Study dual open ended coaxial sensor system for calculation of phase using two magnitudes
A dual open ended coaxial sensor system to determine complex permittivity was studied in detail. This paper focuses on determination of a reflection coefficient phase from two magnitudes using modified capacitance model from 300 kHz to 8 GHz. The phase information can then be used for calculation of...
Main Authors: | , , , , |
---|---|
Format: | Article |
Published: |
IEEE Sensors Council
2014
|
_version_ | 1796972722982486016 |
---|---|
author | Lee, Kim Yee Chung, Boon Kuan You, Kok Yeow Cheng, Ee Meng Abbas, Zulkifly |
author_facet | Lee, Kim Yee Chung, Boon Kuan You, Kok Yeow Cheng, Ee Meng Abbas, Zulkifly |
author_sort | Lee, Kim Yee |
collection | UPM |
description | A dual open ended coaxial sensor system to determine complex permittivity was studied in detail. This paper focuses on determination of a reflection coefficient phase from two magnitudes using modified capacitance model from 300 kHz to 8 GHz. The phase information can then be used for calculation of the sample's complex permittivity. Factors such as range and limitation of the model, sample's permittivity, operating frequency, and size of sensor were investigated. Sensitivity of calculated phase with respect to small changes in measured magnitude was carried out. |
first_indexed | 2024-03-06T08:32:32Z |
format | Article |
id | upm.eprints-35507 |
institution | Universiti Putra Malaysia |
last_indexed | 2024-03-06T08:32:32Z |
publishDate | 2014 |
publisher | IEEE Sensors Council |
record_format | dspace |
spelling | upm.eprints-355072016-01-11T03:26:00Z http://psasir.upm.edu.my/id/eprint/35507/ Study dual open ended coaxial sensor system for calculation of phase using two magnitudes Lee, Kim Yee Chung, Boon Kuan You, Kok Yeow Cheng, Ee Meng Abbas, Zulkifly A dual open ended coaxial sensor system to determine complex permittivity was studied in detail. This paper focuses on determination of a reflection coefficient phase from two magnitudes using modified capacitance model from 300 kHz to 8 GHz. The phase information can then be used for calculation of the sample's complex permittivity. Factors such as range and limitation of the model, sample's permittivity, operating frequency, and size of sensor were investigated. Sensitivity of calculated phase with respect to small changes in measured magnitude was carried out. IEEE Sensors Council 2014-01 Article PeerReviewed Lee, Kim Yee and Chung, Boon Kuan and You, Kok Yeow and Cheng, Ee Meng and Abbas, Zulkifly (2014) Study dual open ended coaxial sensor system for calculation of phase using two magnitudes. IEEE Sensors Journal, 14 (1). pp. 129-134. ISSN 1530-437X 10.1109/JSEN.2013.2281416 |
spellingShingle | Lee, Kim Yee Chung, Boon Kuan You, Kok Yeow Cheng, Ee Meng Abbas, Zulkifly Study dual open ended coaxial sensor system for calculation of phase using two magnitudes |
title | Study dual open ended coaxial sensor system for calculation of phase using two magnitudes |
title_full | Study dual open ended coaxial sensor system for calculation of phase using two magnitudes |
title_fullStr | Study dual open ended coaxial sensor system for calculation of phase using two magnitudes |
title_full_unstemmed | Study dual open ended coaxial sensor system for calculation of phase using two magnitudes |
title_short | Study dual open ended coaxial sensor system for calculation of phase using two magnitudes |
title_sort | study dual open ended coaxial sensor system for calculation of phase using two magnitudes |
work_keys_str_mv | AT leekimyee studydualopenendedcoaxialsensorsystemforcalculationofphaseusingtwomagnitudes AT chungboonkuan studydualopenendedcoaxialsensorsystemforcalculationofphaseusingtwomagnitudes AT youkokyeow studydualopenendedcoaxialsensorsystemforcalculationofphaseusingtwomagnitudes AT chengeemeng studydualopenendedcoaxialsensorsystemforcalculationofphaseusingtwomagnitudes AT abbaszulkifly studydualopenendedcoaxialsensorsystemforcalculationofphaseusingtwomagnitudes |