Optimisation frequency design of Eddy current testing in titanium and nickel metal with difference thickness

This paper is to find the optimisation frequency for designed non-destructive testing (NDT) metal instrument. The testing technique is Eddy Current Technique (ECT), where Titanium (Ti) and Nickel (Ni) metals in 100mm X 100mm and with different type of thickness (1.5mm, 3mm and 5mm) dimension were ch...

Full description

Bibliographic Details
Main Authors: Elya Alias, Fauziah Sulaiman, Abu Bakar Abdul Rahman
Format: Article
Language:English
Published: 2018
Subjects:
Online Access:https://eprints.ums.edu.my/id/eprint/22127/1/Optimisation%20frequency%20design%20of%20Eddy%20current%20testing%20in%20titanium%20and%20nickel%20metal%20with%20difference%20thickness.pdf
_version_ 1796910102008037376
author Elya Alias
Fauziah Sulaiman
Abu Bakar Abdul Rahman
author_facet Elya Alias
Fauziah Sulaiman
Abu Bakar Abdul Rahman
author_sort Elya Alias
collection UMS
description This paper is to find the optimisation frequency for designed non-destructive testing (NDT) metal instrument. The testing technique is Eddy Current Technique (ECT), where Titanium (Ti) and Nickel (Ni) metals in 100mm X 100mm and with different type of thickness (1.5mm, 3mm and 5mm) dimension were chosen as the metal testing. Three different kind of thickness in each metal were tested to identified the optimal frequency for the instrument with identical artificial defect that constructed on the metal testing. The input frequencies were ranged between 250kHz - 3.5MHz and a dual-sensors were designed and established to gather the output. The output signals of the voltage of testing from the sensor circuit then compared to analyse the optimal of range frequency for the testing instrument. The result of this research showed that the nondestructive metal testing instrument of dual- sensor by using eddy current method can be used to find different defect for Titanium (Ti) and Nickel (Ni) metal. The optimal frequencies for Titanium was 2.83MHz and Nickel was 2.85MHz. The categorisation of thickness on metal for the eddy current testing instrument is suitable at 2.83MHz for Titanium and 2.85MHz which are also known as optimal frequency.
first_indexed 2024-03-06T02:59:27Z
format Article
id ums.eprints-22127
institution Universiti Malaysia Sabah
language English
last_indexed 2024-03-06T02:59:27Z
publishDate 2018
record_format dspace
spelling ums.eprints-221272019-06-11T06:08:00Z https://eprints.ums.edu.my/id/eprint/22127/ Optimisation frequency design of Eddy current testing in titanium and nickel metal with difference thickness Elya Alias Fauziah Sulaiman Abu Bakar Abdul Rahman QD Chemistry This paper is to find the optimisation frequency for designed non-destructive testing (NDT) metal instrument. The testing technique is Eddy Current Technique (ECT), where Titanium (Ti) and Nickel (Ni) metals in 100mm X 100mm and with different type of thickness (1.5mm, 3mm and 5mm) dimension were chosen as the metal testing. Three different kind of thickness in each metal were tested to identified the optimal frequency for the instrument with identical artificial defect that constructed on the metal testing. The input frequencies were ranged between 250kHz - 3.5MHz and a dual-sensors were designed and established to gather the output. The output signals of the voltage of testing from the sensor circuit then compared to analyse the optimal of range frequency for the testing instrument. The result of this research showed that the nondestructive metal testing instrument of dual- sensor by using eddy current method can be used to find different defect for Titanium (Ti) and Nickel (Ni) metal. The optimal frequencies for Titanium was 2.83MHz and Nickel was 2.85MHz. The categorisation of thickness on metal for the eddy current testing instrument is suitable at 2.83MHz for Titanium and 2.85MHz which are also known as optimal frequency. 2018 Article PeerReviewed text en https://eprints.ums.edu.my/id/eprint/22127/1/Optimisation%20frequency%20design%20of%20Eddy%20current%20testing%20in%20titanium%20and%20nickel%20metal%20with%20difference%20thickness.pdf Elya Alias and Fauziah Sulaiman and Abu Bakar Abdul Rahman (2018) Optimisation frequency design of Eddy current testing in titanium and nickel metal with difference thickness. Global Journal of Engineering Science and Research Management, 5 (4). pp. 24-31. ISSN 2349-4506 https://dx.doi.org/10.5281/zenodo.1222130
spellingShingle QD Chemistry
Elya Alias
Fauziah Sulaiman
Abu Bakar Abdul Rahman
Optimisation frequency design of Eddy current testing in titanium and nickel metal with difference thickness
title Optimisation frequency design of Eddy current testing in titanium and nickel metal with difference thickness
title_full Optimisation frequency design of Eddy current testing in titanium and nickel metal with difference thickness
title_fullStr Optimisation frequency design of Eddy current testing in titanium and nickel metal with difference thickness
title_full_unstemmed Optimisation frequency design of Eddy current testing in titanium and nickel metal with difference thickness
title_short Optimisation frequency design of Eddy current testing in titanium and nickel metal with difference thickness
title_sort optimisation frequency design of eddy current testing in titanium and nickel metal with difference thickness
topic QD Chemistry
url https://eprints.ums.edu.my/id/eprint/22127/1/Optimisation%20frequency%20design%20of%20Eddy%20current%20testing%20in%20titanium%20and%20nickel%20metal%20with%20difference%20thickness.pdf
work_keys_str_mv AT elyaalias optimisationfrequencydesignofeddycurrenttestingintitaniumandnickelmetalwithdifferencethickness
AT fauziahsulaiman optimisationfrequencydesignofeddycurrenttestingintitaniumandnickelmetalwithdifferencethickness
AT abubakarabdulrahman optimisationfrequencydesignofeddycurrenttestingintitaniumandnickelmetalwithdifferencethickness