Low cost and wearable multichannel surface electromyography data acquisition system architecture

Electromyography signals is one of the most important studies of muscle function used in wide area including kinesiology, rehabilitation, and occupational and sports medicine. The measurement of electromyogram always requires multichannel as every movement will involve a group of muscles. Commercial...

Full description

Bibliographic Details
Main Authors: Jamaluddin, Nurul Fauzani, Ahmad, Siti Anom, Mohd Noor, Samsul Bahari, Wan Hasan, Wan Zuha
Format: Article
Language:English
Published: School of Engineering, Taylor’s University College 2014
Online Access:http://psasir.upm.edu.my/id/eprint/34401/1/Low%20cost%20and%20wearable%20multichannel%20surface%20electromyography%20data%20acquisition%20system%20architecture.pdf
_version_ 1796972497408622592
author Jamaluddin, Nurul Fauzani
Ahmad, Siti Anom
Mohd Noor, Samsul Bahari
Wan Hasan, Wan Zuha
author_facet Jamaluddin, Nurul Fauzani
Ahmad, Siti Anom
Mohd Noor, Samsul Bahari
Wan Hasan, Wan Zuha
author_sort Jamaluddin, Nurul Fauzani
collection UPM
description Electromyography signals is one of the most important studies of muscle function used in wide area including kinesiology, rehabilitation, and occupational and sports medicine. The measurement of electromyogram always requires multichannel as every movement will involve a group of muscles. Commercial single or multichannel surface electromyogram data acquisition system is very expensive for beginner researcher. Some of the systems are available in bulky device, heavy and not portable. As electromyogram detected once muscle is active and contract, a wearable device is desired since several movement will involve during measurement is taken. Therefore, this paper presents architecture of low cost and wearable multichannel surface electromyogram data acquisition system. It is light weight, low power consumption and using stacking system as numbers of electromyography channels used can be varied based on application.
first_indexed 2024-03-06T08:28:54Z
format Article
id upm.eprints-34401
institution Universiti Putra Malaysia
language English
last_indexed 2024-03-06T08:28:54Z
publishDate 2014
publisher School of Engineering, Taylor’s University College
record_format dspace
spelling upm.eprints-344012016-09-15T07:13:21Z http://psasir.upm.edu.my/id/eprint/34401/ Low cost and wearable multichannel surface electromyography data acquisition system architecture Jamaluddin, Nurul Fauzani Ahmad, Siti Anom Mohd Noor, Samsul Bahari Wan Hasan, Wan Zuha Electromyography signals is one of the most important studies of muscle function used in wide area including kinesiology, rehabilitation, and occupational and sports medicine. The measurement of electromyogram always requires multichannel as every movement will involve a group of muscles. Commercial single or multichannel surface electromyogram data acquisition system is very expensive for beginner researcher. Some of the systems are available in bulky device, heavy and not portable. As electromyogram detected once muscle is active and contract, a wearable device is desired since several movement will involve during measurement is taken. Therefore, this paper presents architecture of low cost and wearable multichannel surface electromyogram data acquisition system. It is light weight, low power consumption and using stacking system as numbers of electromyography channels used can be varied based on application. School of Engineering, Taylor’s University College 2014 Article PeerReviewed application/pdf en http://psasir.upm.edu.my/id/eprint/34401/1/Low%20cost%20and%20wearable%20multichannel%20surface%20electromyography%20data%20acquisition%20system%20architecture.pdf Jamaluddin, Nurul Fauzani and Ahmad, Siti Anom and Mohd Noor, Samsul Bahari and Wan Hasan, Wan Zuha (2014) Low cost and wearable multichannel surface electromyography data acquisition system architecture. Journal of Engineering Science and Technology, 9. pp. 98-106. ISSN 1823-4690 http://jestec.taylors.edu.my/Special%20Issue%20SAES2013.htm
spellingShingle Jamaluddin, Nurul Fauzani
Ahmad, Siti Anom
Mohd Noor, Samsul Bahari
Wan Hasan, Wan Zuha
Low cost and wearable multichannel surface electromyography data acquisition system architecture
title Low cost and wearable multichannel surface electromyography data acquisition system architecture
title_full Low cost and wearable multichannel surface electromyography data acquisition system architecture
title_fullStr Low cost and wearable multichannel surface electromyography data acquisition system architecture
title_full_unstemmed Low cost and wearable multichannel surface electromyography data acquisition system architecture
title_short Low cost and wearable multichannel surface electromyography data acquisition system architecture
title_sort low cost and wearable multichannel surface electromyography data acquisition system architecture
url http://psasir.upm.edu.my/id/eprint/34401/1/Low%20cost%20and%20wearable%20multichannel%20surface%20electromyography%20data%20acquisition%20system%20architecture.pdf
work_keys_str_mv AT jamaluddinnurulfauzani lowcostandwearablemultichannelsurfaceelectromyographydataacquisitionsystemarchitecture
AT ahmadsitianom lowcostandwearablemultichannelsurfaceelectromyographydataacquisitionsystemarchitecture
AT mohdnoorsamsulbahari lowcostandwearablemultichannelsurfaceelectromyographydataacquisitionsystemarchitecture
AT wanhasanwanzuha lowcostandwearablemultichannelsurfaceelectromyographydataacquisitionsystemarchitecture