Lightning current and voltage distribution of large axially symmetric Buddhist stupa in Sri Lanka
This is one of the first scientific investigations on lightning current and voltage distribution along Buddhist Stupa in Sri Lanka and elsewhere. Such distribution provide vital information on lightning safety concerns of people and objects outside the structure as the building is totally sealed. Th...
المؤلفون الرئيسيون: | Gomes, Chandima, Ab Kadir, Mohd Zainal Abidin, Izadi, Mahdi, Gomes, Ashen |
---|---|
التنسيق: | Conference or Workshop Item |
اللغة: | English |
منشور في: |
IEEE
2014
|
الوصول للمادة أونلاين: | http://psasir.upm.edu.my/id/eprint/44730/1/Lightning%20current%20and%20voltage%20distribution%20of%20large%20axially%20symmetric%20Buddhist%20stupa%20in%20Sri%20Lanka.pdf |