazolylazo)-2-naphthol as chromogenic reagent in the presence of Triton X-100. To overcome the drawback of spectral interferences, principal component regression (PCR) and partial least square (PLS) multivariate calibration approaches were applied. Performances were validated with several test sets, and their results were then compared. In general, no significant difference in analytical performance between PLS and PCR models. The root mean square error of prediction (RMSEP) using three components for Cu 2+, Ni 2+ and Zn 2+ were 0.018, 0.010, 0.011 ppm, respectively. Figures of merit such as sensitivity, analytical sensitivity, limit of detection (LOD) were also estimated. High reliability was achieved when the proposed procedure was applied to simultaneous determination of Cu 2+, Ni 2+ and Zn 2+ in synthetic mixture and tap water. |
first_indexed | 2024-03-06T05:15:48Z |
format | Article |
id | um.eprints-6036 |
institution | Universiti Malaya |
last_indexed | 2024-03-06T05:15:48Z |
publishDate | 2009 |
record_format | dspace |
spelling | um.eprints-60362019-08-28T03:06:08Z http://eprints.um.edu.my/6036/ Simultaneous spectrophotometric determination of copper, nickel, and zinc using 1-(2-thiazolylazo)-2-naphthol in the presence of triton x-100 using chemometric methods Low, K.H. Mohd, M.A. Misran, M. Md Abas, M.R. Zain, Sharifuddin Md QD Chemistry Multivariate models were developed for the simultaneous spectrophotometric determination of copper (II), nickel (II) and zinc (II) in water with 1-(2-thiazolylazo)-2-naphthol as chromogenic reagent in the presence of Triton X-100. To overcome the drawback of spectral interferences, principal component regression (PCR) and partial least square (PLS) multivariate calibration approaches were applied. Performances were validated with several test sets, and their results were then compared. In general, no significant difference in analytical performance between PLS and PCR models. The root mean square error of prediction (RMSEP) using three components for Cu 2+, Ni 2+ and Zn 2+ were 0.018, 0.010, 0.011 ppm, respectively. Figures of merit such as sensitivity, analytical sensitivity, limit of detection (LOD) were also estimated. High reliability was achieved when the proposed procedure was applied to simultaneous determination of Cu 2+, Ni 2+ and Zn 2+ in synthetic mixture and tap water. 2009 Article PeerReviewed Low, K.H. and Mohd, M.A. and Misran, M. and Md Abas, M.R. and Zain, Sharifuddin Md (2009) Simultaneous spectrophotometric determination of copper, nickel, and zinc using 1-(2-thiazolylazo)-2-naphthol in the presence of triton x-100 using chemometric methods. Journal of the Korean Chemical Society, 53 (6). pp. 717-726. ISSN 1017-2548, DOI https://doi.org/10.5012/jkcs.2009.53.6.717 <https://doi.org/10.5012/jkcs.2009.53.6.717>. http://www.scopus.com/inward/record.url?eid=2-s2.0-73549120192&partnerID=40&md5=4b3ec145804486e8af171e41da1e6625 10.5012/jkcs.2009.53.6.717 |
spellingShingle | QD Chemistry Low, K.H. Mohd, M.A. Misran, M. Md Abas, M.R. Zain, Sharifuddin Md Simultaneous spectrophotometric determination of copper, nickel, and zinc using 1-(2-thiazolylazo)-2-naphthol in the presence of triton x-100 using chemometric methods |
title | Simultaneous spectrophotometric determination of copper, nickel, and zinc using 1-(2-thiazolylazo)-2-naphthol in the presence of triton x-100 using chemometric methods |
title_full | Simultaneous spectrophotometric determination of copper, nickel, and zinc using 1-(2-thiazolylazo)-2-naphthol in the presence of triton x-100 using chemometric methods |
title_fullStr | Simultaneous spectrophotometric determination of copper, nickel, and zinc using 1-(2-thiazolylazo)-2-naphthol in the presence of triton x-100 using chemometric methods |
title_full_unstemmed | Simultaneous spectrophotometric determination of copper, nickel, and zinc using 1-(2-thiazolylazo)-2-naphthol in the presence of triton x-100 using chemometric methods |
title_short | Simultaneous spectrophotometric determination of copper, nickel, and zinc using 1-(2-thiazolylazo)-2-naphthol in the presence of triton x-100 using chemometric methods |
title_sort | simultaneous spectrophotometric determination of copper nickel and zinc using 1 2 thiazolylazo 2 naphthol in the presence of triton x 100 using chemometric methods |
topic | QD Chemistry |
work_keys_str_mv | AT lowkh simultaneousspectrophotometricdeterminationofcoppernickelandzincusing12thiazolylazo2naphtholinthepresenceoftritonx100usingchemometricmethods AT mohdma simultaneousspectrophotometricdeterminationofcoppernickelandzincusing12thiazolylazo2naphtholinthepresenceoftritonx100usingchemometricmethods AT misranm simultaneousspectrophotometricdeterminationofcoppernickelandzincusing12thiazolylazo2naphtholinthepresenceoftritonx100usingchemometricmethods AT mdabasmr simultaneousspectrophotometricdeterminationofcoppernickelandzincusing12thiazolylazo2naphtholinthepresenceoftritonx100usingchemometricmethods AT zainsharifuddinmd simultaneousspectrophotometricdeterminationofcoppernickelandzincusing12thiazolylazo2naphtholinthepresenceoftritonx100usingchemometricmethods |