A flow-through optical fibre reflectance sensor for the detection of lead ion based on immobilised gallocynine
A flow-through spectrophotometric sensor for the determination of lead at trace level using immobilised gallocynine as the reagent phase is proposed. Gallocynine is physically adsorbed onto XAD-7. This method provided a wide linear range of 1 × 10-1 to 1 × 103 ppm and detection limit of 0.06 ppm. Th...
Main Authors: | , |
---|---|
Format: | Article |
Language: | English |
Published: |
Elsevier
2003
|
Online Access: | http://psasir.upm.edu.my/id/eprint/112425/3/112425.pdf |
_version_ | 1825940129063108608 |
---|---|
author | Yusof, Nor Azah Ahmad, Musa |
author_facet | Yusof, Nor Azah Ahmad, Musa |
author_sort | Yusof, Nor Azah |
collection | UPM |
description | A flow-through spectrophotometric sensor for the determination of lead at trace level using immobilised gallocynine as the reagent phase is proposed. Gallocynine is physically adsorbed onto XAD-7. This method provided a wide linear range of 1 × 10-1 to 1 × 103 ppm and detection limit of 0.06 ppm. This method also showed a reproducible result with relative standard deviation (R.S.D.) of 1.64% and response time of ∼5 min. The response towards lead was also reversible using acidified KNO3 as the regenerating solution. Interference studies showed that Hg(II) and Ag(I) significantly interfered during the determination. |
first_indexed | 2025-03-07T12:56:44Z |
format | Article |
id | upm.eprints-112425 |
institution | Universiti Putra Malaysia |
language | English |
last_indexed | 2025-03-07T12:56:44Z |
publishDate | 2003 |
publisher | Elsevier |
record_format | dspace |
spelling | upm.eprints-1124252025-03-07T01:41:48Z http://psasir.upm.edu.my/id/eprint/112425/ A flow-through optical fibre reflectance sensor for the detection of lead ion based on immobilised gallocynine Yusof, Nor Azah Ahmad, Musa A flow-through spectrophotometric sensor for the determination of lead at trace level using immobilised gallocynine as the reagent phase is proposed. Gallocynine is physically adsorbed onto XAD-7. This method provided a wide linear range of 1 × 10-1 to 1 × 103 ppm and detection limit of 0.06 ppm. This method also showed a reproducible result with relative standard deviation (R.S.D.) of 1.64% and response time of ∼5 min. The response towards lead was also reversible using acidified KNO3 as the regenerating solution. Interference studies showed that Hg(II) and Ag(I) significantly interfered during the determination. Elsevier 2003 Article PeerReviewed text en http://psasir.upm.edu.my/id/eprint/112425/3/112425.pdf Yusof, Nor Azah and Ahmad, Musa (2003) A flow-through optical fibre reflectance sensor for the detection of lead ion based on immobilised gallocynine. Sensors and Actuators B: Chemical, 94 (2). pp. 201-209. ISSN 0925-4005; eISSN: 1873-3077 https://linkinghub.elsevier.com/retrieve/pii/S0925400503003447 10.1016/s0925-4005(03)00344-7 |
spellingShingle | Yusof, Nor Azah Ahmad, Musa A flow-through optical fibre reflectance sensor for the detection of lead ion based on immobilised gallocynine |
title | A flow-through optical fibre reflectance sensor for the detection of lead ion based on immobilised gallocynine |
title_full | A flow-through optical fibre reflectance sensor for the detection of lead ion based on immobilised gallocynine |
title_fullStr | A flow-through optical fibre reflectance sensor for the detection of lead ion based on immobilised gallocynine |
title_full_unstemmed | A flow-through optical fibre reflectance sensor for the detection of lead ion based on immobilised gallocynine |
title_short | A flow-through optical fibre reflectance sensor for the detection of lead ion based on immobilised gallocynine |
title_sort | flow through optical fibre reflectance sensor for the detection of lead ion based on immobilised gallocynine |
url | http://psasir.upm.edu.my/id/eprint/112425/3/112425.pdf |
work_keys_str_mv | AT yusofnorazah aflowthroughopticalfibrereflectancesensorforthedetectionofleadionbasedonimmobilisedgallocynine AT ahmadmusa aflowthroughopticalfibrereflectancesensorforthedetectionofleadionbasedonimmobilisedgallocynine AT yusofnorazah flowthroughopticalfibrereflectancesensorforthedetectionofleadionbasedonimmobilisedgallocynine AT ahmadmusa flowthroughopticalfibrereflectancesensorforthedetectionofleadionbasedonimmobilisedgallocynine |