Energy, economics and environmental analysis for chillers in office buildings

Chillers consume a major share of total air conditioning energy use in commercial and industrial buildings for space conditioning to get thermal comfort for a country. In this paper, energy consumption by chillers has been estimated using data collected by walkthrough energy audit for Malaysian offi...

Full description

Bibliographic Details
Main Author: Saidur, Rahman
Format: Article
Published: Energy Education Science and Technology Part a-Energy Science and Research 2010
Subjects:
_version_ 1796945463933403136
author Saidur, Rahman
author_facet Saidur, Rahman
author_sort Saidur, Rahman
collection UM
description Chillers consume a major share of total air conditioning energy use in commercial and industrial buildings for space conditioning to get thermal comfort for a country. In this paper, energy consumption by chillers has been estimated using data collected by walkthrough energy audit for Malaysian office buildings. It has been found that chillers use about 42,285MWh and 84,569MWh of electric energy for 50 and 100 loadings in an institutional buildings. As chillers are major energy users, energy savings measure such as use of energy efficient chillers and VSDs in chillers cooling load reductions have been applied to reduce their energy consumptions. It has been found that 90MWh-896MWh of energy can be saved for using energy efficient chillers for different percentage of loadings. Along with energy savings, US57,314 as a bill savings can be achieved for high efficient chillers for 50 chillers loading. Study found that 35,975 MWh energy and US2,302,431 bill can be saved for 60 of speed reductions using VSD. It was also found that payback periods for this energy saving option for chillers are economically viable. Along with energy savings, emission reductions and cost of avoided carbon associated with energy savings have been estimated and presented in this paper.
first_indexed 2024-03-06T05:17:03Z
format Article
id um.eprints-6741
institution Universiti Malaya
last_indexed 2024-03-06T05:17:03Z
publishDate 2010
publisher Energy Education Science and Technology Part a-Energy Science and Research
record_format dspace
spelling um.eprints-67412019-10-25T06:11:01Z http://eprints.um.edu.my/6741/ Energy, economics and environmental analysis for chillers in office buildings Saidur, Rahman TA Engineering (General). Civil engineering (General) TJ Mechanical engineering and machinery Chillers consume a major share of total air conditioning energy use in commercial and industrial buildings for space conditioning to get thermal comfort for a country. In this paper, energy consumption by chillers has been estimated using data collected by walkthrough energy audit for Malaysian office buildings. It has been found that chillers use about 42,285MWh and 84,569MWh of electric energy for 50 and 100 loadings in an institutional buildings. As chillers are major energy users, energy savings measure such as use of energy efficient chillers and VSDs in chillers cooling load reductions have been applied to reduce their energy consumptions. It has been found that 90MWh-896MWh of energy can be saved for using energy efficient chillers for different percentage of loadings. Along with energy savings, US57,314 as a bill savings can be achieved for high efficient chillers for 50 chillers loading. Study found that 35,975 MWh energy and US2,302,431 bill can be saved for 60 of speed reductions using VSD. It was also found that payback periods for this energy saving option for chillers are economically viable. Along with energy savings, emission reductions and cost of avoided carbon associated with energy savings have been estimated and presented in this paper. Energy Education Science and Technology Part a-Energy Science and Research 2010 Article PeerReviewed Saidur, Rahman (2010) Energy, economics and environmental analysis for chillers in office buildings. Energy Education Science and Technology Part a-Energy Science and Research, 25 (1-2). pp. 1-16. ISSN 1308-772X, https://www.silascience.com/articles/05042012152457.pdf
spellingShingle TA Engineering (General). Civil engineering (General)
TJ Mechanical engineering and machinery
Saidur, Rahman
Energy, economics and environmental analysis for chillers in office buildings
title Energy, economics and environmental analysis for chillers in office buildings
title_full Energy, economics and environmental analysis for chillers in office buildings
title_fullStr Energy, economics and environmental analysis for chillers in office buildings
title_full_unstemmed Energy, economics and environmental analysis for chillers in office buildings
title_short Energy, economics and environmental analysis for chillers in office buildings
title_sort energy economics and environmental analysis for chillers in office buildings
topic TA Engineering (General). Civil engineering (General)
TJ Mechanical engineering and machinery
work_keys_str_mv AT saidurrahman energyeconomicsandenvironmentalanalysisforchillersinofficebuildings