Aseptic loosening of femoral components - materials engineering and design considerations

Aseptic loosening is one of the main reasons for the revision of a total knee replacement (TKR). The design of the key component of a TKR, the femoral component, is particularly problematic because its failure can be the result of different causes. This makes the development of new biomaterials for...

Full description

Bibliographic Details
Main Authors: Bahraminasab, Marjan, Sahari, Barkawi, Edwards, Kevin L., Farahmand, Farzam, Arumugam, Manohar
Format: Article
Language:English
Published: Elsevier 2013
Online Access:http://psasir.upm.edu.my/id/eprint/28766/1/Aseptic%20loosening%20of%20femoral%20components.pdf
_version_ 1825947380413890560
author Bahraminasab, Marjan
Sahari, Barkawi
Edwards, Kevin L.
Farahmand, Farzam
Arumugam, Manohar
author_facet Bahraminasab, Marjan
Sahari, Barkawi
Edwards, Kevin L.
Farahmand, Farzam
Arumugam, Manohar
author_sort Bahraminasab, Marjan
collection UPM
description Aseptic loosening is one of the main reasons for the revision of a total knee replacement (TKR). The design of the key component of a TKR, the femoral component, is particularly problematic because its failure can be the result of different causes. This makes the development of new biomaterials for use in the femoral component a challenging task. This paper focuses on the engineering design aspects in order to understand the limitations of current materials and design deficiencies. The paper describes the introduction of a new biomaterial for a femoral component and justifies the recommendation to use multi-functional materials as a possible solution to aseptic loosening. The potential advantages of applying functionally graded biomaterials (FGBMs) in prosthetic femur are explained by reducing the leading causes of failure including wear, micro-motion and stress-shielding effect. The ideas presented in this paper can be used as the basis for further research on the feasibility and advantages of applying FGBM in other superior implant designs.
first_indexed 2024-03-06T08:12:29Z
format Article
id upm.eprints-28766
institution Universiti Putra Malaysia
language English
last_indexed 2024-03-06T08:12:29Z
publishDate 2013
publisher Elsevier
record_format dspace
spelling upm.eprints-287662015-08-24T02:03:00Z http://psasir.upm.edu.my/id/eprint/28766/ Aseptic loosening of femoral components - materials engineering and design considerations Bahraminasab, Marjan Sahari, Barkawi Edwards, Kevin L. Farahmand, Farzam Arumugam, Manohar Aseptic loosening is one of the main reasons for the revision of a total knee replacement (TKR). The design of the key component of a TKR, the femoral component, is particularly problematic because its failure can be the result of different causes. This makes the development of new biomaterials for use in the femoral component a challenging task. This paper focuses on the engineering design aspects in order to understand the limitations of current materials and design deficiencies. The paper describes the introduction of a new biomaterial for a femoral component and justifies the recommendation to use multi-functional materials as a possible solution to aseptic loosening. The potential advantages of applying functionally graded biomaterials (FGBMs) in prosthetic femur are explained by reducing the leading causes of failure including wear, micro-motion and stress-shielding effect. The ideas presented in this paper can be used as the basis for further research on the feasibility and advantages of applying FGBM in other superior implant designs. Elsevier 2013-02 Article PeerReviewed application/pdf en http://psasir.upm.edu.my/id/eprint/28766/1/Aseptic%20loosening%20of%20femoral%20components.pdf Bahraminasab, Marjan and Sahari, Barkawi and Edwards, Kevin L. and Farahmand, Farzam and Arumugam, Manohar (2013) Aseptic loosening of femoral components - materials engineering and design considerations. Materials & Design, 44. pp. 155-163. ISSN 0261-3069 10.1016/j.matdes.2012.07.066
spellingShingle Bahraminasab, Marjan
Sahari, Barkawi
Edwards, Kevin L.
Farahmand, Farzam
Arumugam, Manohar
Aseptic loosening of femoral components - materials engineering and design considerations
title Aseptic loosening of femoral components - materials engineering and design considerations
title_full Aseptic loosening of femoral components - materials engineering and design considerations
title_fullStr Aseptic loosening of femoral components - materials engineering and design considerations
title_full_unstemmed Aseptic loosening of femoral components - materials engineering and design considerations
title_short Aseptic loosening of femoral components - materials engineering and design considerations
title_sort aseptic loosening of femoral components materials engineering and design considerations
url http://psasir.upm.edu.my/id/eprint/28766/1/Aseptic%20loosening%20of%20femoral%20components.pdf
work_keys_str_mv AT bahraminasabmarjan asepticlooseningoffemoralcomponentsmaterialsengineeringanddesignconsiderations
AT saharibarkawi asepticlooseningoffemoralcomponentsmaterialsengineeringanddesignconsiderations
AT edwardskevinl asepticlooseningoffemoralcomponentsmaterialsengineeringanddesignconsiderations
AT farahmandfarzam asepticlooseningoffemoralcomponentsmaterialsengineeringanddesignconsiderations
AT arumugammanohar asepticlooseningoffemoralcomponentsmaterialsengineeringanddesignconsiderations