New application of rigid polyvinyl chloride pipes in subsurface stormwater storage-infiltration system

Polyvinyl chloride commonly abbreviated PVC is thermoplastic that is a polymer of vinyl chloride. Resins of polyvinyl chloride are hard, but with the addition of plasticizers a flexible plastic can be made. The good performance and low cost of rigid polyvinyl chloride commonly abbreviated PVC-U pr...

Full description

Bibliographic Details
Main Authors: AL-Hamati, Abdullah Ali Nassir, Ghazali, Abdul Halim, Mohammed Ali, Thamer Ahmed, Norzaie, Jamalodin, Abdul Kadir, Mohd. Razali
Format: Conference or Workshop Item
Language:English
Published: Federation of Engineering Institutions of Islamic Countries 2006
Online Access:http://psasir.upm.edu.my/id/eprint/39741/1/39741.pdf
_version_ 1796973599623479296
author AL-Hamati, Abdullah Ali Nassir
Ghazali, Abdul Halim
Mohammed Ali, Thamer Ahmed
Norzaie, Jamalodin
Abdul Kadir, Mohd. Razali
author_facet AL-Hamati, Abdullah Ali Nassir
Ghazali, Abdul Halim
Mohammed Ali, Thamer Ahmed
Norzaie, Jamalodin
Abdul Kadir, Mohd. Razali
author_sort AL-Hamati, Abdullah Ali Nassir
collection UPM
description Polyvinyl chloride commonly abbreviated PVC is thermoplastic that is a polymer of vinyl chloride. Resins of polyvinyl chloride are hard, but with the addition of plasticizers a flexible plastic can be made. The good performance and low cost of rigid polyvinyl chloride commonly abbreviated PVC-U products make this polymer very suitable for many applications. Pipelines in water and sewer systems are the most common applications of PVC-U. Using PVC-U pipes in this study is a new and different from the common applications. The pipes will be used here to sustain axial loads for sub-surface stormwater storage and infiltration purposes. This study was conducted to investigate theoretically and experimentally the behavior and the capability of PVC-U pipes with and without existing of radial holes (orifices) in its wall to sustain the axial loads. Behavior of PVC-U pipes was investigated theoretically by modeling the pipe system using ANSYS Release 9.0 finite element code. The pipe was modeled using Solid 3-D brick element available in the element library of the ANSYS commercial package called SOLID45. The stress concentration around different orifice diameters at different locations from the pipe bottom subjected to an axial compression load of 3.4 kN are calculated. Furthermore, the behavior of PVC-U pipes specimens subjected to short-term uniaxial compression loads were experimentally investigated. Results of the load-displacement tests on pipes of different orifice locations were recorded. The experimental test results show that the PVC-U pipes have a tremendous capability of supporting the axial loads. Existing of radial orifices in the pipe wall will reduce its strength of supporting axial loads by approximately of 14%.. The pipe strength will be reduced also when the radial orifices becomes closer to the loaded pipe end.
first_indexed 2024-03-06T08:45:01Z
format Conference or Workshop Item
id upm.eprints-39741
institution Universiti Putra Malaysia
language English
last_indexed 2024-03-06T08:45:01Z
publishDate 2006
publisher Federation of Engineering Institutions of Islamic Countries
record_format dspace
spelling upm.eprints-397412015-08-20T06:46:23Z http://psasir.upm.edu.my/id/eprint/39741/ New application of rigid polyvinyl chloride pipes in subsurface stormwater storage-infiltration system AL-Hamati, Abdullah Ali Nassir Ghazali, Abdul Halim Mohammed Ali, Thamer Ahmed Norzaie, Jamalodin Abdul Kadir, Mohd. Razali Polyvinyl chloride commonly abbreviated PVC is thermoplastic that is a polymer of vinyl chloride. Resins of polyvinyl chloride are hard, but with the addition of plasticizers a flexible plastic can be made. The good performance and low cost of rigid polyvinyl chloride commonly abbreviated PVC-U products make this polymer very suitable for many applications. Pipelines in water and sewer systems are the most common applications of PVC-U. Using PVC-U pipes in this study is a new and different from the common applications. The pipes will be used here to sustain axial loads for sub-surface stormwater storage and infiltration purposes. This study was conducted to investigate theoretically and experimentally the behavior and the capability of PVC-U pipes with and without existing of radial holes (orifices) in its wall to sustain the axial loads. Behavior of PVC-U pipes was investigated theoretically by modeling the pipe system using ANSYS Release 9.0 finite element code. The pipe was modeled using Solid 3-D brick element available in the element library of the ANSYS commercial package called SOLID45. The stress concentration around different orifice diameters at different locations from the pipe bottom subjected to an axial compression load of 3.4 kN are calculated. Furthermore, the behavior of PVC-U pipes specimens subjected to short-term uniaxial compression loads were experimentally investigated. Results of the load-displacement tests on pipes of different orifice locations were recorded. The experimental test results show that the PVC-U pipes have a tremendous capability of supporting the axial loads. Existing of radial orifices in the pipe wall will reduce its strength of supporting axial loads by approximately of 14%.. The pipe strength will be reduced also when the radial orifices becomes closer to the loaded pipe end. Federation of Engineering Institutions of Islamic Countries 2006 Conference or Workshop Item NonPeerReviewed application/pdf en http://psasir.upm.edu.my/id/eprint/39741/1/39741.pdf AL-Hamati, Abdullah Ali Nassir and Ghazali, Abdul Halim and Mohammed Ali, Thamer Ahmed and Norzaie, Jamalodin and Abdul Kadir, Mohd. Razali (2006) New application of rigid polyvinyl chloride pipes in subsurface stormwater storage-infiltration system. In: Seminar on Engineering and Technology (SET2006) , 4 - 5 Sept. 2006, Putrajaya, Malaysia. (pp. 449-460).
spellingShingle AL-Hamati, Abdullah Ali Nassir
Ghazali, Abdul Halim
Mohammed Ali, Thamer Ahmed
Norzaie, Jamalodin
Abdul Kadir, Mohd. Razali
New application of rigid polyvinyl chloride pipes in subsurface stormwater storage-infiltration system
title New application of rigid polyvinyl chloride pipes in subsurface stormwater storage-infiltration system
title_full New application of rigid polyvinyl chloride pipes in subsurface stormwater storage-infiltration system
title_fullStr New application of rigid polyvinyl chloride pipes in subsurface stormwater storage-infiltration system
title_full_unstemmed New application of rigid polyvinyl chloride pipes in subsurface stormwater storage-infiltration system
title_short New application of rigid polyvinyl chloride pipes in subsurface stormwater storage-infiltration system
title_sort new application of rigid polyvinyl chloride pipes in subsurface stormwater storage infiltration system
url http://psasir.upm.edu.my/id/eprint/39741/1/39741.pdf
work_keys_str_mv AT alhamatiabdullahalinassir newapplicationofrigidpolyvinylchloridepipesinsubsurfacestormwaterstorageinfiltrationsystem
AT ghazaliabdulhalim newapplicationofrigidpolyvinylchloridepipesinsubsurfacestormwaterstorageinfiltrationsystem
AT mohammedalithamerahmed newapplicationofrigidpolyvinylchloridepipesinsubsurfacestormwaterstorageinfiltrationsystem
AT norzaiejamalodin newapplicationofrigidpolyvinylchloridepipesinsubsurfacestormwaterstorageinfiltrationsystem
AT abdulkadirmohdrazali newapplicationofrigidpolyvinylchloridepipesinsubsurfacestormwaterstorageinfiltrationsystem