Computational analysis on upper extremity vein graft: simulation on kinked vein graft

An artery reconstruction in upper extremities is rare performed compared to the artery reconstruction in lower extremities. Primary vascular repair was performed in many cases. As to alleviate vascular occlusion, an interposition vein graft or venous bypass grafting were applied. However, one or mor...

Full description

Bibliographic Details
Main Authors: Yahya, Muhd Nur Rahman, Abu Bakar, Shahriman, Zaaba, Siti Khadijah, Syed Waseem Ahmad, Sharifah Roohi, Wan Ahmad, Wan Khairunizam, Ayob, Mohd Nasir, Ismail, Abdul Halim
Format: Article
Language:English
Published: Elsevier 2012
Online Access:http://psasir.upm.edu.my/id/eprint/37909/1/37909.pdf
_version_ 1825949123654713344
author Yahya, Muhd Nur Rahman
Abu Bakar, Shahriman
Zaaba, Siti Khadijah
Syed Waseem Ahmad, Sharifah Roohi
Wan Ahmad, Wan Khairunizam
Ayob, Mohd Nasir
Ismail, Abdul Halim
author_facet Yahya, Muhd Nur Rahman
Abu Bakar, Shahriman
Zaaba, Siti Khadijah
Syed Waseem Ahmad, Sharifah Roohi
Wan Ahmad, Wan Khairunizam
Ayob, Mohd Nasir
Ismail, Abdul Halim
author_sort Yahya, Muhd Nur Rahman
collection UPM
description An artery reconstruction in upper extremities is rare performed compared to the artery reconstruction in lower extremities. Primary vascular repair was performed in many cases. As to alleviate vascular occlusion, an interposition vein graft or venous bypass grafting were applied. However, one or more the internal diameters of applied vein graft are blocked or severely norrowed due to the kinking failure on saphenous vein graft. The objective of this study is to investigate the blood flow influence on vein graft with kinking failure. The 3-D computational fluid dynamic method was employed to determine velocity, pressure gradient, resistance of blood flow and wall shear stress on the kinked vein graft. We expect that velocity, pressure gradient, resistance of blood flow and wall shear stress on kinked vein graft to behave non-hydraulically compared to an ideal straight graft. Futhermore, a longitudinal impedence modulus (ZL) is expected to be insufficient due to kinking failure on vein graft.
first_indexed 2024-03-06T08:39:44Z
format Article
id upm.eprints-37909
institution Universiti Putra Malaysia
language English
last_indexed 2024-03-06T08:39:44Z
publishDate 2012
publisher Elsevier
record_format dspace
spelling upm.eprints-379092016-04-06T01:21:30Z http://psasir.upm.edu.my/id/eprint/37909/ Computational analysis on upper extremity vein graft: simulation on kinked vein graft Yahya, Muhd Nur Rahman Abu Bakar, Shahriman Zaaba, Siti Khadijah Syed Waseem Ahmad, Sharifah Roohi Wan Ahmad, Wan Khairunizam Ayob, Mohd Nasir Ismail, Abdul Halim An artery reconstruction in upper extremities is rare performed compared to the artery reconstruction in lower extremities. Primary vascular repair was performed in many cases. As to alleviate vascular occlusion, an interposition vein graft or venous bypass grafting were applied. However, one or more the internal diameters of applied vein graft are blocked or severely norrowed due to the kinking failure on saphenous vein graft. The objective of this study is to investigate the blood flow influence on vein graft with kinking failure. The 3-D computational fluid dynamic method was employed to determine velocity, pressure gradient, resistance of blood flow and wall shear stress on the kinked vein graft. We expect that velocity, pressure gradient, resistance of blood flow and wall shear stress on kinked vein graft to behave non-hydraulically compared to an ideal straight graft. Futhermore, a longitudinal impedence modulus (ZL) is expected to be insufficient due to kinking failure on vein graft. Elsevier 2012 Article PeerReviewed application/pdf en http://psasir.upm.edu.my/id/eprint/37909/1/37909.pdf Yahya, Muhd Nur Rahman and Abu Bakar, Shahriman and Zaaba, Siti Khadijah and Syed Waseem Ahmad, Sharifah Roohi and Wan Ahmad, Wan Khairunizam and Ayob, Mohd Nasir and Ismail, Abdul Halim (2012) Computational analysis on upper extremity vein graft: simulation on kinked vein graft. Procedia Engineering, 41. pp. 694-699. ISSN 1877-7058 10.1016/j.proeng.2012.07.231
spellingShingle Yahya, Muhd Nur Rahman
Abu Bakar, Shahriman
Zaaba, Siti Khadijah
Syed Waseem Ahmad, Sharifah Roohi
Wan Ahmad, Wan Khairunizam
Ayob, Mohd Nasir
Ismail, Abdul Halim
Computational analysis on upper extremity vein graft: simulation on kinked vein graft
title Computational analysis on upper extremity vein graft: simulation on kinked vein graft
title_full Computational analysis on upper extremity vein graft: simulation on kinked vein graft
title_fullStr Computational analysis on upper extremity vein graft: simulation on kinked vein graft
title_full_unstemmed Computational analysis on upper extremity vein graft: simulation on kinked vein graft
title_short Computational analysis on upper extremity vein graft: simulation on kinked vein graft
title_sort computational analysis on upper extremity vein graft simulation on kinked vein graft
url http://psasir.upm.edu.my/id/eprint/37909/1/37909.pdf
work_keys_str_mv AT yahyamuhdnurrahman computationalanalysisonupperextremityveingraftsimulationonkinkedveingraft
AT abubakarshahriman computationalanalysisonupperextremityveingraftsimulationonkinkedveingraft
AT zaabasitikhadijah computationalanalysisonupperextremityveingraftsimulationonkinkedveingraft
AT syedwaseemahmadsharifahroohi computationalanalysisonupperextremityveingraftsimulationonkinkedveingraft
AT wanahmadwankhairunizam computationalanalysisonupperextremityveingraftsimulationonkinkedveingraft
AT ayobmohdnasir computationalanalysisonupperextremityveingraftsimulationonkinkedveingraft
AT ismailabdulhalim computationalanalysisonupperextremityveingraftsimulationonkinkedveingraft