Study dual open ended coaxial sensor system for calculation of phase using two magnitudes

A dual open ended coaxial sensor system to determine complex permittivity was studied in detail. This paper focuses on determination of a reflection coefficient phase from two magnitudes using modified capacitance model from 300 kHz to 8 GHz. The phase information can then be used for calculation of...

Full description

Bibliographic Details
Main Authors: Lee, Kim Yee, Chung, Boon Kuan, You, Kok Yeow, Cheng, Ee Meng, Abbas, Zulkifly
Format: Article
Published: IEEE Sensors Council 2014
_version_ 1796972722982486016
author Lee, Kim Yee
Chung, Boon Kuan
You, Kok Yeow
Cheng, Ee Meng
Abbas, Zulkifly
author_facet Lee, Kim Yee
Chung, Boon Kuan
You, Kok Yeow
Cheng, Ee Meng
Abbas, Zulkifly
author_sort Lee, Kim Yee
collection UPM
description A dual open ended coaxial sensor system to determine complex permittivity was studied in detail. This paper focuses on determination of a reflection coefficient phase from two magnitudes using modified capacitance model from 300 kHz to 8 GHz. The phase information can then be used for calculation of the sample's complex permittivity. Factors such as range and limitation of the model, sample's permittivity, operating frequency, and size of sensor were investigated. Sensitivity of calculated phase with respect to small changes in measured magnitude was carried out.
first_indexed 2024-03-06T08:32:32Z
format Article
id upm.eprints-35507
institution Universiti Putra Malaysia
last_indexed 2024-03-06T08:32:32Z
publishDate 2014
publisher IEEE Sensors Council
record_format dspace
spelling upm.eprints-355072016-01-11T03:26:00Z http://psasir.upm.edu.my/id/eprint/35507/ Study dual open ended coaxial sensor system for calculation of phase using two magnitudes Lee, Kim Yee Chung, Boon Kuan You, Kok Yeow Cheng, Ee Meng Abbas, Zulkifly A dual open ended coaxial sensor system to determine complex permittivity was studied in detail. This paper focuses on determination of a reflection coefficient phase from two magnitudes using modified capacitance model from 300 kHz to 8 GHz. The phase information can then be used for calculation of the sample's complex permittivity. Factors such as range and limitation of the model, sample's permittivity, operating frequency, and size of sensor were investigated. Sensitivity of calculated phase with respect to small changes in measured magnitude was carried out. IEEE Sensors Council 2014-01 Article PeerReviewed Lee, Kim Yee and Chung, Boon Kuan and You, Kok Yeow and Cheng, Ee Meng and Abbas, Zulkifly (2014) Study dual open ended coaxial sensor system for calculation of phase using two magnitudes. IEEE Sensors Journal, 14 (1). pp. 129-134. ISSN 1530-437X 10.1109/JSEN.2013.2281416
spellingShingle Lee, Kim Yee
Chung, Boon Kuan
You, Kok Yeow
Cheng, Ee Meng
Abbas, Zulkifly
Study dual open ended coaxial sensor system for calculation of phase using two magnitudes
title Study dual open ended coaxial sensor system for calculation of phase using two magnitudes
title_full Study dual open ended coaxial sensor system for calculation of phase using two magnitudes
title_fullStr Study dual open ended coaxial sensor system for calculation of phase using two magnitudes
title_full_unstemmed Study dual open ended coaxial sensor system for calculation of phase using two magnitudes
title_short Study dual open ended coaxial sensor system for calculation of phase using two magnitudes
title_sort study dual open ended coaxial sensor system for calculation of phase using two magnitudes
work_keys_str_mv AT leekimyee studydualopenendedcoaxialsensorsystemforcalculationofphaseusingtwomagnitudes
AT chungboonkuan studydualopenendedcoaxialsensorsystemforcalculationofphaseusingtwomagnitudes
AT youkokyeow studydualopenendedcoaxialsensorsystemforcalculationofphaseusingtwomagnitudes
AT chengeemeng studydualopenendedcoaxialsensorsystemforcalculationofphaseusingtwomagnitudes
AT abbaszulkifly studydualopenendedcoaxialsensorsystemforcalculationofphaseusingtwomagnitudes