A flow-through optical fibre reflectance sensor for the detection of lead ion based on immobilised gallocynine
A flow-through spectrophotometric sensor for the determination of lead at trace level using immobilised gallocynine as the reagent phase is proposed. Gallocynine is physically adsorbed onto XAD-7. This method provided a wide linear range of 1 × 10-1 to 1 × 103 ppm and detection limit of 0.06 ppm. Th...
Hlavní autoři: | Yusof, Nor Azah, Ahmad, Musa |
---|---|
Médium: | Článek |
Jazyk: | English |
Vydáno: |
Elsevier
2003
|
On-line přístup: | http://psasir.upm.edu.my/id/eprint/112425/3/112425.pdf |
Podobné jednotky
-
Detection of mercury and copper ions using surface plasmon resonance optical sensor.
Autor: Yap, Wing Fen, a další
Vydáno: (2011) -
Fabrication and evaluation of surface plasmon resonance optical sensor for heavy metal ions detection
Autor: Yap, Wing Fen, a další
Vydáno: (2013) -
Utilization of chitosan-based sensor thin films for the detection of lead ion by surface plasmon resonance optical sensor
Autor: Yap, Wing Fen, a další
Vydáno: (2013) -
Detection of water flow movement in oil field by nanocoated polycarbonate optical fibre sensor
Autor: Moslan, Mohd. Shahrizan
Vydáno: (2023) -
Direct photometric determination of lead by manual and flow injection methods with gallocyanine
Autor: Yusof, Nor Azah, a další
Vydáno: (2009)