A study of mechanism for the prevention of cold inflow into Chimneys using wire mesh

Cold air inflow has significant effect on a natural draft air cooled heat exchanger (NDACHE) chimney. To study the mechanism for the prevention of cold inflow into NDACHE chimney's, in total seven configuration of experiments were carried out In the prototype models for different heat loads at...

Full description

Bibliographic Details
Main Authors: Chu, Chi Ming, Sivakumar Kumaresan, Tham Heng Jin
Format: Research Report
Language:English
Published: Universiti Malaysia Sabah 2013
Subjects:
Online Access:https://eprints.ums.edu.my/id/eprint/22800/1/A%20study%20of%20mechanism%20for%20the%20prevention%20of%20cold%20inflow%20into%20Chimneys%20using%20wire%20mesh.pdf
_version_ 1825713664173277184
author Chu, Chi Ming
Sivakumar Kumaresan
Tham Heng Jin
author_facet Chu, Chi Ming
Sivakumar Kumaresan
Tham Heng Jin
author_sort Chu, Chi Ming
collection UMS
description Cold air inflow has significant effect on a natural draft air cooled heat exchanger (NDACHE) chimney. To study the mechanism for the prevention of cold inflow into NDACHE chimney's, in total seven configuration of experiments were carried out In the prototype models for different heat loads at approximately 0.7SkW to 1.25kW. The effect of wire mesh screen on the chimney performance had also determined. Temperature and air velocity were measured for the configurations and heat loads. It was found that the top only, Top and Middle and Middle only installations were able to maintain draft velocity to within 3.0% of , the control experiment draft velocity in spite of the resistance of the mesh. It was also found that configurations utilizing mesh at the bottom had experienced a drop is draft velocity by up to 50% from the control. The smoke flow visualization tests clearly proved that cold air inflow phenomenon exits and can be countered with the installation of wire mesh at the top of the model. In the second phase of the project, the wire mesh of 3 different apertures and two chimney height were tested. Large aperture tended to allow more cold inflow and draft was directly proportional to chimney height. CFD runs were also done for the prototypes to explain the cause of wire mesh serving as repellent of cold inflow.
first_indexed 2024-03-06T03:00:03Z
format Research Report
id ums.eprints-22800
institution Universiti Malaysia Sabah
language English
last_indexed 2024-03-06T03:00:03Z
publishDate 2013
publisher Universiti Malaysia Sabah
record_format dspace
spelling ums.eprints-228002019-07-18T13:50:12Z https://eprints.ums.edu.my/id/eprint/22800/ A study of mechanism for the prevention of cold inflow into Chimneys using wire mesh Chu, Chi Ming Sivakumar Kumaresan Tham Heng Jin TA Engineering (General). Civil engineering (General) Cold air inflow has significant effect on a natural draft air cooled heat exchanger (NDACHE) chimney. To study the mechanism for the prevention of cold inflow into NDACHE chimney's, in total seven configuration of experiments were carried out In the prototype models for different heat loads at approximately 0.7SkW to 1.25kW. The effect of wire mesh screen on the chimney performance had also determined. Temperature and air velocity were measured for the configurations and heat loads. It was found that the top only, Top and Middle and Middle only installations were able to maintain draft velocity to within 3.0% of , the control experiment draft velocity in spite of the resistance of the mesh. It was also found that configurations utilizing mesh at the bottom had experienced a drop is draft velocity by up to 50% from the control. The smoke flow visualization tests clearly proved that cold air inflow phenomenon exits and can be countered with the installation of wire mesh at the top of the model. In the second phase of the project, the wire mesh of 3 different apertures and two chimney height were tested. Large aperture tended to allow more cold inflow and draft was directly proportional to chimney height. CFD runs were also done for the prototypes to explain the cause of wire mesh serving as repellent of cold inflow. Universiti Malaysia Sabah 2013 Research Report NonPeerReviewed text en https://eprints.ums.edu.my/id/eprint/22800/1/A%20study%20of%20mechanism%20for%20the%20prevention%20of%20cold%20inflow%20into%20Chimneys%20using%20wire%20mesh.pdf Chu, Chi Ming and Sivakumar Kumaresan and Tham Heng Jin (2013) A study of mechanism for the prevention of cold inflow into Chimneys using wire mesh. (Unpublished)
spellingShingle TA Engineering (General). Civil engineering (General)
Chu, Chi Ming
Sivakumar Kumaresan
Tham Heng Jin
A study of mechanism for the prevention of cold inflow into Chimneys using wire mesh
title A study of mechanism for the prevention of cold inflow into Chimneys using wire mesh
title_full A study of mechanism for the prevention of cold inflow into Chimneys using wire mesh
title_fullStr A study of mechanism for the prevention of cold inflow into Chimneys using wire mesh
title_full_unstemmed A study of mechanism for the prevention of cold inflow into Chimneys using wire mesh
title_short A study of mechanism for the prevention of cold inflow into Chimneys using wire mesh
title_sort study of mechanism for the prevention of cold inflow into chimneys using wire mesh
topic TA Engineering (General). Civil engineering (General)
url https://eprints.ums.edu.my/id/eprint/22800/1/A%20study%20of%20mechanism%20for%20the%20prevention%20of%20cold%20inflow%20into%20Chimneys%20using%20wire%20mesh.pdf
work_keys_str_mv AT chuchiming astudyofmechanismforthepreventionofcoldinflowintochimneysusingwiremesh
AT sivakumarkumaresan astudyofmechanismforthepreventionofcoldinflowintochimneysusingwiremesh
AT thamhengjin astudyofmechanismforthepreventionofcoldinflowintochimneysusingwiremesh
AT chuchiming studyofmechanismforthepreventionofcoldinflowintochimneysusingwiremesh
AT sivakumarkumaresan studyofmechanismforthepreventionofcoldinflowintochimneysusingwiremesh
AT thamhengjin studyofmechanismforthepreventionofcoldinflowintochimneysusingwiremesh