Performance evaluation of water Jet Pump for Nozzle to throat area ratios on suction lift

"The experiment was about to study of water jet pumps with different diameters and nozzle-to-throat area ratios. Most experimental studies on water jet pumps mainly carried out to assess the maximum efficiency. But maximum efficiency occurs when the suction lift is relatively small for a given...

Full description

Bibliographic Details
Main Authors: Md. Mizanur Rahman, Md. Assad-Uz-zaman, Mohammad Mashud
Format: Article
Language:English
Published: 2014
Subjects:
Online Access:https://eprints.ums.edu.my/id/eprint/19537/1/Performance%20Evaluation%20of%20Water%20Jet%20Pump%20for%20Nozzle%20to%20Throat%20Area%20Ratios%20on%20Suction%20Lift.pdf
_version_ 1825713405985554432
author Md. Mizanur Rahman
Md. Assad-Uz-zaman
Mohammad Mashud
author_facet Md. Mizanur Rahman
Md. Assad-Uz-zaman
Mohammad Mashud
author_sort Md. Mizanur Rahman
collection UMS
description "The experiment was about to study of water jet pumps with different diameters and nozzle-to-throat area ratios. Most experimental studies on water jet pumps mainly carried out to assess the maximum efficiency. But maximum efficiency occurs when the suction lift is relatively small for a given head loss through the pump, which implies, when the suction flow rate is maximum. However, suction lift is inversely proportional to flow rate. But in the field of application there are many cases (such as drainage, dredging, well-pumping and other systems) where suction lift is more important factor than any other for water jet pumps, which gives importance to the assessment of depending factor of suction lift of water jet pumps. Six different jet pumps of two different nominal diameter each of three different nozzle to throat area ratio were made to carry out this experiment. The results revealed that the nozzle-to-throat area ratio was an important parameter to characterize the suction lift of the jet pumps, but nominal diameter had a negligible play role.
first_indexed 2024-03-06T02:56:04Z
format Article
id ums.eprints-19537
institution Universiti Malaysia Sabah
language English
last_indexed 2024-03-06T02:56:04Z
publishDate 2014
record_format dspace
spelling ums.eprints-195372018-03-22T02:05:12Z https://eprints.ums.edu.my/id/eprint/19537/ Performance evaluation of water Jet Pump for Nozzle to throat area ratios on suction lift Md. Mizanur Rahman Md. Assad-Uz-zaman Mohammad Mashud TJ Mechanical engineering and machinery "The experiment was about to study of water jet pumps with different diameters and nozzle-to-throat area ratios. Most experimental studies on water jet pumps mainly carried out to assess the maximum efficiency. But maximum efficiency occurs when the suction lift is relatively small for a given head loss through the pump, which implies, when the suction flow rate is maximum. However, suction lift is inversely proportional to flow rate. But in the field of application there are many cases (such as drainage, dredging, well-pumping and other systems) where suction lift is more important factor than any other for water jet pumps, which gives importance to the assessment of depending factor of suction lift of water jet pumps. Six different jet pumps of two different nominal diameter each of three different nozzle to throat area ratio were made to carry out this experiment. The results revealed that the nozzle-to-throat area ratio was an important parameter to characterize the suction lift of the jet pumps, but nominal diameter had a negligible play role. 2014 Article PeerReviewed text en https://eprints.ums.edu.my/id/eprint/19537/1/Performance%20Evaluation%20of%20Water%20Jet%20Pump%20for%20Nozzle%20to%20Throat%20Area%20Ratios%20on%20Suction%20Lift.pdf Md. Mizanur Rahman and Md. Assad-Uz-zaman and Mohammad Mashud (2014) Performance evaluation of water Jet Pump for Nozzle to throat area ratios on suction lift. International Journal of Mechanical & Mechatronics Engineering IJMME, 14 (3). pp. 45-47.
spellingShingle TJ Mechanical engineering and machinery
Md. Mizanur Rahman
Md. Assad-Uz-zaman
Mohammad Mashud
Performance evaluation of water Jet Pump for Nozzle to throat area ratios on suction lift
title Performance evaluation of water Jet Pump for Nozzle to throat area ratios on suction lift
title_full Performance evaluation of water Jet Pump for Nozzle to throat area ratios on suction lift
title_fullStr Performance evaluation of water Jet Pump for Nozzle to throat area ratios on suction lift
title_full_unstemmed Performance evaluation of water Jet Pump for Nozzle to throat area ratios on suction lift
title_short Performance evaluation of water Jet Pump for Nozzle to throat area ratios on suction lift
title_sort performance evaluation of water jet pump for nozzle to throat area ratios on suction lift
topic TJ Mechanical engineering and machinery
url https://eprints.ums.edu.my/id/eprint/19537/1/Performance%20Evaluation%20of%20Water%20Jet%20Pump%20for%20Nozzle%20to%20Throat%20Area%20Ratios%20on%20Suction%20Lift.pdf
work_keys_str_mv AT mdmizanurrahman performanceevaluationofwaterjetpumpfornozzletothroatarearatiosonsuctionlift
AT mdassaduzzaman performanceevaluationofwaterjetpumpfornozzletothroatarearatiosonsuctionlift
AT mohammadmashud performanceevaluationofwaterjetpumpfornozzletothroatarearatiosonsuctionlift