Analysis and experiment of centrifugal force for microfluidic ELISA CD platform

This paper presents an analysis and experiment of centrifugal force for microfluidic Enzyme-Linked Immunosorbent Assay (ELISA) on a compact-disc (CD) platform. The ELISA CD was designed based on the centrifugal force as a driving force while capillary force acts as preventing barrier. The CD compose...

Full description

Bibliographic Details
Main Authors: Ibrahim, F., Jahanshahi, P., Abd Rahman, N., Abdul Kahar, M.K.B., Madou, M., Nozari, A.A., Soin, N., Md Dawal, S.Z., Abi Samra, K.
Format: Conference or Workshop Item
Language:English
Published: 2010
Subjects:
Online Access:http://eprints.um.edu.my/9255/1/Analysis_and_experiment_of_centrifugal_force_for_microfluidic_ELISA_CD_platform______________________.pdf
_version_ 1825719675952037888
author Ibrahim, F.
Jahanshahi, P.
Abd Rahman, N.
Abdul Kahar, M.K.B.
Madou, M.
Nozari, A.A.
Soin, N.
Md Dawal, S.Z.
Abi Samra, K.
author_facet Ibrahim, F.
Jahanshahi, P.
Abd Rahman, N.
Abdul Kahar, M.K.B.
Madou, M.
Nozari, A.A.
Soin, N.
Md Dawal, S.Z.
Abi Samra, K.
author_sort Ibrahim, F.
collection UM
description This paper presents an analysis and experiment of centrifugal force for microfluidic Enzyme-Linked Immunosorbent Assay (ELISA) on a compact-disc (CD) platform. The ELISA CD was designed based on the centrifugal force as a driving force while capillary force acts as preventing barrier. The CD composed of 2 layers: the substrate layer is made of PMMA and the top layer is laminated with an Adhesive Sealing Films (ASF) or thermal seal. The PMMA substrate was fabricated by CNC micromachining. The ELISA CD consists of 7 reservoirs: waste, detection, serum, conjugate, washing solution, substrate and stopping solution. In the experiment, the reservoirs were filled with colour liquid and the fluid flow behaviour of the liquid in the CD was studied and monitored by a customized CD spin stand system equipped with visualization system. The experimental test results show an average of 9 error when compared with the theoretical calculation of burst frequency for all the reservoirs. © 2010 IEEE.
first_indexed 2024-03-06T05:23:22Z
format Conference or Workshop Item
id um.eprints-9255
institution Universiti Malaya
language English
last_indexed 2024-03-06T05:23:22Z
publishDate 2010
record_format dspace
spelling um.eprints-92552017-11-01T05:32:23Z http://eprints.um.edu.my/9255/ Analysis and experiment of centrifugal force for microfluidic ELISA CD platform Ibrahim, F. Jahanshahi, P. Abd Rahman, N. Abdul Kahar, M.K.B. Madou, M. Nozari, A.A. Soin, N. Md Dawal, S.Z. Abi Samra, K. T Technology (General) TA Engineering (General). Civil engineering (General) This paper presents an analysis and experiment of centrifugal force for microfluidic Enzyme-Linked Immunosorbent Assay (ELISA) on a compact-disc (CD) platform. The ELISA CD was designed based on the centrifugal force as a driving force while capillary force acts as preventing barrier. The CD composed of 2 layers: the substrate layer is made of PMMA and the top layer is laminated with an Adhesive Sealing Films (ASF) or thermal seal. The PMMA substrate was fabricated by CNC micromachining. The ELISA CD consists of 7 reservoirs: waste, detection, serum, conjugate, washing solution, substrate and stopping solution. In the experiment, the reservoirs were filled with colour liquid and the fluid flow behaviour of the liquid in the CD was studied and monitored by a customized CD spin stand system equipped with visualization system. The experimental test results show an average of 9 error when compared with the theoretical calculation of burst frequency for all the reservoirs. © 2010 IEEE. 2010 Conference or Workshop Item PeerReviewed application/pdf en http://eprints.um.edu.my/9255/1/Analysis_and_experiment_of_centrifugal_force_for_microfluidic_ELISA_CD_platform______________________.pdf Ibrahim, F. and Jahanshahi, P. and Abd Rahman, N. and Abdul Kahar, M.K.B. and Madou, M. and Nozari, A.A. and Soin, N. and Md Dawal, S.Z. and Abi Samra, K. (2010) Analysis and experiment of centrifugal force for microfluidic ELISA CD platform. In: 2010 IEEE EMBS Conference on Biomedical Engineering and Sciences, IECBES 2010, 2010, Kuala Lumpur. http://www.scopus.com/inward/record.url?eid=2-s2.0-79955425333&partnerID=40&md5=4d7108bfac60ee9bfcddc4e7c86efa83 ieeexplore.ieee.org/xpls/absall.jsp?arnumber=5742282
spellingShingle T Technology (General)
TA Engineering (General). Civil engineering (General)
Ibrahim, F.
Jahanshahi, P.
Abd Rahman, N.
Abdul Kahar, M.K.B.
Madou, M.
Nozari, A.A.
Soin, N.
Md Dawal, S.Z.
Abi Samra, K.
Analysis and experiment of centrifugal force for microfluidic ELISA CD platform
title Analysis and experiment of centrifugal force for microfluidic ELISA CD platform
title_full Analysis and experiment of centrifugal force for microfluidic ELISA CD platform
title_fullStr Analysis and experiment of centrifugal force for microfluidic ELISA CD platform
title_full_unstemmed Analysis and experiment of centrifugal force for microfluidic ELISA CD platform
title_short Analysis and experiment of centrifugal force for microfluidic ELISA CD platform
title_sort analysis and experiment of centrifugal force for microfluidic elisa cd platform
topic T Technology (General)
TA Engineering (General). Civil engineering (General)
url http://eprints.um.edu.my/9255/1/Analysis_and_experiment_of_centrifugal_force_for_microfluidic_ELISA_CD_platform______________________.pdf
work_keys_str_mv AT ibrahimf analysisandexperimentofcentrifugalforceformicrofluidicelisacdplatform
AT jahanshahip analysisandexperimentofcentrifugalforceformicrofluidicelisacdplatform
AT abdrahmann analysisandexperimentofcentrifugalforceformicrofluidicelisacdplatform
AT abdulkaharmkb analysisandexperimentofcentrifugalforceformicrofluidicelisacdplatform
AT madoum analysisandexperimentofcentrifugalforceformicrofluidicelisacdplatform
AT nozariaa analysisandexperimentofcentrifugalforceformicrofluidicelisacdplatform
AT soinn analysisandexperimentofcentrifugalforceformicrofluidicelisacdplatform
AT mddawalsz analysisandexperimentofcentrifugalforceformicrofluidicelisacdplatform
AT abisamrak analysisandexperimentofcentrifugalforceformicrofluidicelisacdplatform