Positive infusion of propofol drug during induction
Non-opioid intravenous anesthetic agents, such as propofol, have been used in anesthesia since 1970’s for conscious sedation. In this paper, the study aims to regulate the syringe pump of propofol infusion during induction. The syringe pump is regulated by using a linear positive controller. The co...
Main Authors: | , , |
---|---|
Format: | Conference or Workshop Item |
Published: |
IEEE
2010
|
_version_ | 1825949691022409728 |
---|---|
author | Syam, Syafiie Rami, Mustapha Ait Tadeo, Fernando |
author_facet | Syam, Syafiie Rami, Mustapha Ait Tadeo, Fernando |
author_sort | Syam, Syafiie |
collection | UPM |
description | Non-opioid intravenous anesthetic agents, such as
propofol, have been used in anesthesia since 1970’s for conscious sedation. In this paper, the study aims to regulate the syringe pump of propofol infusion during induction. The syringe pump is regulated by using a linear positive controller. The controller is designed so as to satisfy positivity in state. The control output
is positive and bounded. Effect site concentration is used as a feedback to the controller. Simulation results show that the controller regulates propofol very well and the BIS responses of the patient are observed so that there is no overshoot or oscillation. |
first_indexed | 2024-03-06T08:48:27Z |
format | Conference or Workshop Item |
id | upm.eprints-40932 |
institution | Universiti Putra Malaysia |
last_indexed | 2024-03-06T08:48:27Z |
publishDate | 2010 |
publisher | IEEE |
record_format | dspace |
spelling | upm.eprints-409322017-06-06T09:38:46Z http://psasir.upm.edu.my/id/eprint/40932/ Positive infusion of propofol drug during induction Syam, Syafiie Rami, Mustapha Ait Tadeo, Fernando Non-opioid intravenous anesthetic agents, such as propofol, have been used in anesthesia since 1970’s for conscious sedation. In this paper, the study aims to regulate the syringe pump of propofol infusion during induction. The syringe pump is regulated by using a linear positive controller. The controller is designed so as to satisfy positivity in state. The control output is positive and bounded. Effect site concentration is used as a feedback to the controller. Simulation results show that the controller regulates propofol very well and the BIS responses of the patient are observed so that there is no overshoot or oscillation. IEEE 2010 Conference or Workshop Item PeerReviewed Syam, Syafiie and Rami, Mustapha Ait and Tadeo, Fernando (2010) Positive infusion of propofol drug during induction. In: International Conference on Industrial and Engineering Management (IEEM 2010), 7-10 Dec. 2010, Macao. (pp. 325-328). 10.1109/IEEM.2010.5674305 |
spellingShingle | Syam, Syafiie Rami, Mustapha Ait Tadeo, Fernando Positive infusion of propofol drug during induction |
title | Positive infusion of propofol drug during induction |
title_full | Positive infusion of propofol drug during induction |
title_fullStr | Positive infusion of propofol drug during induction |
title_full_unstemmed | Positive infusion of propofol drug during induction |
title_short | Positive infusion of propofol drug during induction |
title_sort | positive infusion of propofol drug during induction |
work_keys_str_mv | AT syamsyafiie positiveinfusionofpropofoldrugduringinduction AT ramimustaphaait positiveinfusionofpropofoldrugduringinduction AT tadeofernando positiveinfusionofpropofoldrugduringinduction |