Impact of kinetic facade design to enhance daylight performance for office building in Cyberjaya Malaysia

Some critical directions of building facade are highly exposed to the sun and it requires a smarter shading device than conventional shading devices that fail to adapt with nature of sun motion may occur during day, month and seasons. In this study, parametric scripts were written to propose six...

Full description

Bibliographic Details
Main Author: Moesas, Omran Subhi
Format: Thesis
Language:English
Published: 2021
Subjects:
Online Access:http://psasir.upm.edu.my/id/eprint/113814/1/113814.pdf
_version_ 1817927989236596736
author Moesas, Omran Subhi
author_facet Moesas, Omran Subhi
author_sort Moesas, Omran Subhi
collection UPM
description Some critical directions of building facade are highly exposed to the sun and it requires a smarter shading device than conventional shading devices that fail to adapt with nature of sun motion may occur during day, month and seasons. In this study, parametric scripts were written to propose six Kinetic facades design to enhance daylight performance followed by theoretical comparison. The case study was selected to be on Stare Central office building in Cyberjaya, Malaysia to be as virtual model which was built in Rhino for the daylight simulation and to conduct physical daylight measurement by Lux meter device to validate the simulation through a comparison between the physical daylighting measurement with the virtual simulation. Parametric Daylight simulation was performed on Rotating Facade design through Rhino software using plugins Grasshopper and Diva with a Radiance interface based on LEED V4.1 criteria. The daylight simulation was divided into four phases, starting with annual simulation for benchmark (the actual existing facade) and different glaze materials followed by simulations for facade parameters (size & rotation angle) ending with the hourly daylight simulation. The annual simulation was conducted using Daylight Dynamic Performance Metrics specifically; Spatial-Daylight-Autonomy (sDA300/50%) and Annual- Sunlight-Exposure (ASE1000/250hr). While the Hourly simulation depend on modified metric which is Hourly Spatial daylight Autonomy HsDA and Hourly sun exposure HSE from 8AM to 6PM in four days that represent the equinox and solstice days. From the results obtained, benchmark cases illustrate the need of highperformance facade to decrease the recorded dangerous values caused by direct sun radiation. none of the glaze materials achieved credit of LEED standards except Generic Translucent panel 20% with 1 credit. The rotation angle 20˚ and 30˚ of rotating façade have achieved three credits of LEED in east and west respectively as a static system. Finally, the study proposed two optimized dynamic systems able to adapt hourly according to the sun position and achieve higher performance than optimum static configure based on comparison.
first_indexed 2024-12-09T02:27:12Z
format Thesis
id upm.eprints-113814
institution Universiti Putra Malaysia
language English
last_indexed 2024-12-09T02:27:12Z
publishDate 2021
record_format dspace
spelling upm.eprints-1138142024-11-27T03:57:37Z http://psasir.upm.edu.my/id/eprint/113814/ Impact of kinetic facade design to enhance daylight performance for office building in Cyberjaya Malaysia Moesas, Omran Subhi Some critical directions of building facade are highly exposed to the sun and it requires a smarter shading device than conventional shading devices that fail to adapt with nature of sun motion may occur during day, month and seasons. In this study, parametric scripts were written to propose six Kinetic facades design to enhance daylight performance followed by theoretical comparison. The case study was selected to be on Stare Central office building in Cyberjaya, Malaysia to be as virtual model which was built in Rhino for the daylight simulation and to conduct physical daylight measurement by Lux meter device to validate the simulation through a comparison between the physical daylighting measurement with the virtual simulation. Parametric Daylight simulation was performed on Rotating Facade design through Rhino software using plugins Grasshopper and Diva with a Radiance interface based on LEED V4.1 criteria. The daylight simulation was divided into four phases, starting with annual simulation for benchmark (the actual existing facade) and different glaze materials followed by simulations for facade parameters (size & rotation angle) ending with the hourly daylight simulation. The annual simulation was conducted using Daylight Dynamic Performance Metrics specifically; Spatial-Daylight-Autonomy (sDA300/50%) and Annual- Sunlight-Exposure (ASE1000/250hr). While the Hourly simulation depend on modified metric which is Hourly Spatial daylight Autonomy HsDA and Hourly sun exposure HSE from 8AM to 6PM in four days that represent the equinox and solstice days. From the results obtained, benchmark cases illustrate the need of highperformance facade to decrease the recorded dangerous values caused by direct sun radiation. none of the glaze materials achieved credit of LEED standards except Generic Translucent panel 20% with 1 credit. The rotation angle 20˚ and 30˚ of rotating façade have achieved three credits of LEED in east and west respectively as a static system. Finally, the study proposed two optimized dynamic systems able to adapt hourly according to the sun position and achieve higher performance than optimum static configure based on comparison. 2021-06 Thesis NonPeerReviewed text en http://psasir.upm.edu.my/id/eprint/113814/1/113814.pdf Moesas, Omran Subhi (2021) Impact of kinetic facade design to enhance daylight performance for office building in Cyberjaya Malaysia. Masters thesis, Universiti Putra Malaysia. Facades - Design and construction Office buildings - Design and construction Daylighting
spellingShingle Facades - Design and construction
Office buildings - Design and construction
Daylighting
Moesas, Omran Subhi
Impact of kinetic facade design to enhance daylight performance for office building in Cyberjaya Malaysia
title Impact of kinetic facade design to enhance daylight performance for office building in Cyberjaya Malaysia
title_full Impact of kinetic facade design to enhance daylight performance for office building in Cyberjaya Malaysia
title_fullStr Impact of kinetic facade design to enhance daylight performance for office building in Cyberjaya Malaysia
title_full_unstemmed Impact of kinetic facade design to enhance daylight performance for office building in Cyberjaya Malaysia
title_short Impact of kinetic facade design to enhance daylight performance for office building in Cyberjaya Malaysia
title_sort impact of kinetic facade design to enhance daylight performance for office building in cyberjaya malaysia
topic Facades - Design and construction
Office buildings - Design and construction
Daylighting
url http://psasir.upm.edu.my/id/eprint/113814/1/113814.pdf
work_keys_str_mv AT moesasomransubhi impactofkineticfacadedesigntoenhancedaylightperformanceforofficebuildingincyberjayamalaysia