Dosimetric characteristics of fabricated germanium doped optical fibres for a postal audit of therapy electron beams

The dosimetric characteristics of germanium (Ge) doped optical fibres are investigated as a potential dosimetric alternative for electron beam therapy postal audits. The dosimetric characteristics of 6 mol% Ge-doped optical fibres fabricated as cylindrical fibres (CF) and flat fibres (FF) are establ...

Full description

Bibliographic Details
Main Authors: Abdullah, N., Bradley, D. A., Nisbet, A., Kamarul Zaman, Z., Deraman, S. S., Mohd Noor, N.
Format: Article
Published: Elsevier 2022
_version_ 1796984005370839040
author Abdullah, N.
Bradley, D. A.
Nisbet, A.
Kamarul Zaman, Z.
Deraman, S. S.
Mohd Noor, N.
author_facet Abdullah, N.
Bradley, D. A.
Nisbet, A.
Kamarul Zaman, Z.
Deraman, S. S.
Mohd Noor, N.
author_sort Abdullah, N.
collection UPM
description The dosimetric characteristics of germanium (Ge) doped optical fibres are investigated as a potential dosimetric alternative for electron beam therapy postal audits. The dosimetric characteristics of 6 mol% Ge-doped optical fibres fabricated as cylindrical fibres (CF) and flat fibres (FF) are established in terms of signal fading, linearity of dose-response, beam energy- and dose rate dependence. Pilot electron beam therapy audit study irradiations are made with a linear accelerator located at the Royal Surrey County Hospital, applying International Atomic Energy Agency (IAEA) standard irradiation procedures for reference and non-reference conditions. Results for the CF and FF show fading of 26% and 20% respectively at 120 days post-irradiation. For a 6 MeV electron beam the dose-response is observed to be linear over the dose range 1–3 Gy, the least determination coefficient, R2, being 0.985. The results of the electron beam therapy audit are within the tolerance limit of 5% recommended by the International Commission on Radiation Units and Measurements (ICRU) Report No. 24, with a maximum deviation of 4% for FF at a 6 MeV electron beam under non-reference conditions. In conclusion, the fabricated Ge-doped optical fibres are seen to offer suitability for use as an alternative dosimeter to TLD-100 in electron beam therapy postal audit.
first_indexed 2024-03-06T11:14:25Z
format Article
id upm.eprints-101008
institution Universiti Putra Malaysia
last_indexed 2024-03-06T11:14:25Z
publishDate 2022
publisher Elsevier
record_format dspace
spelling upm.eprints-1010082023-07-12T08:33:12Z http://psasir.upm.edu.my/id/eprint/101008/ Dosimetric characteristics of fabricated germanium doped optical fibres for a postal audit of therapy electron beams Abdullah, N. Bradley, D. A. Nisbet, A. Kamarul Zaman, Z. Deraman, S. S. Mohd Noor, N. The dosimetric characteristics of germanium (Ge) doped optical fibres are investigated as a potential dosimetric alternative for electron beam therapy postal audits. The dosimetric characteristics of 6 mol% Ge-doped optical fibres fabricated as cylindrical fibres (CF) and flat fibres (FF) are established in terms of signal fading, linearity of dose-response, beam energy- and dose rate dependence. Pilot electron beam therapy audit study irradiations are made with a linear accelerator located at the Royal Surrey County Hospital, applying International Atomic Energy Agency (IAEA) standard irradiation procedures for reference and non-reference conditions. Results for the CF and FF show fading of 26% and 20% respectively at 120 days post-irradiation. For a 6 MeV electron beam the dose-response is observed to be linear over the dose range 1–3 Gy, the least determination coefficient, R2, being 0.985. The results of the electron beam therapy audit are within the tolerance limit of 5% recommended by the International Commission on Radiation Units and Measurements (ICRU) Report No. 24, with a maximum deviation of 4% for FF at a 6 MeV electron beam under non-reference conditions. In conclusion, the fabricated Ge-doped optical fibres are seen to offer suitability for use as an alternative dosimeter to TLD-100 in electron beam therapy postal audit. Elsevier 2022-11 Article PeerReviewed Abdullah, N. and Bradley, D. A. and Nisbet, A. and Kamarul Zaman, Z. and Deraman, S. S. and Mohd Noor, N. (2022) Dosimetric characteristics of fabricated germanium doped optical fibres for a postal audit of therapy electron beams. Radiation Physics and Chemistry, 200. art. no. 110346. pp. 1-7. ISSN 0969-806X https://www.sciencedirect.com/science/article/pii/S0969806X22003899#:~:text=The%20dosimetric%20characteristics%20of%206,energy%2D%20and%20dose%20rate%20dependence. 10.1016/j.radphyschem.2022.110346
spellingShingle Abdullah, N.
Bradley, D. A.
Nisbet, A.
Kamarul Zaman, Z.
Deraman, S. S.
Mohd Noor, N.
Dosimetric characteristics of fabricated germanium doped optical fibres for a postal audit of therapy electron beams
title Dosimetric characteristics of fabricated germanium doped optical fibres for a postal audit of therapy electron beams
title_full Dosimetric characteristics of fabricated germanium doped optical fibres for a postal audit of therapy electron beams
title_fullStr Dosimetric characteristics of fabricated germanium doped optical fibres for a postal audit of therapy electron beams
title_full_unstemmed Dosimetric characteristics of fabricated germanium doped optical fibres for a postal audit of therapy electron beams
title_short Dosimetric characteristics of fabricated germanium doped optical fibres for a postal audit of therapy electron beams
title_sort dosimetric characteristics of fabricated germanium doped optical fibres for a postal audit of therapy electron beams
work_keys_str_mv AT abdullahn dosimetriccharacteristicsoffabricatedgermaniumdopedopticalfibresforapostalauditoftherapyelectronbeams
AT bradleyda dosimetriccharacteristicsoffabricatedgermaniumdopedopticalfibresforapostalauditoftherapyelectronbeams
AT nisbeta dosimetriccharacteristicsoffabricatedgermaniumdopedopticalfibresforapostalauditoftherapyelectronbeams
AT kamarulzamanz dosimetriccharacteristicsoffabricatedgermaniumdopedopticalfibresforapostalauditoftherapyelectronbeams
AT deramanss dosimetriccharacteristicsoffabricatedgermaniumdopedopticalfibresforapostalauditoftherapyelectronbeams
AT mohdnoorn dosimetriccharacteristicsoffabricatedgermaniumdopedopticalfibresforapostalauditoftherapyelectronbeams