Consideration of lightning current along a tall structure in the presence of horizontal arrangement grounding

The evaluation of the behaviour of lightning current along a tall structure is becoming an important issue when considering the lightning protection equipment required along a tall structure. This behaviour is affected by the element of the ground reflection factor which has a correlation between th...

Full description

Bibliographic Details
Main Authors: Ab Kadir, Mohd Zainal Abidin, Gomes, Chandima, Azis, Norhafiz, Rameli, Norhidayu, Izadi, Mahdi, Md Arshad @ Hashim, Syahrun Nizam
Format: Article
Language:English
Published: Trans Tech Publications 2015
Online Access:http://psasir.upm.edu.my/id/eprint/44170/1/SOIL.pdf
_version_ 1825929499451064320
author Ab Kadir, Mohd Zainal Abidin
Gomes, Chandima
Azis, Norhafiz
Rameli, Norhidayu
Izadi, Mahdi
Md Arshad @ Hashim, Syahrun Nizam
author_facet Ab Kadir, Mohd Zainal Abidin
Gomes, Chandima
Azis, Norhafiz
Rameli, Norhidayu
Izadi, Mahdi
Md Arshad @ Hashim, Syahrun Nizam
author_sort Ab Kadir, Mohd Zainal Abidin
collection UPM
description The evaluation of the behaviour of lightning current along a tall structure is becoming an important issue when considering the lightning protection equipment required along a tall structure. This behaviour is affected by the element of the ground reflection factor which has a correlation between the impedance of the ground and the tower. The impedance of the ground is considered for a horizontal grounding arrangement while the impedance of the tower is assumed to be constant. Hence, the ground reflection factor can be given a variable value, whereas most of the existing literature assumes a constant value. When a constant value is entered into a calculation field, an inaccurate result is computed.In this paper, the lightning current along a tall structure under varying values of ground reflection factor and including the effect of the presence of a horizontal grounding arrangement has been considered and the results discussed accordingly. Modelling of the lightning return stroke current along a tall structure was undertaken by entering the calculated variable value of the ground reflection factor. The results indicated that a variable value of the ground reflection factor causes different peak values of the current and wave shape of the lightning current for different positions along a tall structure.
first_indexed 2024-03-06T08:57:38Z
format Article
id upm.eprints-44170
institution Universiti Putra Malaysia
language English
last_indexed 2024-03-06T08:57:38Z
publishDate 2015
publisher Trans Tech Publications
record_format dspace
spelling upm.eprints-441702021-01-23T21:10:56Z http://psasir.upm.edu.my/id/eprint/44170/ Consideration of lightning current along a tall structure in the presence of horizontal arrangement grounding Ab Kadir, Mohd Zainal Abidin Gomes, Chandima Azis, Norhafiz Rameli, Norhidayu Izadi, Mahdi Md Arshad @ Hashim, Syahrun Nizam The evaluation of the behaviour of lightning current along a tall structure is becoming an important issue when considering the lightning protection equipment required along a tall structure. This behaviour is affected by the element of the ground reflection factor which has a correlation between the impedance of the ground and the tower. The impedance of the ground is considered for a horizontal grounding arrangement while the impedance of the tower is assumed to be constant. Hence, the ground reflection factor can be given a variable value, whereas most of the existing literature assumes a constant value. When a constant value is entered into a calculation field, an inaccurate result is computed.In this paper, the lightning current along a tall structure under varying values of ground reflection factor and including the effect of the presence of a horizontal grounding arrangement has been considered and the results discussed accordingly. Modelling of the lightning return stroke current along a tall structure was undertaken by entering the calculated variable value of the ground reflection factor. The results indicated that a variable value of the ground reflection factor causes different peak values of the current and wave shape of the lightning current for different positions along a tall structure. Trans Tech Publications 2015 Article PeerReviewed text en http://psasir.upm.edu.my/id/eprint/44170/1/SOIL.pdf Ab Kadir, Mohd Zainal Abidin and Gomes, Chandima and Azis, Norhafiz and Rameli, Norhidayu and Izadi, Mahdi and Md Arshad @ Hashim, Syahrun Nizam (2015) Consideration of lightning current along a tall structure in the presence of horizontal arrangement grounding. Applied Mechanics and Materials, 793. pp. 34-38. ISSN 1660-9336 https://www.scientific.net/AMM.793.34 10.4028/www.scientific.net/AMM.793.34
spellingShingle Ab Kadir, Mohd Zainal Abidin
Gomes, Chandima
Azis, Norhafiz
Rameli, Norhidayu
Izadi, Mahdi
Md Arshad @ Hashim, Syahrun Nizam
Consideration of lightning current along a tall structure in the presence of horizontal arrangement grounding
title Consideration of lightning current along a tall structure in the presence of horizontal arrangement grounding
title_full Consideration of lightning current along a tall structure in the presence of horizontal arrangement grounding
title_fullStr Consideration of lightning current along a tall structure in the presence of horizontal arrangement grounding
title_full_unstemmed Consideration of lightning current along a tall structure in the presence of horizontal arrangement grounding
title_short Consideration of lightning current along a tall structure in the presence of horizontal arrangement grounding
title_sort consideration of lightning current along a tall structure in the presence of horizontal arrangement grounding
url http://psasir.upm.edu.my/id/eprint/44170/1/SOIL.pdf
work_keys_str_mv AT abkadirmohdzainalabidin considerationoflightningcurrentalongatallstructureinthepresenceofhorizontalarrangementgrounding
AT gomeschandima considerationoflightningcurrentalongatallstructureinthepresenceofhorizontalarrangementgrounding
AT azisnorhafiz considerationoflightningcurrentalongatallstructureinthepresenceofhorizontalarrangementgrounding
AT ramelinorhidayu considerationoflightningcurrentalongatallstructureinthepresenceofhorizontalarrangementgrounding
AT izadimahdi considerationoflightningcurrentalongatallstructureinthepresenceofhorizontalarrangementgrounding
AT mdarshadhashimsyahrunnizam considerationoflightningcurrentalongatallstructureinthepresenceofhorizontalarrangementgrounding