Impact of lightning surge on surge arrester placement in high voltage substation
This study generalizes the modeling details to be used in modeling the high voltage substation and performing the analysis on the impact of lightning surge on surge arrester placement in high voltage substation using the PSCAD/EMTDC software. Modeling parameters and the substation layout design are...
Main Authors: | , |
---|---|
Format: | Article |
Language: | English |
Published: |
Asian Network for Scientific Information
2008
|
Online Access: | http://psasir.upm.edu.my/id/eprint/15107/1/Impact%20of%20lightning%20surge%20on%20surge%20arrester%20placement%20in%20high%20voltage%20substation.pdf |
_version_ | 1796968780294782976 |
---|---|
author | Ab Kadir, Mohd Zainal Abidin Azmi, Aida Maria |
author_facet | Ab Kadir, Mohd Zainal Abidin Azmi, Aida Maria |
author_sort | Ab Kadir, Mohd Zainal Abidin |
collection | UPM |
description | This study generalizes the modeling details to be used in modeling the high voltage substation and performing the analysis on the impact of lightning surge on surge arrester placement in high voltage substation using the PSCAD/EMTDC software. Modeling parameters and the substation layout design are based and adapted from 132 kV substation in Johor Baharu, Malaysia, courtesy of the Tenaga Nasional Berhad (TNB). The model is based on single phase line model as it was suggested by the IEEE to be adequate to represent the substation in transient analysis simulation. The outcome of this paper would be the results of prediction of the breakdown current and effect of surge arrester placement in terms of voltage level measured at particular points in substation. |
first_indexed | 2024-03-06T07:33:22Z |
format | Article |
id | upm.eprints-15107 |
institution | Universiti Putra Malaysia |
language | English |
last_indexed | 2024-03-06T07:33:22Z |
publishDate | 2008 |
publisher | Asian Network for Scientific Information |
record_format | dspace |
spelling | upm.eprints-151072019-05-09T01:24:42Z http://psasir.upm.edu.my/id/eprint/15107/ Impact of lightning surge on surge arrester placement in high voltage substation Ab Kadir, Mohd Zainal Abidin Azmi, Aida Maria This study generalizes the modeling details to be used in modeling the high voltage substation and performing the analysis on the impact of lightning surge on surge arrester placement in high voltage substation using the PSCAD/EMTDC software. Modeling parameters and the substation layout design are based and adapted from 132 kV substation in Johor Baharu, Malaysia, courtesy of the Tenaga Nasional Berhad (TNB). The model is based on single phase line model as it was suggested by the IEEE to be adequate to represent the substation in transient analysis simulation. The outcome of this paper would be the results of prediction of the breakdown current and effect of surge arrester placement in terms of voltage level measured at particular points in substation. Asian Network for Scientific Information 2008 Article PeerReviewed text en http://psasir.upm.edu.my/id/eprint/15107/1/Impact%20of%20lightning%20surge%20on%20surge%20arrester%20placement%20in%20high%20voltage%20substation.pdf Ab Kadir, Mohd Zainal Abidin and Azmi, Aida Maria (2008) Impact of lightning surge on surge arrester placement in high voltage substation. Journal of Applied Sciences, 8 (18). pp. 3298-3301. ISSN 1812-5654; ESSN: 1812-5662 https://scialert.net/abstract/?doi=jas.2008.3298.3301 10.3923/jas.2008.3298.3301 |
spellingShingle | Ab Kadir, Mohd Zainal Abidin Azmi, Aida Maria Impact of lightning surge on surge arrester placement in high voltage substation |
title | Impact of lightning surge on surge arrester placement in high voltage substation |
title_full | Impact of lightning surge on surge arrester placement in high voltage substation |
title_fullStr | Impact of lightning surge on surge arrester placement in high voltage substation |
title_full_unstemmed | Impact of lightning surge on surge arrester placement in high voltage substation |
title_short | Impact of lightning surge on surge arrester placement in high voltage substation |
title_sort | impact of lightning surge on surge arrester placement in high voltage substation |
url | http://psasir.upm.edu.my/id/eprint/15107/1/Impact%20of%20lightning%20surge%20on%20surge%20arrester%20placement%20in%20high%20voltage%20substation.pdf |
work_keys_str_mv | AT abkadirmohdzainalabidin impactoflightningsurgeonsurgearresterplacementinhighvoltagesubstation AT azmiaidamaria impactoflightningsurgeonsurgearresterplacementinhighvoltagesubstation |