Buoyancy-assisted mixed convective flow over backward-facing step in a vertical duct using nanofluids

Laminar mixed convective buoyancy assisting flow through a two-dimensional vertical duct with a backward-facing step using nanofluids as a medium is numerically simulated using finite volume technique. Different types of nanoparticles such as Au, Ag, Al2O3, Cu, CuO, diamond, SiO2 and TiO2 with 5 vo...

Full description

Bibliographic Details
Main Authors: Mohammed, H.A., Al-Aswadi, A.A., Yusoff, M.Z., Saidur, Rahman
Format: Article
Published: Springer Verlag 2012
Subjects:
_version_ 1825719226743128064
author Mohammed, H.A.
Al-Aswadi, A.A.
Yusoff, M.Z.
Saidur, Rahman
author_facet Mohammed, H.A.
Al-Aswadi, A.A.
Yusoff, M.Z.
Saidur, Rahman
author_sort Mohammed, H.A.
collection UM
description Laminar mixed convective buoyancy assisting flow through a two-dimensional vertical duct with a backward-facing step using nanofluids as a medium is numerically simulated using finite volume technique. Different types of nanoparticles such as Au, Ag, Al2O3, Cu, CuO, diamond, SiO2 and TiO2 with 5 volume fraction are used. The wall downstream of the step was maintained at a uniform wall temperature, while the straight wall that forms the other side of the duct was maintained at constant temperature equivalent to the inlet fluid temperature. The walls upstream of the step and the backward-facing step were considered as adiabatic surfaces. The duct has a step height of 4.9 mm and an expansion ratio of 1.942, while the total length in the downstream of the step is 0.5 m. The downstream wall was fixed at uniform wall temperature 0 a parts per thousand currency sign Delta Ta parts per thousand currency sign 30 A degrees C, which was higher than the inlet flow temperature. The Reynolds number in the range of 75 a parts per thousand currency sign Re a parts per thousand currency sign 225 was considered. It is found that a recirculation region was developed straight behind the backward-facing step which appeared between the edge of the step and few millimeters before the corner which connect the step and the downstream wall. In the few millimeters gap between the recirculation region and the downstream wall, a U-turn flow was developed opposite to the recirculation flow which mixed with the unrecirculated flow and traveled along the channel. Two maximum and one minimum peaks in Nusselt number were developed along the heated downstream wall. It is inferred that Au nanofluid has the highest maximum peaks while diamond nanofluid has the highest minimum peak. Nanofluids with a higher Prandtl number have a higher peak of Nusselt numbers after the separation and the recirculation flow disappeared.
first_indexed 2024-03-06T05:16:27Z
format Article
id um.eprints-6287
institution Universiti Malaya
last_indexed 2024-03-06T05:16:27Z
publishDate 2012
publisher Springer Verlag
record_format dspace
spelling um.eprints-62872019-11-27T08:24:30Z http://eprints.um.edu.my/6287/ Buoyancy-assisted mixed convective flow over backward-facing step in a vertical duct using nanofluids Mohammed, H.A. Al-Aswadi, A.A. Yusoff, M.Z. Saidur, Rahman TA Engineering (General). Civil engineering (General) TJ Mechanical engineering and machinery Laminar mixed convective buoyancy assisting flow through a two-dimensional vertical duct with a backward-facing step using nanofluids as a medium is numerically simulated using finite volume technique. Different types of nanoparticles such as Au, Ag, Al2O3, Cu, CuO, diamond, SiO2 and TiO2 with 5 volume fraction are used. The wall downstream of the step was maintained at a uniform wall temperature, while the straight wall that forms the other side of the duct was maintained at constant temperature equivalent to the inlet fluid temperature. The walls upstream of the step and the backward-facing step were considered as adiabatic surfaces. The duct has a step height of 4.9 mm and an expansion ratio of 1.942, while the total length in the downstream of the step is 0.5 m. The downstream wall was fixed at uniform wall temperature 0 a parts per thousand currency sign Delta Ta parts per thousand currency sign 30 A degrees C, which was higher than the inlet flow temperature. The Reynolds number in the range of 75 a parts per thousand currency sign Re a parts per thousand currency sign 225 was considered. It is found that a recirculation region was developed straight behind the backward-facing step which appeared between the edge of the step and few millimeters before the corner which connect the step and the downstream wall. In the few millimeters gap between the recirculation region and the downstream wall, a U-turn flow was developed opposite to the recirculation flow which mixed with the unrecirculated flow and traveled along the channel. Two maximum and one minimum peaks in Nusselt number were developed along the heated downstream wall. It is inferred that Au nanofluid has the highest maximum peaks while diamond nanofluid has the highest minimum peak. Nanofluids with a higher Prandtl number have a higher peak of Nusselt numbers after the separation and the recirculation flow disappeared. Springer Verlag 2012 Article PeerReviewed Mohammed, H.A. and Al-Aswadi, A.A. and Yusoff, M.Z. and Saidur, Rahman (2012) Buoyancy-assisted mixed convective flow over backward-facing step in a vertical duct using nanofluids. Thermophysics and Aeromechanics, 19 (1). pp. 33-52. ISSN 0869-8643, DOI https://doi.org/10.1134/s0869864312010040 <https://doi.org/10.1134/s0869864312010040>. https://doi.org/10.1134/S0869864312010040 doi:10.1134/s0869864312010040
spellingShingle TA Engineering (General). Civil engineering (General)
TJ Mechanical engineering and machinery
Mohammed, H.A.
Al-Aswadi, A.A.
Yusoff, M.Z.
Saidur, Rahman
Buoyancy-assisted mixed convective flow over backward-facing step in a vertical duct using nanofluids
title Buoyancy-assisted mixed convective flow over backward-facing step in a vertical duct using nanofluids
title_full Buoyancy-assisted mixed convective flow over backward-facing step in a vertical duct using nanofluids
title_fullStr Buoyancy-assisted mixed convective flow over backward-facing step in a vertical duct using nanofluids
title_full_unstemmed Buoyancy-assisted mixed convective flow over backward-facing step in a vertical duct using nanofluids
title_short Buoyancy-assisted mixed convective flow over backward-facing step in a vertical duct using nanofluids
title_sort buoyancy assisted mixed convective flow over backward facing step in a vertical duct using nanofluids
topic TA Engineering (General). Civil engineering (General)
TJ Mechanical engineering and machinery
work_keys_str_mv AT mohammedha buoyancyassistedmixedconvectiveflowoverbackwardfacingstepinaverticalductusingnanofluids
AT alaswadiaa buoyancyassistedmixedconvectiveflowoverbackwardfacingstepinaverticalductusingnanofluids
AT yusoffmz buoyancyassistedmixedconvectiveflowoverbackwardfacingstepinaverticalductusingnanofluids
AT saidurrahman buoyancyassistedmixedconvectiveflowoverbackwardfacingstepinaverticalductusingnanofluids