Aseptic loosening of femoral components - materials engineering and design considerations
Aseptic loosening is one of the main reasons for the revision of a total knee replacement (TKR). The design of the key component of a TKR, the femoral component, is particularly problematic because its failure can be the result of different causes. This makes the development of new biomaterials for...
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Elsevier
2013
|
Online Access: | http://psasir.upm.edu.my/id/eprint/28766/1/Aseptic%20loosening%20of%20femoral%20components.pdf |
_version_ | 1825947380413890560 |
---|---|
author | Bahraminasab, Marjan Sahari, Barkawi Edwards, Kevin L. Farahmand, Farzam Arumugam, Manohar |
author_facet | Bahraminasab, Marjan Sahari, Barkawi Edwards, Kevin L. Farahmand, Farzam Arumugam, Manohar |
author_sort | Bahraminasab, Marjan |
collection | UPM |
description | Aseptic loosening is one of the main reasons for the revision of a total knee replacement (TKR). The design of the key component of a TKR, the femoral component, is particularly problematic because its failure can be the result of different causes. This makes the development of new biomaterials for use in the femoral component a challenging task. This paper focuses on the engineering design aspects in order to understand the limitations of current materials and design deficiencies. The paper describes the introduction of a new biomaterial for a femoral component and justifies the recommendation to use multi-functional materials as a possible solution to aseptic loosening. The potential advantages of applying functionally graded biomaterials (FGBMs) in prosthetic femur are explained by reducing the leading causes of failure including wear, micro-motion and stress-shielding effect. The ideas presented in this paper can be used as the basis for further research on the feasibility and advantages of applying FGBM in other superior implant designs. |
first_indexed | 2024-03-06T08:12:29Z |
format | Article |
id | upm.eprints-28766 |
institution | Universiti Putra Malaysia |
language | English |
last_indexed | 2024-03-06T08:12:29Z |
publishDate | 2013 |
publisher | Elsevier |
record_format | dspace |
spelling | upm.eprints-287662015-08-24T02:03:00Z http://psasir.upm.edu.my/id/eprint/28766/ Aseptic loosening of femoral components - materials engineering and design considerations Bahraminasab, Marjan Sahari, Barkawi Edwards, Kevin L. Farahmand, Farzam Arumugam, Manohar Aseptic loosening is one of the main reasons for the revision of a total knee replacement (TKR). The design of the key component of a TKR, the femoral component, is particularly problematic because its failure can be the result of different causes. This makes the development of new biomaterials for use in the femoral component a challenging task. This paper focuses on the engineering design aspects in order to understand the limitations of current materials and design deficiencies. The paper describes the introduction of a new biomaterial for a femoral component and justifies the recommendation to use multi-functional materials as a possible solution to aseptic loosening. The potential advantages of applying functionally graded biomaterials (FGBMs) in prosthetic femur are explained by reducing the leading causes of failure including wear, micro-motion and stress-shielding effect. The ideas presented in this paper can be used as the basis for further research on the feasibility and advantages of applying FGBM in other superior implant designs. Elsevier 2013-02 Article PeerReviewed application/pdf en http://psasir.upm.edu.my/id/eprint/28766/1/Aseptic%20loosening%20of%20femoral%20components.pdf Bahraminasab, Marjan and Sahari, Barkawi and Edwards, Kevin L. and Farahmand, Farzam and Arumugam, Manohar (2013) Aseptic loosening of femoral components - materials engineering and design considerations. Materials & Design, 44. pp. 155-163. ISSN 0261-3069 10.1016/j.matdes.2012.07.066 |
spellingShingle | Bahraminasab, Marjan Sahari, Barkawi Edwards, Kevin L. Farahmand, Farzam Arumugam, Manohar Aseptic loosening of femoral components - materials engineering and design considerations |
title | Aseptic loosening of femoral components - materials engineering and design considerations |
title_full | Aseptic loosening of femoral components - materials engineering and design considerations |
title_fullStr | Aseptic loosening of femoral components - materials engineering and design considerations |
title_full_unstemmed | Aseptic loosening of femoral components - materials engineering and design considerations |
title_short | Aseptic loosening of femoral components - materials engineering and design considerations |
title_sort | aseptic loosening of femoral components materials engineering and design considerations |
url | http://psasir.upm.edu.my/id/eprint/28766/1/Aseptic%20loosening%20of%20femoral%20components.pdf |
work_keys_str_mv | AT bahraminasabmarjan asepticlooseningoffemoralcomponentsmaterialsengineeringanddesignconsiderations AT saharibarkawi asepticlooseningoffemoralcomponentsmaterialsengineeringanddesignconsiderations AT edwardskevinl asepticlooseningoffemoralcomponentsmaterialsengineeringanddesignconsiderations AT farahmandfarzam asepticlooseningoffemoralcomponentsmaterialsengineeringanddesignconsiderations AT arumugammanohar asepticlooseningoffemoralcomponentsmaterialsengineeringanddesignconsiderations |