Monitoring peroxide value in oxidized emulsions by Fourier transform infrared spectroscopy
Soybean oil (SBO) was blended with 10-40% palm kernel olein (PKO) to obtain SBO:PKO blends with different degrees of unsaturation. Oil-in-water (O/W) emulsions were then prepared with 70 wt-% of SBO or SBO:PKO blends and monitored for their chemical destabilization after an accelerated oxidation pro...
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English English |
Published: |
2005
|
Subjects: | |
Online Access: | http://psasir.upm.edu.my/id/eprint/18342/1/Monitoring%20peroxide%20value%20in%20oxidized%20emulsions%20by%20Fourier%20transform%20infrared%20spectroscopy.pdf |
_version_ | 1825946175025446912 |
---|---|
author | Ibrahim, Nor Hayati Che Man, Yaakob Tan, Chin Ping Idris, Nor Aini |
author_facet | Ibrahim, Nor Hayati Che Man, Yaakob Tan, Chin Ping Idris, Nor Aini |
author_sort | Ibrahim, Nor Hayati |
collection | UPM |
description | Soybean oil (SBO) was blended with 10-40% palm kernel olein (PKO) to obtain SBO:PKO blends with different degrees of unsaturation. Oil-in-water (O/W) emulsions were then prepared with 70 wt-% of SBO or SBO:PKO blends and monitored for their chemical destabilization after an accelerated oxidation process up to 12 days at 60°C. The formation rate of hydroperoxides, as demonstrated by peroxide value (PV) evolution, throughout the oxidation period was relatively high for a fully SBO-based emulsion as compared to those with PKO incorporation. Fourier transform infrared (FTIR) spectroscopic method was also performed in parallel with PV determination, providing further information on structural changes of the functional groups due to lipid oxidation in the emulsions. By using a partial least square chemometric method, a developed calibration model that was based on the spectral region between 1800 and 1480 cm-1 was shown to be able to predict the PV in oxidized emulsions over the range of 4-45 meq/kg. With a 'leave-one-out' cross-validation optimization procedure, the calibration model provides a good coefficient of determination of 0.98 and a root mean standard error of cross-validation of 2.09. In general, FTIR spectroscopy is a suitable technique to monitor PV in oxidized emulsions. © 2005 Wiley-VCH Verlag GmbH & Co. KGaA. |
first_indexed | 2024-03-06T07:42:57Z |
format | Article |
id | upm.eprints-18342 |
institution | Universiti Putra Malaysia |
language | English English |
last_indexed | 2024-03-06T07:42:57Z |
publishDate | 2005 |
record_format | dspace |
spelling | upm.eprints-183422015-10-02T01:10:31Z http://psasir.upm.edu.my/id/eprint/18342/ Monitoring peroxide value in oxidized emulsions by Fourier transform infrared spectroscopy Ibrahim, Nor Hayati Che Man, Yaakob Tan, Chin Ping Idris, Nor Aini Soybean oil (SBO) was blended with 10-40% palm kernel olein (PKO) to obtain SBO:PKO blends with different degrees of unsaturation. Oil-in-water (O/W) emulsions were then prepared with 70 wt-% of SBO or SBO:PKO blends and monitored for their chemical destabilization after an accelerated oxidation process up to 12 days at 60°C. The formation rate of hydroperoxides, as demonstrated by peroxide value (PV) evolution, throughout the oxidation period was relatively high for a fully SBO-based emulsion as compared to those with PKO incorporation. Fourier transform infrared (FTIR) spectroscopic method was also performed in parallel with PV determination, providing further information on structural changes of the functional groups due to lipid oxidation in the emulsions. By using a partial least square chemometric method, a developed calibration model that was based on the spectral region between 1800 and 1480 cm-1 was shown to be able to predict the PV in oxidized emulsions over the range of 4-45 meq/kg. With a 'leave-one-out' cross-validation optimization procedure, the calibration model provides a good coefficient of determination of 0.98 and a root mean standard error of cross-validation of 2.09. In general, FTIR spectroscopy is a suitable technique to monitor PV in oxidized emulsions. © 2005 Wiley-VCH Verlag GmbH & Co. KGaA. 2005 Article PeerReviewed application/pdf en http://psasir.upm.edu.my/id/eprint/18342/1/Monitoring%20peroxide%20value%20in%20oxidized%20emulsions%20by%20Fourier%20transform%20infrared%20spectroscopy.pdf Ibrahim, Nor Hayati and Che Man, Yaakob and Tan, Chin Ping and Idris, Nor Aini (2005) Monitoring peroxide value in oxidized emulsions by Fourier transform infrared spectroscopy. European Journal of Lipid Science and Technology, 107 (12). pp. 886-895. ISSN 1438-7697 http://dx.doi.org/10.1002/ejlt.200500241 Emulsions Fourier transform infrared spectroscopy Peroxides doi:10.1002/ejlt.200500241 English |
spellingShingle | Emulsions Fourier transform infrared spectroscopy Peroxides Ibrahim, Nor Hayati Che Man, Yaakob Tan, Chin Ping Idris, Nor Aini Monitoring peroxide value in oxidized emulsions by Fourier transform infrared spectroscopy |
title | Monitoring peroxide value in oxidized emulsions by Fourier transform infrared spectroscopy |
title_full | Monitoring peroxide value in oxidized emulsions by Fourier transform infrared spectroscopy |
title_fullStr | Monitoring peroxide value in oxidized emulsions by Fourier transform infrared spectroscopy |
title_full_unstemmed | Monitoring peroxide value in oxidized emulsions by Fourier transform infrared spectroscopy |
title_short | Monitoring peroxide value in oxidized emulsions by Fourier transform infrared spectroscopy |
title_sort | monitoring peroxide value in oxidized emulsions by fourier transform infrared spectroscopy |
topic | Emulsions Fourier transform infrared spectroscopy Peroxides |
url | http://psasir.upm.edu.my/id/eprint/18342/1/Monitoring%20peroxide%20value%20in%20oxidized%20emulsions%20by%20Fourier%20transform%20infrared%20spectroscopy.pdf |
work_keys_str_mv | AT ibrahimnorhayati monitoringperoxidevalueinoxidizedemulsionsbyfouriertransforminfraredspectroscopy AT chemanyaakob monitoringperoxidevalueinoxidizedemulsionsbyfouriertransforminfraredspectroscopy AT tanchinping monitoringperoxidevalueinoxidizedemulsionsbyfouriertransforminfraredspectroscopy AT idrisnoraini monitoringperoxidevalueinoxidizedemulsionsbyfouriertransforminfraredspectroscopy |